Alexander Robertson

Dr. Alexander Robertson

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2020 in Cancers
Verified
Journal Article
Open access
PDF file
Wojciech M. MarliczWojciech M. Marlicz
Wojciech M. Marlicz
XRXuyang Ren
Xuyang Ren
ARAlexander Robertson
Alexander Robertson
Karolina Skonieczna-ŻydeckaKarolina Skonieczna-Żydecka
Karolina Skonieczna-Żydecka
IŁIgor Łoniewski
Igor Łoniewski
GCGastone Ciuti
Gastone Ciuti
Upper gastrointestinal (UGI) tract pathology is common worldwide. With recent advancements in robotics, innovative diagnostic and treatment devices have been developed and several translational attempts made. This review paper aims to provide a highly pictorial critical review of robotic gastroscopes, so that clinicians and researchers can obtain a swift and comprehensive overview of key technologies and challenges. Therefore, the paper presents robotic gastroscopes, either commercial or at a progressed technology readiness level. Among them, we show tethered and wireless gastroscopes, as well as devices aimed for UGI surgery. The technological features of these instruments, as well as their clinical adoption and performance, are described and compared. Although the existing endoscopic devices have thus far provided substantial improvements in the effectiveness of diagnosis and treatment, there are certain aspects that represent unwavering predicaments of the current gastroenterology practice. A detailed list includes difficulties and risks, such as transmission of communicable diseases (e.g., COVID-19) due to the doctor–patient proximity, unchanged learning curves, variable detection rates, procedure-related adverse events, endoscopists’ and nurses’ burnouts, limited human and/or material resources, and patients’ preferences to choose non-invasive options that further interfere with the successful implementation and adoption of routine screening. The combination of robotics and artificial intelligence, as well as remote telehealth endoscopy services, are also discussed, as viable solutions to improve existing platforms for diagnosis and treatment are emerging.

10 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PVPablo Cortegoso Valdivia
Pablo Cortegoso Valdivia
ARAlexander Robertson
Alexander Robertson
NBNanne De Boer
Nanne De Boer
Wojciech M. MarliczWojciech M. Marlicz
Wojciech M. Marlicz
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
The introduction of capsule endoscopy two decades ago marked the beginning of the “small bowel revolution”. Since then, the rapid evolution of microtechnology has allowed the development of drug delivery systems (DDS) designed to address some of the needs that are not met by standard drug delivery. To overcome the complex anatomy and physiology of the gastrointestinal (GI) tract, several DDS have been developed, including many prototypes being designed, built and eventually produced with ingenious drug-release mechanisms and anchoring systems allowing targeted therapy. This review highlights the currently available systems for drug delivery in the GI tract and discusses the needs, limitations, and future considerations of these technologies.

16 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SGSarah-Louise Gillespie
Sarah-Louise Gillespie
NMNorma C. McAvoy
Norma C. McAvoy
DYDiana E. Yung
Diana E. Yung
ARAlexander Robertson
Alexander Robertson
John PlevrisJohn Plevris
John Plevris
PHPeter C. Hayes
Peter C. Hayes
Variceal haemorrhage is a severe complication of liver disease with high mortality. Human recombinant thrombin has gained popularity in the management of variceal haemorrhage. We report on the use of thrombin for gastric and ectopic varices at a regional tertiary care centre. This was a retrospective observational study. Patients with portal hypertension who received endoscopic injection of recombinant thrombin were identified and data collected on haemostasis and rebleeding rates, complications and mortality. Patients were grouped by indication for thrombin injection: gastric/oesophageal/ectopic varices and endoscopic band ligation (EBL)-induced ulceration. 155 patients (96M/59F, mean age 58.3 years) received endoscopic thrombin injection. Mean volume of thrombin injected at index endoscopy was 9.5 ml/2375IU. Initial haemostasis was achieved in 144 patients (92.9%). Rebleeding occurred in a total of 53 patients (36.8%) divided as follows: early rebleeding ( 30 days)—11 patients (7.6%). There was statistically significant difference in rate of initial haemostasis between Child-Pugh A/B patients vs Child-Pugh C (p = 0.046). There was no significant difference in rebleeding rates between different indication groups (p = 0.78), by presence of cirrhosis or by Child-Pugh Score. All-cause mortality at 6 weeks was 18.7%; 1-year mortality 37.4% (median follow-up 48 months). There was no significant difference in mortality between groups (p = 0.37). No significant adverse events or complications were reported. Thrombin is effective and safe for gastric varices and other portal-hypertension-related bleeding including oesophageal varices, ulcers secondary to EBL and ectopic varices.

