Pedro Baptista

Dr. Pedro Baptista

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
AMAna Marta
Ana Marta
PBPedro Baptista
Pedro Baptista
JMJoao Heitor Marques
Joao Heitor Marques
DADaniel Almeida
Daniel Almeida
DJDiana José
Diana José
IBIrene Barbosa
Irene Barbosa
Purpose: To analyse the clinical outcome in patients with meibomian gland dysfunction (MGD) who underwent intense pulsed light (IPL) plus low-level light therapy (LLL). Materials and Methods: The prospective non-comparative study included identified by MGD patients with altered interferometry and lower loss area of the meibomian glands (LAMG), who underwent IPL plus LLL, between July 2020 and August 2020. A multimodal assessment was performed before, 2– 3 weeks, and 6 months after treatment. The main outcome was lipid layer thickness (LLT) and the secondary outcomes were the ocular surface disease index (OSDI) score, presence of corneal fluorescein staining (CFS), blink rate (BR), Schirmer test (ST), tear meniscus height (TMH), tear osmolarity (OSM), non-invasive break-up time (NIBUT) and LAMG. Results: This study included 62 eyes of 31 patients, 61.3% female, with a mean age of 66.94± 9.08 years at the time of IPL plus LLL treatment. LLT (< 0.001) grades improved 6 months after treatment. The mean OSDI score improved (p< 0.001) from 45.02± 21.17 (severe symptoms) to 22.35± 17.68 (moderate symptoms) at 2– 3 weeks and 8.24± 17.9.91 (normal) at 6 months after treatment. CFS was identified in 51.6% (32/62) before and in 45.2% (28/62) 6 months (p=0.293) after treatment. ST (p=0.014) grades improved; OSM grades mild worsened (p< 0.001); TMH, NIBUT and LAMG grades did not modify 6 months after treatment. No patient suffered any adverse effects. Conclusion: IPL combined with LLL was effective and safe, improving the lipid layer thickness in MGD and decreasing the level of symptoms.

25 February 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
JMJoao Heitor Marques
Joao Heitor Marques
PBPedro Baptista
Pedro Baptista
AAAna Carolina Abreu
Ana Carolina Abreu
SMSílvia Monteiro
Sílvia Monteiro
MPMaria Do Céu Pinto
Maria Do Céu Pinto
Purpose: To evaluate the indications for pIOL explantation, pIOL survival time, and visual outcomes and access endothelial cell loss (ECL) after explantation. Setting: Ophthalmology Department, Centro Hospitalar Universitário do Porto, Portugal. Design: Retrospective longitudinal study. Methods: A chart review was performed for all consecutive patients who underwent pIOL explantation from January 2010 to December 2019 in a single center. Results: This study included 175 eyes of 112 patients (77% women). The mean pIOL survival was 12.9 ± 4.8 (3.7 to 28.6) years, and the mean follow-up period after explantation was 4.1 ± 3.0 (0.3 to 9.9) years. The most frequent causes for explantation were cataract formation (44.0%, n = 77) and ECL (50.3%, n = 88). During the follow-up period after explantation, the mean ECL rate was 2.27 ± 9.32%/year in the cataract group and −2.14 ± 10.24%/year in the ECL group, reflecting a positive change in cell density in the latter. 8 eyes (4.6%) required a corneal transplant during the follow-up. The mean corrected distance visual acuity was 0.17 ± 0.24 logMAR at the last visit. Conclusions: This study demonstrated that pIOL explantation, after a mean survival time of 13 years, was a safe procedure. The main causes for explantation were cataract formation and ECL. Most patients showed a sustained improvement in visual acuity and endothelial cell density after pIOL explantation, and yet its timing should be ideal to avoid irreversible complications.

1 December 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
PBPedro Baptista
Pedro Baptista
JMJoao Heitor Marques
Joao Heitor Marques
MNMiguel Mesquita Neves
Miguel Mesquita Neves
MGMiguel Gomes
Miguel Gomes
LOLuís Oliveira
Luís Oliveira
Purpose: To describe the anatomical and functional results of the implantation of asymmetric thickness intracorneal ring segments (AS-ICRS) in eyes with keratoconus and asymmetric/irregular astigmatism (type 2 – Duck – and type 3 – Snowman – phenotypes, Fernandez-Vega/Alfonso morphologic Keratoconus classification). Materials and Methods: Retrospective observational study including 19 consecutive patients (21 eyes) with keratoconus who underwent manual implantation of the Keraring® Asymmetric ICRS (AS). Analysis included demographic and clinical data and Pentacam (Oculus®) measurements: topographic astigmatism; topographic flat meridian (K1), steepest meridian (K2) and the maximum keratometric point (Kmax); total root mean square (RMS) and high order RMS (HOA) aberrations and comatic Zernike coefficients (Z31;Z3− 1) at 0º and 90º meridians. Results: Overall mean age was 35.3± 11.7 years and median follow-up was 7.1 months (range 6– 12). At the end of follow-up, a significant improvement from baseline was achieved in both UDVA (0.24± 0.22; p=0.017) and CDVA (0.21± 0.17; p< 0.001). Regarding topographic measurements, the greatest decrease was observed in K2 (2.76± 1.9D; p< 0.001) and astigmatism (1.97± 1.5; p< 0.001). Aberrometry analysis showed a reduction of 1.27± 3.2μm in the total RMS (p=0.085), 0.24± 0.9μm in HOA (p=0.227) and 0.78± 0.5 (p< 0.001) in the 90º component of comatic aberration. The procedure effects in the CDVA, topographic and aberrometric parameters were higher in type 2 cones without statistical significance (p> 0.05 in all). Conclusion: Implantation of the Keraring® Asymmetric ICRS in keratoconus with asymmetric/irregular astigmatism allowed an improvement of several clinical, topographic and aberrometric parameters, with clinical efficacy and safety, with a tendency to a greater effect in the type 2 cones.

