Walid Al-zordk

Dr. Walid Al-zordk

Associate professor
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2020 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
WAWalid Al-zordk
Walid Al-zordk
AEAhmed Elmisery
Ahmed Elmisery
MGMohamed Ghazy
Mohamed Ghazy
Purpose: To evaluate the tightening torque maintenance with zirconia, lithium disilicate, and polyetheretherketone (PEEK) hybrid-abutment-crowns after thermal aging, in addition to assess the fracture resistance of hybrid-abutment-crowns fabricated with different materials.Materials and methods: Thirty implants were restored with identical hybrid-abutment-crowns, resembling the maxillary first premolar, fabricated from zirconia (Zr), lithium disilicate (L2), or ceramic-reinforced PEEK (PE). The three groups (n= 10) were constructed utilizing a Ti-base. After bonding, each restoration was secured in its respective implant with a torque of 25 Ncm. All restorations were subjected to thermal aging for 7000 cycles. The loosening torque was assessed utilizing the digital torque meter. Each restoration was subjected to fracture testing and the mode of failure was determined.Results: Zr group displayed the highest mean torque loss value (2.70 ± 0.59 Ncm) with the mean loosening torque value of 22.38 ± 0.68 Ncm. PE group displayed the lowest mean torque loss (2.55 ± 0.50 Ncm) with mean loosening torque value of 22.61 ± 0.59 Ncm. There was no significant difference between study groups regarding loosening torque (p= 0.68), torque loss (p= 0.80), and percentage of torque loss (p= 0.79). There was significant difference regarding the mean fracture load value between Zr and PE groups. However, there was no significant difference (p= 0.05) regarding mean fracture load value between L2 and PE groups.Conclusion: The hybrid-abutment-crown material does not affect the torque maintenance after thermal aging. Based on fracture load, zirconia hybrid-abutment-crown can be used, while lithium disilicate and PEEK hybrid-abutment-crowns may cautiously serve in premolar region.

1 December 2020 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
WAWalid Al-zordk
Walid Al-zordk
SSSamah Saker
Samah Saker

28 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
WAWalid Al-zordk
Walid Al-zordk
Alaa Esmaeil SaudiAlaa Esmaeil Saudi
Alaa Esmaeil Saudi
AAAbdelraheem Mohammed Abdelkader
Abdelraheem Mohammed Abdelkader
MTMansoura Taher
Mansoura Taher
MGMohamed Hamed Ghazy
Mohamed Hamed Ghazy
This study assesses the effect of the material type (lithium disilicate, zirconia, and polymer-infiltrated ceramic) and dental bonding substrates (dentin, dentin with intra-coronal cavity, and dentin with composite filling) on the fracture resistance and failure mode of molars restored by occlusal veneers. Methods: Ninety occlusal veneers, fabricated from either lithium disilicate, zirconia, or polymer-infiltrated ceramic, were adhesively bonded to teeth prepared with either dentin, dentin with intra-coronal cavity, or dentin with composite filling. All specimens were thermally aged (5000 cycles), then load cycled (120,000 cycles). Each specimen was subjected to a compressive load through fracture, then was examined (×20) to identify the fracture type. Data were statistically analyzed. Results: Material type and dental substrate had no significant effect on the fracture resistance of adhesively retained occlusal veneer restorations. For each material, no significant differences were found between veneers bonded to dentin, dentin with intra-coronal cavity, and dentin with composite filling. Additionally, within each bonding substrate, there were no significant differences between lithium disilicate, zirconia, and polymer-infiltrated ceramic veneers. The adhesive failure was recorded mainly with zirconia occlusal veneer restorations. Conclusions: Considering the fracture results, lithium disilicate, zirconia, and polymer-infiltrated ceramic occlusal veneers perform well whatever the type of dental bonding surface. When the dental bonding surface varies, different occlusal veneer materials should be considered. Occlusal veneers bonded to dentin, dentin with composite filling, or dentin with an intra-coronal cavity exhibited a fracture resistance exceeding the average human masticatory forces in the molar area.