1 January 2017 in World Journal of Gastrointestinal Endoscopy
Verified
Journal Article
Open access
ARAlexander Robertson
Alexander Robertson
NKNicholas Alexander Kennedy
Nicholas Alexander Kennedy
JRJames A Robertson
James A Robertson
NCNicholas I Church
Nicholas I Church
CNColin L Noble
Colin L Noble
To compare colonoscopy quality with nitrous oxide gas (Entonox®) against intravenous conscious sedation using midazolam plus opioid. A retrospective analysis was performed on a prospectively held database of 18608 colonoscopies carried out in Lothian health board hospitals between July 2013 and January 2016. The quality of colonoscopies performed with Entonox was compared to intravenous conscious sedation (abbreviated in this article as IVM). Furthermore, the quality of colonoscopies performed with an unmedicated group was compared to IVM. The study used the following key markers of colonoscopy quality: (1) patient comfort scores; (2) caecal intubation rates (CIRs); and (3) polyp detection rates (PDRs). We used binary logistic regression to model the data. There was no difference in the rate of moderate-to-extreme discomfort between the Entonox and IVM groups (17.9% vs 18.8%; OR = 1.06, 95%CI: 0.95-1.18, P = 0.27). Patients in the unmedicated group were less likely to experience moderate-to-extreme discomfort than those in the IVM group (11.4% vs 18.8%; OR = 0.71, 95%CI: 0.60-0.83, P < 0.001). There was no difference in caecal intubation between the Entonox and IVM groups (94.4% vs 93.7%; OR = 1.08, 95%CI: 0.92-1.28, P = 0.34). There was no difference in caecal intubation between the unmedicated and IVM groups (94.2% vs 93.7%; OR = 0.98, 95%CI: 0.79-1.22, P = 0.87). Polyp detection in the Entonox group was not different from IVM group (35.0% vs 33.1%; OR = 1.01, 95%CI: 0.93-1.10, P = 0.79). Polyp detection in the unmedicated group was not significantly different from the IVM group (37.4% vs 33.1%; OR = 0.97, 95%CI: 0.87-1.08, P = 0.60). The use of Entonox was not associated with lower colonoscopy quality when compared to intravenous conscious sedation using midazolam plus opioid.

24 April 2019 in Scandinavian Journal of Gastroenterology
Verified
Journal Article
Closed access
ARAlexander Robertson
Alexander Robertson
DYD. E. Yung
D. E. Yung
SDS. Douglas
S. Douglas
JPJ. N. Plevris
J. N. Plevris
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
Objectives: This study aims to review the utility of repeat capsule endoscopy (CE) with on-going concern of small bowel (SB) bleeding following initial SB investigation with CE. Materials and methods: A specifically designed database of CE examinations performed over 13 years, with hospital records, was retrospectively interrogated for patients undergoing multiple CEs to investigate iron deficiency anaemia (IDA) or suspected SB bleeding. Results: 1335/2276 (58.7%) of CEs were performed to investigate IDA or SB bleeding; 92 were repeat CEs carried out for ongoing clinical concern. The median time interval between initial and repeat CE procedures was 466.5 (range 1–3066) days. Twenty-four patients had initially normal CE; on repeat examination, abnormalities were detected in 11/24 (45.8%). 3/21 (14.2%) of patients with angioectasia on first CE had alternative causes for IDA or GI bleeding detected on repeat CE. Six patients with active bleeding, without an identifiable source on initial CE, undergoing repeat CE had a cause isolated in 5/6 (83.3%). Changing CE device did not affect diagnostic yield (DY) compared to repeat CE using the same device (27.5% to 26.8%). Conclusions: It is known that CE can miss clinically relevant and serious lesions. Our results suggest that patients with an initially negative or inconclusive CE frequently have a cause of SB bleeding detected on repeat CE. The DY of repeat CE is highest in those with bleeding on their initial CE (83.3%) and lower in those with initially normal examinations (45.8%) or when an alternative cause, such as angioectasia is seen (14.2%).

13 July 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Luca ElliLuca Elli
Luca Elli
BMBeatrice Marinoni
Beatrice Marinoni
RSReena Sidhu
Reena Sidhu
CBChristian Bojarski
Christian Bojarski
FBFederica Branchi
Federica Branchi
RARimondi Alessandro
Rimondi Alessandro
(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.