A novel inertial piezoelectric actuator is proposed in this study to address the large vibration problem in piezoelectric actuators with a typical cantilever structure. Piezoelectric vibrators with a two fixed-end beam structure were designed as driving elements to improve the precision and stability of the proposed actuator. Simulation and experiments were performed to evaluate the vibration model of the vibrators. A series of experiments was conducted to evaluate the performance of the presented actuator with regard to its linearity, repeatability, and output stepping. Angular resolution can reach 0.453 μ rad at 36 V, 40 Hz, and 600 g load. Under the conditions of 40 V, 40 Hz, and 400 g load, repeatability reaches 0.0024 mrad with a maximum deviation of 0.007 mrad. Experimental results show that the designed actuator can achieve high precision and high stability under load conditions. This novel actuator has a reference value and significance in practical applications that require microdisplacement.
A linear inertial piezoelectric actuator using a single bimorph vibrator clamped by asymmetrical fixed beam structure is proposed in this paper to achieve extremely simple structure and high stability. It adopted one vibrator to produce the inertial impact force, which is beneficial to simplify the overall architecture. A dynamic model, based on the stiffness-damping vibration model and LuGre friction model, is established to predict the motion of the actuator by Matlab/Simulink. An experimental system is built to test its performance. Experimental results indicate that the stable minimum displacement is 1.9 μ m and the maximum repeat error rate reaches 1.1% under a square wave signal of 15 V, 2 Hz with no-load. When the load is 420 g, the minimum displacement is 0.6 μ m under 100 V and 2 Hz. Compared with similar actuators, the proposed actuator achieves much higher stable linear motion with a larger stroke and without drawback.
10 June 2019 in Journal of Intelligent Material Systems and Structures
This article proposes an inertial piezoelectric actuator with hybrid design of asymmetrically clamping structures and a bias unit for the achievement of large angular velocity and high resolution. To investigate the influence of asymmetrical clamp and bias unit on the driving performance, two types of actuators were fabricated and tested. Combined effects from asymmetrical clamp and bias unit contribute to type A, while their subtractive effect is applied to type B. Using a scanning laser vibrometer, experiments were conducted to analyze the characteristics of the angular displacement and corresponding velocity. It is indicated that the measured first-order natural frequencies for above two types are 13.828 and 14.141 Hz, which agrees well with the simulation results of 16.666 and 17.379 Hz, respectively. Besides, compared with the actuators with simple asymmetrical clamping structure or bias unit, this hybrid actuator can obtain an angular velocity 6.87 rad/s at 80 V and 16 Hz and a resolution of 2.80 μrad under a square signal of 20 V and 1 Hz and an offset distance of −22 mm. As a result, the proposed actuators can achieve large angular velocity and high resolution, which is potentially applicable to quick positioning with high accuracy.
A quantitative and rapid burn injury detection method has been proposed based on the electrical impedance spectroscopy (EIS) of blood with a seven-parameter equivalent circuit. The degree of burn injury is estimated from the electrical impedance characteristics of blood with different volume proportions of red blood cells (RBCs) and heated red blood cells (HRBCs). A quantitative relationship between the volume portion HHCT of HRBCs and the electrical impedance characteristics of blood has been demonstrated. A seven -parameter equivalent circuit is employed to quantify the relationship from the perspective of electricity. Additionally, the traditional Hanai equation has been modified to verify the experimental results. Results show that the imaginary part of impedance ZImt under the characteristic frequency (fc) has a linear relationship with HHCT which could be described by ZImt = −2.56HHCT − 2.01 with a correlation coefficient of 0.96. Moreover, the relationship between the plasma resistance Rp and HHCT is obtained as Rp = −7.2HHCT + 3.91 with a correlation coefficient of 0.96 from the seven -parameter equivalent circuit. This study shows the feasibility of EIS in the quantitative detection of burn injury by the quantitative parameters ZImt and Rp, which might be meaningful for the follow-up clinical treatment for burn injury.
Enhancing the detection limit in protein analysis is essential for a wide range of biomedical applications. In typical fluorescent protein assays, this limit is constrained by the detection capacity of the photon detector. Here, we develop an approach that significantly enhances the protein detection threshold by using microscale isoelectric focusing implemented directly at the detection site on a protein sensor chip. We demonstrate that by electrically generating a localized pH environment within a radius of ∼60 μm, protein molecules can be concentrated within this range and be detected at levels over four times lower than those achieved by measurements without on-chip isoelectric focusing. We find that this detection-limit enhancement results from a dual effect: the concentrating of the protein molecules and a reduction in the diffusion-induced fluctuation. Our approach offers a simple, yet highly effective ultra-low-power all-electronic solution for substantially improving protein analysis detection limits for diverse applications, including healthcare, clinical diagnostics, and therapeutics.