Krunoslav Hajdek

Prof. Dr. Krunoslav Hajdek

University North
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Dean ValdecDean Valdec
Dean Valdec
KHKrunoslav Hajdek
Krunoslav Hajdek
Igor MajnarićIgor Majnarić
Igor Majnarić
DČDarijo Čerepinko
Darijo Čerepinko
This study characterizes and compares the parameters of the quality reproduction of fine elements in flexography on coated and uncoated paper as well as on OPP film (oriented polypropylene). A monochrome test form was created and printed using cyan UV ink. The analysis of results confirms the importance of interaction between the printing substrate and ink; it also indicates identical line and text deformations on the print. Quality reproduction on coated paper is higher in relation to OPP film for all the research parameters. The ink penetrates significantly more and with more irregularity into the pores and throats of the uncoated paper, which results in less homogeneous elements, and in such way that it loses its original shape. In coated paper and OPP film, the ink spreads more on the substrate area which gives it a significantly more homogeneous shape. However, due to the surface spread of the ink, the biggest changes in the size of fine elements are noticeable in the OPP film. The scientific contribution of this paper is based on the comparison of print quality parameters of fine elements, which can contribute to the optimization of the production process and quality of the final graphical product.

4 March 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Nikola SakačNikola Sakač
Nikola Sakač
DMDean Marković
Dean Marković
BSBojan Sarkanj
Bojan Sarkanj
DMDubravka Madunić-Čačić
Dubravka Madunić-Čačić
KHKrunoslav Hajdek
Krunoslav Hajdek
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
A novel, simple, low-cost, and user-friendly potentiometric surfactant sensor based on the new 1,3-dihexadecyl−1H-benzo[d]imidazol−3-ium-tetraphenylborate (DHBI–TPB) ion-pair for the detection of cationic surfactants in personal care products and disinfectants is presented here. The new cationic surfactant DHBI-Br was successfully synthesized and characterized by nuclear magnetic resonance (NMR), Fourier transform infrared (FTIR) spectrometry, liquid chromatography–mass spectrometry (LC–MS) and elemental analysis and was further employed for DHBI–TPB ion-pair preparation. The sensor gave excellent response characteristics for CTAB, CPC and Hyamine with a Nernstian slope (57.1 to 59.1 mV/decade) whereas the lowest limit of detection (LOD) value was measured for CTAB (0.3 × 10−6 M). The sensor exhibited a fast dynamic response to dodecyl sulfate (DDS) and TPB. High sensor performances stayed intact regardless of the employment of inorganic and organic cations and in a broad pH range (2−11). Titration of cationic and etoxylated (EO)-nonionic surfactant (NSs) (in Ba2+) mixtures with TPB revealed the first inflexion point for a cationic surfactant and the second for an EO-nonionic surfactant. The increased concentration of EO-nonionic surfactants and the number of EO groups had a negative influence on titration curves and signal change. The sensor was successfully applied for the quantification of technical-grade cationic surfactants and in 12 personal care products and disinfectants. The results showed good agreement with the measurements obtained by a commercial surfactant sensor and by a two-phase titration. A good recovery for the standard addition method (98–102%) was observed.

20 January 2021 in Metals
Verified
Journal Article
Open access
PDF file
Sunčana Smokvina HanzaSunčana Smokvina Hanza
Sunčana Smokvina Hanza
BSBožo Smoljan
Božo Smoljan
Lovro ŠticLovro Štic
Lovro Štic
KHKrunoslav Hajdek
Krunoslav Hajdek
An increase in technical requirements related to the prediction of mechanical properties of steel engineering components requires a deep understanding of relations which exist between microstructure, chemical composition and mechanical properties. This paper is dedicated to the research of the relation between steel hardness with the microstructure, chemical composition and temperature of isothermal decomposition of austenite. When setting the equations for predicting the hardness of microstructure constituents, it was assumed that: (1) The pearlite hardness depends on the carbon content in a steel and on the undercooling below the critical temperature, (2) the martensite hardness depends primarily on its carbon content, (3) the hardness of bainite can be between that of untempered martensite and pearlite in the same steel. The equations for estimation of microstructure constituents’ hardness after the isothermal decomposition of austenite have been proposed. By the comparison of predicted hardness using a mathematical model with experimental results, it can be concluded that hardness of considered low-alloy steels could be successfully predicted by the proposed model.

14 June 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Nikola SakačNikola Sakač
Nikola Sakač
DMDubravka Madunić-Čačić
Dubravka Madunić-Čačić
DMDean Marković
Dean Marković
LHLucija Hok
Lucija Hok
Robert VianelloRobert Vianello
Robert Vianello
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C–H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10−7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10−7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2–10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring.

11 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Dean ValdecDean Valdec
Dean Valdec
KHKrunoslav Hajdek
Krunoslav Hajdek
LVLucia Vragović
Lucia Vragović
RGRobert Geček
Robert Geček
This paper researches the issues related to the print quality in flexography, especially the influence of the print run and inadequate printing settings on dot deformation. Dot deformation can lead to inconsistencies in print quality, such as a loss of highlight tones or an unpredictable increase in tonal value. This research was conducted on two concrete examples of flexible packaging printed on transparent films. All significant parameters of dot deformation were evaluated, including dot coverage, dot sharpness and the uniformity of the ink density. The increase in the coverage values in the midtones was linear throughout the entire print run, while in the light tones, it was more logarithmic. The overall percentage deviations from the reference value were 6.3% in the midtones and 52.6% in the light area. The increase in dot coverage was due to the wear of the polymer plate, which caused the side shoulders of the dot to become a part of the printing surface. An analysis of the ink density showed a much more homogeneous shape of the dot at the beginning of the print run. The correct ratio of the anilox roller line screen to the line ruling of the printing plate is important in order to ensure a minimum dot size in print.

26 September 2022 in Tehnički glasnik
Verified
Journal Article
Closed access
PDF file
Ana MetikošAna Metikoš
Ana Metikoš
MTMario Tomiša
Mario Tomiša
MČMarko Čačić
Marko Čačić
KHKrunoslav Hajdek
Krunoslav Hajdek
Design thinking is an innovative way of thinking and solving problems in which the focus is on the user. This paper provides an overview of current research on the topic to gain insight into current practices and create a basis for further developmen...