1 January 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
NSNisa Silva
Nisa Silva
AFAndré Ferreira
André Ferreira
PBPedro Baptista
Pedro Baptista
AFAna Figueiredo
Ana Figueiredo
RRRita Reis
Rita Reis
MMMaria João Menéres
Maria João Menéres
Background: To evaluate biomechanical parameters of the cornea provided by Corvis ST in patients with ocular hypertension, primary open-angle glaucoma, and amyloidotic glaucoma and to compare with healthy controls. Methods: This was a cross-sectional study of patients with ocular hypertension, primary open-angle glaucoma, and amyloidotic glaucoma that underwent Corvis ST imaging. Primary outcome was the comparison of corneal biomechanical parameters between study groups after adjusting for age, gender, Goldmann intraocular pressure (GAT-IOP), and prostaglandin analogues medication. Secondary outcome was the comparison of different TOP measurements in each group. Results: One hundred and eighty-three eyes from 115 patients were included: 61 with primary open-angle glaucoma, 32 with amyloidotic glaucoma, 37 with ocular hypertension and 53 were healthy controls. Amyloidotic glaucoma group had smaller radius (p=0.025), lower deflection amplitude at highest concavity (p=0.019), and higher integrated radius (p=0.014) than controls. Ocular hypertension group had higher stiffness parameter at first applanation (p=0.043) than those with primary open-angle glaucoma, and higher stress-strain index (p=0.049) than those with amyloidotic glaucoma. Biomechanically corrected intraocular pressure was significantly lower than Goldmann intraocular pressure in group with primary open-angle glaucoma (p=0.005) and control group (p=0.013), and Goldmann intraocular pressure adjusted for pachymetry in group with primary open-angle glaucoma (p=0.01). Conclusion: Eyes with amyloidotic glaucoma have more deformable corneas, while eyes with ocular hypertension have less deformable corneas. These findings may be linked to the susceptibility to glaucomatous damage and progression. There were significant differences between Goldmann applanation tonometry and biomechanically corrected intraocular ocular pressure provided by Corvis ST.

1 April 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
PBPedro Baptista
Pedro Baptista
RARENATO AMBROSIO
RENATO AMBROSIO
LOLuis Oliveira
Luis Oliveira
PMPedro Menéres
Pedro Menéres
JBJoao Melo Beirao
Joao Melo Beirao
Background: In recent years, increasing interest has arisen in the application of data from corneal biomechanics in many areas of ophthalmology, particularly to assist in the detection of early corneal ectasia or ectasia susceptibility, to predict corneal response to surgical or therapeutic interventions and in glaucoma management. Technology has evolved and, recently, the Scheimpflug principle was associated with a non-contact air-puff tonometer, allowing a thorough analysis of corneal biomechanics and a biomechanically corrected intraocular pressure assessment, opening up new perspectives both in ophthalmology and in other medical areas. Data from corneal biomechanics assessment are being integrated in artificial intelligence models in order to increase its value in clinical practice. Objective: To review the state of the art in the field of corneal biomechanics assessment with special emphasis to the technology based on ultra-high-speed Scheimpflug imaging during non-contact tonometry. Summary: A meticulous literature review was performed until the present day. We used 136 published manuscripts as our references. Both information from healthy individuals and descriptions of possible associations with systemic diseases are described. Additionally, it exposed information regarding several fields of ocular pathology, from cornea and ocular surface through areas of refractive surgery and glaucoma until vascular and structural diseases of the chorioretinal unit.

23 November 2018 in Ophthalmic Research
Verified
Journal Article
Closed access
PDF file
BPBernardete Pessoa
Bernardete Pessoa
DDDavid Afonso Dias
David Afonso Dias
PBPedro Baptista
Pedro Baptista
CCConstança Coelho
Constança Coelho
JBJoão Nuno Melo Beirão
João Nuno Melo Beirão
AMAngelina Meireles
Angelina Meireles
Purpose: To evaluate pars plana vitrectomy (PPV) outcomes in cases with tractional diabetic macular edema (tDME). Methods: We conducted a single-center retrospective study with a follow-up of 12 months. Forty-six eyes with tDME of 38 patients submitted to PPV between 2013 and 2015 were assessed. A standard PPV was performed and surgical outcomes were registered at the 3-, 6-, and 12-month follow-up. Results: The baseline median best corrected visual acuity (BCVA) in ETDRS (Early Treatment Diabetic Retinopathy Study) letters and the median central foveal thickness (CFT) were 43.0 letters and 491.0 µm, respectively. At the 12-month follow-up, a median decrease in CFT of 232.7 µm was observed. A CFT < 300 µm was achieved in 65.2% of the cases (52.2% needing no further treatment); a BCVA improvement by ≥10 letters was achieved in 60.0%, but there was a decrease of ≥10 letters in 13.0% of the cases. DME recurrence was observed in 10.9% of the cases, with a median time of development after vitrectomy of 6 months. As a major postoperative complication, a macular hole was observed in 1 patient (2.1%). Conclusions: In our series, PPV for tDME induced an improvement in retinal thickening and visual outcome in more than 50% of the cases, with low recurrence rates and a low number of postoperative complications.