Regenerative therapies based on tissue engineering are becoming the most promising alternative for the treatment of osteoarthritis and rheumatoid arthritis. However, regeneration of full-thickness articular osteochondral defects that reproduces the complexity of native cartilage and osteochondral interface still remains challenging. Hence, in this work, we present the fabrication, physic-chemical characterization, and in vitro and in vivo evaluation of biomimetic hierarchical scaffolds that mimic both the spatial organization and composition of cartilage and the osteochondral interface. The scaffold is composed of a composite porous support obtained by cryopolymerization of poly(ethylene glycol) dimethacrylate (PEGDMA) in the presence of biodegradable poly(D,L-lactide-co-glycolide) (PLGA), bioactive tricalcium phosphate β-TCP and the bone promoting strontium folate (SrFO), with a gradient biomimetic photo-polymerized methacrylated hyaluronic acid (HAMA) based hydrogel containing the bioactive zinc folic acid derivative (ZnFO). Microscopical analysis of hierarchical scaffolds showed an open interconnected porous open microstructure and the in vitro behaviour results indicated high swelling capacity with a sustained degradation rate. In vitro release studies during 3 weeks indicated the sustained leaching of bioactive compounds, i.e., Sr2+, Zn2+ and folic acid, within a biologically active range without negative effects on human osteoblast cells (hOBs) and human articular cartilage cells (hACs) cultures. In vitro co-cultures of hOBs and hACs revealed guided cell colonization and proliferation according to the matrix microstructure and composition. In vivo rabbit-condyle experiments in a critical-sized defect model showed the ability of the biomimetic scaffold to promote the regeneration of cartilage-like tissue over the scaffold and neoformation of osteochondral tissue.
The first-line treatment of osteoarthritis is based on anti-inflammatory drugs, the most currently used being nonsteroidal anti-inflammatory drugs, selective cyclooxygenase 2 (COX-2) inhibitors and corticoids. Most of them present cytotoxicity and low bioavailability in physiological conditions, making necessary the administration of high drug concentrations causing several side effects. The goal of this work was to encapsulate three hydrophobic anti-inflammatory drugs of different natures (celecoxib, tenoxicam and dexamethasone) into core-shell terpolymer nanoparticles with potential applications in osteoarthritis. Nanoparticles presented hydrodynamic diameters between 110 and 130 nm and almost neutral surface charges (between −1 and −5 mV). Encapsulation efficiencies were highly dependent on the loaded drug and its water solubility, having higher values for celecoxib (39–72%) followed by tenoxicam (20–24%) and dexamethasone (14–26%). Nanoencapsulation reduced celecoxib and dexamethasone cytotoxicity in human articular chondrocytes and murine RAW264.7 macrophages. Moreover, the three loaded systems did not show cytotoxic effects in a wide range of concentrations. Celecoxib and dexamethasone-loaded nanoparticles reduced the release of different inflammatory mediators (NO, TNF-α, IL-1β, IL-6, PGE2 and IL-10) by lipopolysaccharide (LPS)-stimulated RAW264.7. Tenoxicam-loaded nanoparticles reduced NO and PGE2 production, although an overexpression of IL-1β, IL-6 and IL-10 was observed. Finally, all nanoparticles proved to be biocompatible in a subcutaneous injection model in rats. These findings suggest that these loaded nanoparticles could be suitable candidates for the treatment of inflammatory processes associated with osteoarthritis due to their demonstrated in vitro activity as regulators of inflammatory mediator production.
Statement of the problem: The gingival configuration around implant abutments is of paramount importance for preserving the underlying marginal bone, and hence for the long-term success of dental implants. Objective: The objective was to study, clinically and histologically, the effects of the change in the morphology of abutments connected to the endosseous implant, and of their surface treatment. In particular, the objective was to ascertain the effect of changing the shape of the transepithelial pillar and the treatment of its surface on the dimensions, quality and health of the components of the peri-implant biological space, such as the dimensions of the epithelial and connective tissues of the biological space, the concentration of inflammatory cells and the density of collagen fibers. Methods: A clinical trial of 10 patients with a totally edentulous maxilla, who had four implants (IPX4010_GALIMPLANT®, Sarria, Spain) inserted in the area of the first and second molars on both sides with computer-guided implant surgery, was conducted with the final purpose of assessing the quality of the peri-implant soft tissue attachment around the transepithelial abutments which were employed (aesthetic machined (RM), aesthetic anodized (RA), slim machined (SM) and slim anodized (SA)). At 8 weeks and following the collection of the samples (removal of the implant-abutment assembly with its surrounding hard and soft tissue) and their processing for subsequent histological and histomorphometric analysis in order to study the dimensions, quality and health of the peri-implant soft tissue area, the variables previously mentioned were determined according to the aims of the study. By using appropriate diameter trephine in order to obtain a useful fringe of soft tissue around the transepithelial pillars, ANOVA and chi-square tests were performed. Results: The SPSS statistical analysis ANOVA results revealed that the machined slim abutments have a better performance considering the variables analyzed with epithelial and connective attachment heights of 1.52 mm and 2.3 mm, respectively, and that connective density (density of collagen fibers) was high at 85.7% of the sample size affected by the design for the slim abutments and 92.9% of the high-density sample size affected by the surface treatment for the machined surface. Conclusions: All variables studied, despite the small sample size, showed the superiority of the slim machined abutment among the four groups.