Yasmina Guadilla

Dr. Yasmina Guadilla

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
GAGerardo Asensio
Gerardo Asensio
LBLorena Benito-Garzón
Lorena Benito-Garzón
RJROSA ANA Ramírez Jiménez
ROSA ANA Ramírez Jiménez
YGYasmina Guadilla
Yasmina Guadilla
JGJulian Gonzalez-Rubio
Julian Gonzalez-Rubio
Luis Rojo Del OlmoLuis Rojo Del Olmo
Luis Rojo Del Olmo
Regenerative therapies based on tissue engineering are becoming the most promising alternative for the treatment of osteoarthritis and rheumatoid arthritis. However, regeneration of full-thickness articular osteochondral defects that reproduces the complexity of native cartilage and osteochondral interface still remains challenging. Hence, in this work, we present the fabrication, physic-chemical characterization, and in vitro and in vivo evaluation of biomimetic hierarchical scaffolds that mimic both the spatial organization and composition of cartilage and the osteochondral interface. The scaffold is composed of a composite porous support obtained by cryopolymerization of poly(ethylene glycol) dimethacrylate (PEGDMA) in the presence of biodegradable poly(D,L-lactide-co-glycolide) (PLGA), bioactive tricalcium phosphate β-TCP and the bone promoting strontium folate (SrFO), with a gradient biomimetic photo-polymerized methacrylated hyaluronic acid (HAMA) based hydrogel containing the bioactive zinc folic acid derivative (ZnFO). Microscopical analysis of hierarchical scaffolds showed an open interconnected porous open microstructure and the in vitro behaviour results indicated high swelling capacity with a sustained degradation rate. In vitro release studies during 3 weeks indicated the sustained leaching of bioactive compounds, i.e., Sr2+, Zn2+ and folic acid, within a biologically active range without negative effects on human osteoblast cells (hOBs) and human articular cartilage cells (hACs) cultures. In vitro co-cultures of hOBs and hACs revealed guided cell colonization and proliferation according to the matrix microstructure and composition. In vivo rabbit-condyle experiments in a critical-sized defect model showed the ability of the biomimetic scaffold to promote the regeneration of cartilage-like tissue over the scaffold and neoformation of osteochondral tissue.

5 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Javier MonteroJavier Montero
Javier Montero
YGYasmina Guadilla
Yasmina Guadilla
Javier FloresJavier Flores
Javier Flores
BPBeatriz Pardal-Peláez
Beatriz Pardal-Peláez
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
IZIbrahim Dib Zaitun
Ibrahim Dib Zaitun
This study aims to assess the treatment outcomes (functional and subjective) of full-arch fixed hybrid rehabilitations made of PEEK (poly-ether-ether-ketone) with milled crowns of nano-filled composite (NFC) supported on four to six implants. In this randomized clinical trial, 34 edentate patients in the upper and/or the lower jaws were treated with the fixed hybrid dentures. In 16 patients (47.1% of the sample), the implants were loaded immediately (IL) by means of a provisional fixed rehabilitation made of PMMA (polymethylmethacrylate) screwed on Multi-Unit (MU) abutments connected after emplacement of the implant; however, in the counterparts (n = 18) these MU abutments were covered by healing caps and were left unloaded during two months (conventional loading protocol—CL), when all patients received a fixed hybrid PEEK-NFC rehabilitation on the upper and/or the lower jaw. Treatment outcomes were assessed 12 months after prostheses delivery. Functional outcomes were calculated according to masticatory performance, estimated by mixing ability tests of two colored chewing gums after ten chewing strokes, by the occlusal force/area recorded by pressure-sensitive sheets, and by electromyography of masseters and temporal muscles at maximum biteforce. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analog scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study showed that treatment with fixed PEEK-NFC hybrid prostheses significantly improved the masticatory performance, bite force, occlusal pattern, quality of life, and satisfaction, with the IL group being those with significantly higher occlusal bite forces and greater satisfaction in comparison with CL group. It should be concluded that PEEK-NFC hybrid prostheses can improve several patient-centered outcomes and that loading protocol significantly affects the patient’s self-rated satisfaction.

22 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
IZIbrahim Dib Zaitun
Ibrahim Dib Zaitun
YGYasmina Guadilla
Yasmina Guadilla
Javier FloresJavier Flores
Javier Flores
JZJuan Dib Zakkour
Juan Dib Zakkour
LBLorena Benito-Garzón
Lorena Benito-Garzón
Javier MonteroJavier Montero
Javier Montero
Statement of the problem: The gingival configuration around implant abutments is of paramount importance for preserving the underlying marginal bone, and hence for the long-term success of dental implants. Objective: The objective was to study, clinically and histologically, the effects of the change in the morphology of abutments connected to the endosseous implant, and of their surface treatment. In particular, the objective was to ascertain the effect of changing the shape of the transepithelial pillar and the treatment of its surface on the dimensions, quality and health of the components of the peri-implant biological space, such as the dimensions of the epithelial and connective tissues of the biological space, the concentration of inflammatory cells and the density of collagen fibers. Methods: A clinical trial of 10 patients with a totally edentulous maxilla, who had four implants (IPX4010_GALIMPLANT®, Sarria, Spain) inserted in the area of the first and second molars on both sides with computer-guided implant surgery, was conducted with the final purpose of assessing the quality of the peri-implant soft tissue attachment around the transepithelial abutments which were employed (aesthetic machined (RM), aesthetic anodized (RA), slim machined (SM) and slim anodized (SA)). At 8 weeks and following the collection of the samples (removal of the implant-abutment assembly with its surrounding hard and soft tissue) and their processing for subsequent histological and histomorphometric analysis in order to study the dimensions, quality and health of the peri-implant soft tissue area, the variables previously mentioned were determined according to the aims of the study. By using appropriate diameter trephine in order to obtain a useful fringe of soft tissue around the transepithelial pillars, ANOVA and chi-square tests were performed. Results: The SPSS statistical analysis ANOVA results revealed that the machined slim abutments have a better performance considering the variables analyzed with epithelial and connective attachment heights of 1.52 mm and 2.3 mm, respectively, and that connective density (density of collagen fibers) was high at 85.7% of the sample size affected by the design for the slim abutments and 92.9% of the high-density sample size affected by the surface treatment for the machined surface. Conclusions: All variables studied, despite the small sample size, showed the superiority of the slim machined abutment among the four groups.

