22 December 2022 in Small
19 March 2021 in Nature Communications
All-electronic interrogation of biofluid flow velocity by electrical nanosensors incorporated in ultra-low-power or self-sustained systems offers the promise of enabling multifarious emerging research and applications. However, existing nano-based electrical flow sensing technologies remain lacking in precision and stability and are typically only applicable to simple aqueous solutions or liquid/gas dual-phase mixtures, making them unsuitable for monitoring low-flow (~micrometer/second) yet important characteristics of continuous biofluids (such as hemorheological behaviors in microcirculation). Here, we show that monolayer-graphene single microelectrodes harvesting charge from continuous aqueous flow provide an effective flow sensing strategy that delivers key performance metrics orders of magnitude higher than other electrical approaches. In particular, over six-months stability and sub-micrometer/second resolution in real-time quantification of whole-blood flows with multiscale amplitude-temporal characteristics are obtained in a microfluidic chip.
4 March 2024 in Applied Physics Letters
Enhancing the detection limit in protein analysis is essential for a wide range of biomedical applications. In typical fluorescent protein assays, this limit is constrained by the detection capacity of the photon detector. Here, we develop an approach that significantly enhances the protein detection threshold by using microscale isoelectric focusing implemented directly at the detection site on a protein sensor chip. We demonstrate that by electrically generating a localized pH environment within a radius of ∼60 μm, protein molecules can be concentrated within this range and be detected at levels over four times lower than those achieved by measurements without on-chip isoelectric focusing. We find that this detection-limit enhancement results from a dual effect: the concentrating of the protein molecules and a reduction in the diffusion-induced fluctuation. Our approach offers a simple, yet highly effective ultra-low-power all-electronic solution for substantially improving protein analysis detection limits for diverse applications, including healthcare, clinical diagnostics, and therapeutics.
7 August 2023 in Proceedings of the National Academy of Sciences
Electronic detection of DNA oligomers offers the promise of rapid, miniaturized DNA analysis across various biotechnological applications. However, known all-electrical methods, which solely rely on measuring electrical signals in transducers during probe–target DNA hybridization, are prone to nonspecific electrostatic and electrochemical interactions, subsequently limiting their specificity and detection limit. Here, we demonstrate a nanomechanoelectrical approach that delivers ultra-robust specificity and a 100-fold improvement in detection limit. We drive nanostructural DNA strands tethered to a graphene transistor to oscillate in an alternating electric field and show that the transistor-current spectra are characteristic and indicative of DNA hybridization. We find that the inherent difference in pliability between unpaired and paired DNA strands leads to the spectral characteristics with minimal influence from nonspecific electrostatic and electrochemical interactions, resulting in high selectivity and sensitivity. Our results highlight the potential of high-performance DNA analysis based on miniaturized all-electronic settings.
24 January 2022 in Applied Physics Letters
Precise sensing of microfluidic flow is essential to advancing lab-on-a-chip development and the downstream medical applications. Contactless microfluidic flow interrogation is noninvasive, nonperturbative, and fouling-free. However, known real non-contact flow sensing technologies are limited to quantifying bulk fluids. Here, we develop an electrical approach to contactless quantification of aqueous microfluidic flow. We found that the electric potential generated by the ubiquitous contact electrification of a microfluidic flow with fluidic channel walls is interrogatable by using a probe electrode at a distance over centimeters from the microfluidic flow, and the measured voltage response demonstrates linear relationship to the microfluidic flow rate with a resolution of sub-microliter per minute (in a 1-Hz bandwidth), providing an ideal, high-precision contactless flow transduction pathway. In addition to this primary finding, by using a monolayer-graphene coated probe electrode, in comparison with a typical bare probe electrode, an overall enhancement in flow-sensory resolution of 36.4% is attained.
14 October 2024 in Applied Physics Letters
Real-time, all-electronic control of non-Newtonian fluid flow through a microscale channel is crucial for various applications in manufacturing and healthcare. However, existing methods lack the sensitivity required for accurate measurement and the real-time responsiveness necessary for effective adjustment. Here, we demonstrate an all-electronic system that enables closed-loop, real-time, high-sensitivity control of various waveforms of non-Newtonian fluid flow (0.76 μl min−1) through a micro-sized outlet. Our approach combines a contactless, cuff-like flow sensor with a neural-network control program. This system offers a simple, miniaturized, versatile, yet high-performance solution for non-Newtonian fluid flow control, easily integrated into existing setups.