This paper focuses on transits available around the world. AC voltage transits and DC voltage transit are reviewed and compared. Emphasis is given to differences, advantages and disadvantages of voltage supplies and traction types. First, differences between bus rapid transit (BRT), metro, light rail transit (LRT) and light metro are covered, with special attention to statistical of annual passengers per year, an attribute that defines the type of railway transit. Mention is also made to the history of DC and AC overhead wires, other traction preferences for metro transit and highlighted differences between the third rail and fourth rail traction. Malaysian transit systems are then discussed, with special attention to LRT Kelana Jaya line, world's third DC transit that employs the fourth rail traction. The discussion have produced relevant statistical data that this paper is in part aimed at summarizing and at comparing with what accomplished on the same subject within the third rail traction framework. The increased in LRT Kelana Jaya line annual passengers per year is a proof of success for the fourth rail technology.
30 December 2018 in International Journal of Research in Science
This paper presents a study about electric field behaviour of 10kV polymer insulator with moss deposition under foggy condition. The aim of this simulation experiment was to determine if this field affect the initiation of pollution flashover. To study this effect, simulations were carried out using High Frequency Structure Simulator (HFSS). The simulation experiment includes the results of electric field distribution along the insulator and also the magnitude of electric field at three different locations in identifying the parts of the insulator’s surface that likely to initiate pollution flashover. The moss deposited polymer insulator displayed uniformed and considerably intense distribution of electric field with the clean insulator. The field result showed the likelihood in discharging a corona effect. In short, the results indicated that electric field along the insulator surface would likely be influenced by moss deposition and foggy air.
This paper presents a study on the performance of a fourth rail direct current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was replicated and represented by a lightning-induced overvoltage by means of the Rusck model, with the sum of two Heidler functions as its lightning channel base current input, on a perfect conducting ground. This study aims to determine whether an indirect lightning strike has any influence with regard to the performance of the LRT Kelana Jaya line, a fourth rail DC urban transit station arrester. The simulations were carried out using the Electromagnetic Transients Program–Restructured Version (EMTP–RV), which includes the comparison performance results between the 3EB4-010 arrester and PDTA09 arrester when induced by a 90 kA (9/200 µs). The results demonstrated that the PDTA09 arrester showed better coordination with the insulated rail bracket of the fourth rail. It allowed a lower residual voltage and a more dynamic response, eventually resulting in better voltage gradient in the pre-breakdown region and decreased residual voltage ratio in the high current region.
The fourth rail transit is an interesting topic to be shared and accessed by the community within that area of expertise. Several ongoing works are currently being conducted especially in the aspects of system technical performances including the rail bracket component and the sensitivity analyses on the various rail designs. Furthermore, the lightning surge study on railway electrification is significant due to the fact that only a handful of publications are available in this regard, especially on the fourth rail transit. For this reason, this paper presents a study on the electrical performance of a fourth rail Direct Current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was modelled by means of the Rusck model and the sum of two Heidler functions. The simulations were carried out using the EMTP-RV software which included the performance comparison of polymer-insulated rail brackets, namely the Cast Epoxy (CE), the Cycloaliphatic Epoxy A (CEA), and the Glass Reinforced Plastic (GRP) together with the station arresters when subjected by 30 kA (5/80 µs) and 90 kA (9/200 µs) lightning currents. The results obtained demonstrated that the GRP material has been able to slightly lower its induced overvoltage as compared to other materials, especially for the case of 90 kA (9/200 µs), and thus serves better coordination with the station arresters. This improvement has also reflected on the recorded residual voltage and energy absorption capacity of the arrester, respectively.
This paper presents a study on the performance of three different insulated rail bracket materials affected by an indirect lightning strike. The indirect lightning strike was remodelled by means of the Rusck model and the sum of two Heidler function. The simulations were carried out using the EMTP-RV which includes the comparison performance results between the Cast Epoxy, the Cycloaliphatic Epoxy A and the Glass Reinforced Plastic bracket materials with the station arresters when imposed by a 14 kA (0.4/12 µs), The results demonstrated that the Glass Reinforced Plastic material showed a better coordination with the station arresters.