23 July 2024 in Journal of Dentistry
Verified
Journal Article
Open access
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
YGYasmina Guadilla
Yasmina Guadilla
CGCristina Gómez-Polo
Cristina Gómez-Polo
Nansi López-ValverdeNansi López-Valverde
Nansi López-Valverde
Javier FloresJavier Flores
Javier Flores
Javier MonteroJavier Montero
Javier Montero
To evaluate the bone changes around equicrestal and subcrestal implants, analyzing the effect of abutment height [short abutments (SA < 2 mm) and long abutments (LA > 2 mm)] and the three components of the peri‑implant soft-tissue phenotype. Twenty-six patients received 71 implants that were placed according to supracrestal tissue height (STH) in an equicrestal (n = 17), shallow subcrestal ≈1 mm (n = 33), or deep subcrestal ≈2 mm (n = 21) position. After 3 months of healing, rehabilitation was completed using metal-ceramic crowns on multi-unit abutments of 1.5 mm, 2.5 mm, or 3.5 mm in height, depending on the prosthetic space and STH. Longitudinal clinical parameters (STH, mucosal thickness, and keratinized mucosa width) and radiographic data [bone remodelling and marginal bone loss (MBL)] were collected at 3, 6, 12, and 24 months postsurgery. The gain in STH was significantly greater around the implants placed in a subcrestal ≈2 mm position. After 2 years, the mean change in bone remodelling in the SA group was significantly greater than in the LA group. According to the multiple linear regression, bone remodelling depends primarily on abutment height (β = -0.43), followed by crestal position (β = 0.34), and keratinized mucosa width (β = -0.22), while MBL depends on abutment height (β = -0.37), and the patient's age (β = -0.36). Implants placed in an equicrestal or subcrestal ≈1 mm position with LA undergo less bone remodelling, while the lowest level of MBL occurs in subcrestal ≈2 mm implants with LA. Differing soft-tissue thicknesses combined with the use of either SA or LA produced significant intergroup differences in bone remodelling and MBL. Abutment height is the most powerful predictor variable affecting bone remodelling and MBL. Depending on the dimensions of the peri‑implant soft-tissue phenotype, placing the implants subcrestally may also be a viable option to decrease bone remodelling and, consequently, reduce MBL. identification number: NCT05670340.

6 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Javier MonteroJavier Montero
Javier Montero
IZIbrahim Dib Zaitun
Ibrahim Dib Zaitun
YGYasmina Guadilla
Yasmina Guadilla
Javier FloresJavier Flores
Javier Flores
BPBeatriz Pardal-Peláez
Beatriz Pardal-Peláez
CGCristina Gómez-Polo
Cristina Gómez-Polo
This study aims to assess the treatment outcomes (functional and subjective) of mandibular overdentures retained on two implants with or without an immediate loading protocol. In this randomized clinical trial, twenty fully edentulous patients were treated with a mandibular two-implant-retained overdenture and a complete new maxillary denture. In half of the sample, the implants were loaded immediately by means of VulkanLoc® abutments after emplacement of the implant, but in the counterparts, these VulkanLoc® abutments were connected to implants two months after the surgery (conventional protocol), and until that time the dentures were retained by healing abutments. Treatment outcomes were assessed at two, six, and twelve months after surgery. Functional outcomes were calculated according to masticatory performance, estimated by the mixed fraction of a two-coloured chewing gum after five, ten, and fifteen chewing strokes, by the occlusal force recorded by pressure-sensitive sheets, and by the bioelectrical muscular activity. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analogue scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study show that new complete dentures resulted in significant improvements in chewing ability, patient satisfaction, and oral health-related quality of life and that subsequent implant-retained overdentures produced further and faster significant improvements. The loading protocol may influence those positive self-reported outcomes rather than the objective functional evaluations.

30 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
SZSara Dib Zakkour
Sara Dib Zakkour
JZJuan Dib Zakkour
Juan Dib Zakkour
YGYasmina Guadilla
Yasmina Guadilla
Javier MonteroJavier Montero
Javier Montero
IZIbrahim Dib Zaitun
Ibrahim Dib Zaitun
The aging population in developed countries has increased the number of edentulous patients and, therefore, the need for prosthetic rehabilitation to improve their quality of life. Complete dentures are the main treatment option in these cases. The use of CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) in dentistry has improved clinical protocols and outcomes, achieving a reduction in work time and economic costs for the patients. The main objective of this review was to compare the characteristics of conventional and digital dentures, attempting to determine whether the use of new technologies represents an improvement in the properties of removable complete dentures. A bibliographic review was carried out in the PubMed/MEDLINE, Cochrane Library, Scielo, and Embase databases. With the initial search, 157 articles were obtained. After applying the inclusion and exclusion criteria, 64 publications were selected for this bibliographic review. The different conclusions of the studies consulted were compared regarding fit and retention, fracture resistance, surface roughness, biocompatibility, and aesthetics, taking into account the different methods of prostheses fabrication. In general, digital prostheses have shown better mechanical properties and, consequently, better biocompatibility and aesthetics than conventional prostheses. However, the obtained results were very heterogeneous, preventing a supported conclusion.