Pedro Menéres

Prof. Dr. Pedro Menéres

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Survey of Ophthalmology
Verified
Journal Article
Closed access
RJRafael José-Vieira
Rafael José-Vieira
AFAndré Ferreira
André Ferreira
PMPedro Menéres
Pedro Menéres
BSBernardo Sousa-Pinto
Bernardo Sousa-Pinto
LFLuís Figueira
Luís Figueira

1 February 2018 in International Medical Case Reports Journal
Verified
Journal Article
Open access
PDF file
AAAna Carolina Abreu
Ana Carolina Abreu
LMLuisa Malheiro
Luisa Malheiro
JCJoão Coelho
João Coelho
MNMiguel Mesquita Neves
Miguel Mesquita Neves
MGMiguel Gomes
Miguel Gomes
PMPedro Menéres
Pedro Menéres
Purpose: To analyze the long-term outcomes of intracorneal ring segments (ICRS) implantation for keratoconus management in pediatric patients. Methods: Retrospective case series review of the long-term (>5 years) outcomes of Intacs® ICRS implantation for keratoconus in pediatric patients (age <18 years old at the time of surgery) between January 2008 and December 2011 at Ophthalmology Department of Hospital de Santo António. Demographic data, follow-up time, preoperative and postoperative uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA) in decimal scale, and corneal topography were evaluated. Statistical analysis was done using SPSS for windows (version 24). Significance was set at p<0.0125. Results: Fourteen eyes of 14 patients, with a mean age of 15.36 years (range 10–18 years), were included in this study. All patients had been diagnosed with keratoconus with reported progression in the 6 months prior to surgery. Follow-up time was 6.36±0.97 years. UCVA and BCVA improved after ICRS implantation (p<0.0125). Keratometry (K) minimum (Kmin) and K maximum (Kmax) decreased after surgery (p<0.0125). During follow-up, UCVA, BCVA, Kmin, and Kmax values ranged, showing a tendency to worsen at the end of follow-up. However, statistically significant differences were not observed. Conclusion: ICRS implantation showed good visual and topographic results in pediatric patients. Long-term follow-up suggests that, despite ICRS implantation, there is still progression of keratoconus. To the best of our knowledge, there are no reports regarding the long-term efficacy of ICRS implantation in pediatric patients.

1 April 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
PBPedro Baptista
Pedro Baptista
RARENATO AMBROSIO
RENATO AMBROSIO
LOLuis Oliveira
Luis Oliveira
PMPedro Menéres
Pedro Menéres
JBJoao Melo Beirao
Joao Melo Beirao
Background: In recent years, increasing interest has arisen in the application of data from corneal biomechanics in many areas of ophthalmology, particularly to assist in the detection of early corneal ectasia or ectasia susceptibility, to predict corneal response to surgical or therapeutic interventions and in glaucoma management. Technology has evolved and, recently, the Scheimpflug principle was associated with a non-contact air-puff tonometer, allowing a thorough analysis of corneal biomechanics and a biomechanically corrected intraocular pressure assessment, opening up new perspectives both in ophthalmology and in other medical areas. Data from corneal biomechanics assessment are being integrated in artificial intelligence models in order to increase its value in clinical practice. Objective: To review the state of the art in the field of corneal biomechanics assessment with special emphasis to the technology based on ultra-high-speed Scheimpflug imaging during non-contact tonometry. Summary: A meticulous literature review was performed until the present day. We used 136 published manuscripts as our references. Both information from healthy individuals and descriptions of possible associations with systemic diseases are described. Additionally, it exposed information regarding several fields of ocular pathology, from cornea and ocular surface through areas of refractive surgery and glaucoma until vascular and structural diseases of the chorioretinal unit.

1 January 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
NSNisa Silva
Nisa Silva
AFAndré Ferreira
André Ferreira
PBPedro Baptista
Pedro Baptista
AFAna Figueiredo
Ana Figueiredo
RRRita Reis
Rita Reis
MMMaria João Menéres
Maria João Menéres
Background: To evaluate biomechanical parameters of the cornea provided by Corvis ST in patients with ocular hypertension, primary open-angle glaucoma, and amyloidotic glaucoma and to compare with healthy controls. Methods: This was a cross-sectional study of patients with ocular hypertension, primary open-angle glaucoma, and amyloidotic glaucoma that underwent Corvis ST imaging. Primary outcome was the comparison of corneal biomechanical parameters between study groups after adjusting for age, gender, Goldmann intraocular pressure (GAT-IOP), and prostaglandin analogues medication. Secondary outcome was the comparison of different TOP measurements in each group. Results: One hundred and eighty-three eyes from 115 patients were included: 61 with primary open-angle glaucoma, 32 with amyloidotic glaucoma, 37 with ocular hypertension and 53 were healthy controls. Amyloidotic glaucoma group had smaller radius (p=0.025), lower deflection amplitude at highest concavity (p=0.019), and higher integrated radius (p=0.014) than controls. Ocular hypertension group had higher stiffness parameter at first applanation (p=0.043) than those with primary open-angle glaucoma, and higher stress-strain index (p=0.049) than those with amyloidotic glaucoma. Biomechanically corrected intraocular pressure was significantly lower than Goldmann intraocular pressure in group with primary open-angle glaucoma (p=0.005) and control group (p=0.013), and Goldmann intraocular pressure adjusted for pachymetry in group with primary open-angle glaucoma (p=0.01). Conclusion: Eyes with amyloidotic glaucoma have more deformable corneas, while eyes with ocular hypertension have less deformable corneas. These findings may be linked to the susceptibility to glaucomatous damage and progression. There were significant differences between Goldmann applanation tonometry and biomechanically corrected intraocular ocular pressure provided by Corvis ST.

