Background: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. Methods: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. Results: In propensity–matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46–1.91]; P <0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63–2.22]; P <0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07–1.66]; P =0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06–1.29]; P =0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. Conclusion: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. Clinical Trial Registration: https://www.clinicaltrials.gov . Unique identifier: NCT01777828.
Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.)
Rationale:: Percutaneous aortic valve procedures are a major breakthrough in the management of patients with aortic stenosis. Residual gradient and residual aortic regurgitation are major predictors of midterm and long-term outcome after percutaneous aortic valve procedures. We hypothesized that (1) induction/recovery of high molecular weight (HMW) multimers of von Willebrand factor defect could be instantaneous after acute changes in blood flow, (2) a bedside point-of-care assay (platelet function analyzer-closure time adenine DI-phosphate [PFA-CADP]), reflecting HMW multimers changes, could be used to monitor in real-time percutaneous aortic valve procedures. Objective:: To investigate the time course of HMW multimers changes in models and patients with instantaneous induction/reversal of pathological high shear and its related bedside assessment. Methods and Results:: We investigated the time course of the induction/recovery of HMW multimers defects under instantaneous changes in shear stress in an aortic stenosis rabbit model and in patients undergoing implantation of a continuous flow left ventricular assist device. We further investigated the recovery of HMW multimers and monitored these changes with PFA-CADP in aortic stenosis patients undergoing transcatheter aortic valve implantation or balloon valvuloplasty. Experiments in the aortic stenosis rabbit model and in left ventricular assist device patients demonstrated that induction/recovery of HMW multimers occurs within 5 minutes. Transcatheter aortic valve implantation patients experienced an acute decrease in shear stress and a recovery of HMW multimers within minutes of implantation which was sustained overtime. In patients with residual high shear or with residual aortic regurgitation, no recovery of HMW multimers was observed. PFA-CADP profiles mimicked HMW multimers recovery both in transcatheter aortic valve implantation patients without aortic regurgitation (correction) and transcatheter aortic valve implantation patients with aortic regurgitation or balloon valvuloplasty patients (no correction). Conclusions:: These results demonstrate that variations in von Willebrand factor multimeric pattern are highly dynamic, occurring within minutes after changes in blood flow. It also demonstrates that PFA-CADP can evaluate in real time the results of transcatheter aortic valve procedures.
The aim of the study was to assess the outcomes of balloon aortic valvuloplasty (BAV) as a rescue therapy in patients with cardiogenic shock (CS) related to severe aortic stenosis (AS). Forty-four consecutive patients, n=31 with hypotensive CS (HCS) and n=13 with non-hypotensive CS (NHCS) due to acutely decompensated severe AS, from two centres were treated with urgent BAV. The composite primary endpoint was mortality or recurrent CS at one-year follow-up. These patients (77.3±8.1 years old; 75% male) had a mean EuroSCORE II of 41.6±13.7%. One-month mortality was 47%. Twelve patients (27%) had either a staged TAVR (n=10) or surgical aortic valve replacement (SAVR) (n=2) with a median delay of 79 days after BAV: n=6 (19%) in the HCS subgroup and n=6 (46%) in the NHCS population (p=0.06). At one year, the rate of composite all-cause death or recurrent CS was 75% and significantly higher in the HCS subgroup (83% vs. 53%; p=0.03). Overall one-year mortality was 70% (n=31) with a trend for a better prognosis in NHCS patients (54% vs. 77%; p=0.09). Univariate predictive factors of the primary endpoint included preoperative dose of dobutamine >5 microg/kg/min (100% vs. 57%; p=0.001) and delayed BAV >48 hrs (90% vs. 59%; p=0.01). Despite the initial success of urgent BAV, morbidity and mortality of CS related to severe AS remain high and directly related to the time of the valvuloplasty. Performing BAV before or within 48 hours of starting inotropic agents appears to be key to survival.