5 September 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
STShaima Tyor
Shaima Tyor
WAWalid Al-zordk
Walid Al-zordk
ASAmal Sakrana
Amal Sakrana
Objectives: Successful ceramic restorations depend on the strong bonding with resin cement and even stress distribution. The aim of this study was to evaluate the impact of adding MDP-containing zirconia primer before self-adhesive resin cements with different functional acidic monomers on fracture resistance of monolithic zirconia crown. Materials and methods: Eighty defect-free human maxillary premolars were divided according to the cement type and application of MDP-containing zirconia primer into eight groups (n = 10): Calibra Universal (C), Calibra Universal combined with zirconia primer (CZ), RelyX U200 (R), RelyXU200 combined with zirconia primer (RZ), Panavia SA Cement Plus (P), Panavia SA Cement Plus combined with zirconia primer (PZ), Multilink Speed (M), and Multilink Speed combined with zirconia primer (MZ). After teeth preparation and fabrication of zirconia crowns, each crown was bonded to its corresponding tooth. All specimens were subjected to 10,000 thermocycles between 5 and 55°C, followed by cyclic load (50 N) for 240,000 cycles. Each specimen was subjected to a static axial load until fracture using universal testing machine and the fracture load was recorded. The fracture mode studied and recorded. The fracture load results were analyzed using two-way ANOVA test (α = 0.05). Results: A significant interaction (P = 0.038) of combining MDP-containing zirconia primer and cement type on fracture resistance of monolithic zirconia crown was detected. The mean fracture load values of zirconia crown were significantly influenced by the combined application of the MDP-containing zirconia primer with Calibra Universal (P = 0.01), RelyX U200 (P < 0.001), and Multilink Speed (P = 0.038), while there was no significant difference with Panavia SA Cement Plus (P = 0.660). There was significant difference (F = 20.69, P < 0.001) between the mean fracture loads of groups with self-adhesive cements (C, R, P, and M groups). The highest fracture load was recorded with RZ group (2446.90 ± 126.72 N) while the lowest fracture load was recorded with C group (1623.18 ± 149.86 N). Conclusions: The self-adhesive resin cement with different acidic functional monomer affects the fracture resistance of monolithic zirconia crown. Application of MDP-containing primer could improve the fracture resistance of monolithic zirconia crown with most self-adhesive cements. The application of an MDP-containing primer had no impact on the fracture resistance of monolithic translucent zirconia crown bonded by MDP-containing self-adhesive resin cement.

25 February 2023 in Journal of Prosthodontics
Verified
Journal Article
Closed access
MEMohammed Elsherbini
Mohammed Elsherbini
ASAmal Sakrana
Amal Sakrana
RARahma A Amin
Rahma A Amin
MDMohamed Diaa
Mohamed Diaa
MÖMutlu Özcan
Mutlu Özcan
WAWalid Al-zordk
Walid Al-zordk

6 March 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AEAhmed Elsherbini Elazazy Elshal
Ahmed Elsherbini Elazazy Elshal
SFSalma Fathy
Salma Fathy
WAWalid Al-zordk
Walid Al-zordk
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
ASAmal Sakrana
Amal Sakrana
Background/Objectives: Fabrication of ceramic restorations with higher performance, biocompatibility, and mechanical durability, as well as excellent optical properties, is challenging. Therefore, this study was designed to investigate the mechanical properties and surface roughness of different glass ceramics manufactured with CAD/CAM and pressed techniques before and after exposure to simulated gastric acidic challenge. Methods: Lithium disilicate-based (LDS) ceramic, advanced lithium disilicate (ALDS), and zirconia-reinforced lithium silicate (ZLSC), were manufactured with two techniques. Disc-shaped (N = 336) specimens were used to test the biaxial flexural strength (BFS), while surface microhardness and surface roughness were evaluated before and after exposure to hydrochloric acid (34–37% concentration and 1.2 pH for 24 h). The results were statistically evaluated using two- and one-way ANOVA, Tukey’s post-hoc and Student’s t-test. Results: Both CAD and pressed types of LDS ceramic IPS e.max, showed significantly highest BFS and microhardness before and after acidic challenge (p = 0.01 and <0.01, respectively). ALDS and ZLSC showed significantly lower roughness before acidic aging, while all groups showed no significant difference after aging. Conclusion: Pressed groups showed better mechanical performance than CAD groups. LSD (IPS e.max types) continuously showed a better mechanical performance than modified LDS. ALDS and ZLSC showed the best performance in terms of surface smoothness, but after acidic exposure, no significant difference was observed compared to the other groups.