Gastone Ciuti

Dr. Gastone Ciuti


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TCTamás Czimmerman
Tamás Czimmerman
GCGastone Ciuti
Gastone Ciuti
Mario MilazzoMario Milazzo
Mario Milazzo
MCMarcello Chiurazzi
Marcello Chiurazzi
SRStefano Roccella
Stefano Roccella
PDPaolo Dario
Paolo Dario
This paper reviews automated visual-based defect detection approaches applicable to various materials, such as metals, ceramics and textiles. In the first part of the paper, we present a general taxonomy of the different defects that fall in two classes: visible (e.g., scratches, shape error, etc.) and palpable (e.g., crack, bump, etc.) defects. Then, we describe artificial visual processing techniques that are aimed at understanding of the captured scenery in a mathematical/logical way. We continue with a survey of textural defect detection based on statistical, structural and other approaches. Finally, we report the state of the art for approaching the detection and classification of defects through supervised and non-supervised classifiers and deep learning.

10 October 2011 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
GCGastone Ciuti
Gastone Ciuti
AMArianna Menciassi
Arianna Menciassi
PDPaolo Dario
Paolo Dario
Wireless capsule endoscopy (WCE) can be considered an example of disruptive technology since it represents an appealing alternative to traditional diagnostic techniques. This technology enables inspection of the digestive system without discomfort or need for sedation, thus preventing the risks of conventional endoscopy, and has the potential of encouraging patients to undergo gastrointestinal (GI) tract examinations. However, currently available clinical products are passive devices whose locomotion is driven by natural peristalsis, with the drawback of failing to capture the images of important GI tract regions, since the doctor is unable to control the capsule's motion and orientation. To address these limitations, many research groups are working to develop active locomotion devices that allow capsule endoscopy to be performed in a totally controlled manner. This would enable the doctor to steer the capsule towards interesting pathological areas and to accomplish medical tasks. This review presents a research update on WCE and describes the state of the art of the basic modules of current swallowable devices, together with a perspective on WCE potential for screening, diagnostic, and therapeutic endoscopic procedures.

26 October 2009 in Robotica
Verified
Journal Article
Closed access
PDF file
GCGastone Ciuti
Gastone Ciuti
PVPietro Valdastri
Pietro Valdastri
AMArianna Menciassi
Arianna Menciassi
PDPaolo Dario
Paolo Dario
SUMMARY: This paper describes a novel approach to capsular endoscopy that takes advantage of active magnetic locomotion in the gastrointestinal tract guided by an anthropomorphic robotic arm. Simulations were performed to select the design parameters allowing an effective and reliable magnetic link between the robot end-effector (endowed with a permanent magnet) and the capsular device (endowed with small permanent magnets). In order to actively monitor the robotic endoluminal system and to efficiently perform diagnostic and surgical medical procedures, a feedback control based on inertial sensing was also implemented. The proposed platform demonstrated to be a reliable solution to move and steer a capsular device in a slightly insufflated gastrointestinal lumen.

2 September 2019 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
ASAngela Sorriento
Angela Sorriento
MPMaria Bianca Porfido
Maria Bianca Porfido
Stefano MazzoleniStefano Mazzoleni
Stefano Mazzoleni
GCGiuseppe Calvosa
Giuseppe Calvosa
MTMiria Tenucci
Miria Tenucci
PDPaolo Dario
Paolo Dario
Optical and electromagnetic tracking systems represent the two main technologies integrated into commercially-available surgical navigators for computer-assisted image-guided surgery so far. Optical Tracking Systems (OTSs) work within the optical spectrum to track the position and orientation, i.e., pose of target surgical instruments. OTSs are characterized by high accuracy and robustness to environmental conditions. The main limitation of OTSs is the need of a direct line-of-sight between the optical markers and the camera sensor, rigidly fixed into the operating theatre. Electromagnetic Tracking Systems (EMTSs) use electromagnetic field generator to detect the pose of electromagnetic sensors. EMTSs do not require such a direct line-of-sight, however the presence of metal or ferromagnetic sources in the operating workspace can significantly affect the measurement accuracy. The aim of the proposed review is to provide a complete and detailed overview of optical and electromagnetic tracking systems, including working principles, source of error and validation protocols. Moreover, commercial and research-oriented solutions, as well as clinical applications, are described for both technologies. Finally, a critical comparative analysis of the state of the art which highlights the potentialities and the limitations of each tracking system for a medical use is provided.

28 April 2017 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
GGGiada Gerboni
Giada Gerboni
ADAlessandro Diodato
Alessandro Diodato
GCGastone Ciuti
Gastone Ciuti
MCMatteo Cianchetti
Matteo Cianchetti
AMArianna Menciassi
Arianna Menciassi
Soft robotics is an emerging field that takes advantage of compliant materials and makes use of nonstandard actuators. Flexible fluid actuators (FFAs) use fluid pressure to produce high deformation of elastomeric-based structures. However, closed-loop control of such actuators is still very challenging due to the lack of robust, reliable, and inexpensive sensors that can be integrated onto highly deformable actuator structures, involving very low cost materials and manufacturing. This paper presents a systematic approach to implement the feedback control of FFA-based soft robotic bending modules by using commercial flex bend sensors. A flex bend sensor detects the module curvature in one direction, and its response is processed by an on board microcontroller and sent to the central control system. Such sensor integration enables the closed-loop control of modular robotic architectures, often used in soft robotics. Once integrated with the soft module, the sensor response was calibrated by the use of a ground truth electro-magnetic tracking system in order to characterize its behavior when combined with the relative FFA. A feedback control using a low-pass filter and a proportional-integral controller was designed and used to evaluate the dynamic response and the position accuracy of the integrated module. With such closed-loop control, the module tip is positioned with less than 1 mm accuracy, which can be considered a relevant result in the soft robotics field.

2 May 2016 in Journal of Micro and Bio Robotics
Verified
Journal Article
Open access
PDF file
GCGastone Ciuti
Gastone Ciuti
RCRenato Calio'
Renato Calio'
DCDomenico Camboni
Domenico Camboni
Luca NeriLuca Neri
Luca Neri
FBF. Bianchi
F. Bianchi
PDP. Dario
P. Dario
Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.