1 March 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
NSNisa Silva
Nisa Silva
CCCatarina Castro
Catarina Castro
FCFilipa Caiado
Filipa Caiado
SMSofia Maia
Sofia Maia
VMVasco Miranda
Vasco Miranda
PMPedro Menéres
Pedro Menéres
Background: Understanding how strabismus impacts a child’s quality of life, as well as their families, should be an important key to guide treatment, not only from the ophthalmological point of view but also regarding psychological and social aspects, which are fundamental for a healthy and harmonious development. Methods: A cross-sectional study was performed to evaluate the functional vision and eye-related quality of life (ER-QOL) in a population of children with strabismus submitted or not to corrective surgery, using the recently developed Pediatric Eye Questionnaire (PedEyeQ) and to compare with age and gender-matched visually normal children. The PedEyeQ was applied to non-operated children with strabismus (n = 18), operated children with strabismus (n = 24), and visually normal children (n = 21). This instrument is composed of 3 components (Child, Proxy, and Parent) and has different versions according to the child’s age (0– 4, 5– 11, or 12– 17 years-old versions). Clinical data such as age, type of strabismus, angle of deviation, amblyopia, occlusion treatment, and surgical outcome were also recorded. Results: All PedEyeQ domain scores were significantly lower in children with strabismus compared with visually normal children, except the Child “functional vision” domain. Children with strabismus with successful corrective surgery had significantly lower scores in many domains of the Child, Proxy, and Parent components, compared with visually normal children. Conclusion: This study showed that strabismus has an important impact on affected children and their families, as assessed by PedEyeQ. Interestingly, children with prior successful corrective strabismus surgery had worse PedEyeQ scores compared to visually normal children. Educational programs and psychosocial rehabilitation interventions should be implemented in children with strabismus and their families.

1 January 2016 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
CVCarolina Vale
Carolina Vale
CMCarlos Menezes
Carlos Menezes
JFJ. Firmino-Machado
J. Firmino-Machado
PRPedro Rodrigues
Pedro Rodrigues
PTPaula Tenedório
Paula Tenedório
MLMiguel Lume
Miguel Lume
Purpose: The purpose of this study was to evaluate the visual and refractive outcomes and rotational stability of the new aspheric Precizon® toric intraocular lens (IOL) for the correction of corneal astigmatism in cataract surgery. Setting: Department of Ophthalmology, Hospital Geral de Santo António – Centro Hospitalar do Porto, EPE and Hospital de Pedro Hispano, Matosinhos, Portugal. Design: This was a prospective clinical study. Patients and methods: A total of 40 eyes of 27 patients with corneal astigmatism greater than 1.0 diopter (D) underwent cataract surgery with implantation of Precizon® toric IOL. IOL power calculation was performed using optical coherence biometry (IOLMaster®). Outcomes of uncorrected (UDVA) and best-spectacle corrected distance visual acuities (BCDVA), refraction, and IOL rotation were analyzed at the 1st week, 1st, 3rd, and 6th month’s evaluations. Results: The median postoperative UDVA was better than preoperative best-spectacle corrected distance visual acuity (0.02 [0.06] logMAR vs 0.19 [0.20] logMAR, P<0.001). At 6 months, postoperative UDVA was 0.1 logMAR or better in 95% of the eyes. At last follow-up, the mean spherical equivalent was reduced from -3.35±3.10 D to -0.02±0.30 D (P<0.001) with 97.5% of the eyes within ±0.50 D of emmetropia. The mean preoperative keratometric cylinder was 2.34±0.95 D and the mean postoperative refractive cylinder was 0.24±0.27 D (P<0.001). The mean IOL rotation was 2.43°±1.55°. None of the IOLs required realignment. Conclusion: Precizon® toric IOL revealed very good rotational stability and performance regarding predictability, efficacy, and safety in the correction of preexisting regular corneal astigmatism associated with cataract surgery.