Benjamin Lengenfelder

Mr. Benjamin Lengenfelder


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BLBenjamin Lengenfelder
Benjamin Lengenfelder
FMFanuel Mehari
Fanuel Mehari
MHMartin Hohmann
Martin Hohmann
MHMarkus Heinlein
Markus Heinlein
ECErika Marie Chelales
Erika Marie Chelales
MSMichael Schmidt
Michael Schmidt
Laser surgery is a rising surgical technique, which offers several advantages compared to the traditional scalpel. However, laser surgery lacks a contact-free feedback system which offers high imaging contrast to identify the tissue type ablated and also a high penetration depth. Photoacoustic imaging has the potential to fill this gap. Since photoacoustic detection is commonly contact based, a new non-interferometric detection technique based on speckle-analysis for remote detection is presented in this work. Phantom and ex-vivo experiments are carried out in transmission and reflection-mode for proof of concept. In summary, the potential of the remote speckle sensing technique for photoacoustic detection is demonstrated. In future, this technique might be applied for usage as a remote feedback system for laser surgery, which could help to broaden the applications of lasers as smart surgical tools.

19 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MHMartin Hohmann
Martin Hohmann
DHDamaris Hecht
Damaris Hecht
BLBenjamin Lengenfelder
Benjamin Lengenfelder
MSMoritz Späth
Moritz Späth
FKFlorian Klämpfl
Florian Klämpfl
MSMichael Schmidt
Michael Schmidt
In medical applications, hyper-spectral imaging is becoming more and more common. It has been shown to be more effective for classification and segmentation than normal RGB imaging because narrower wavelength bands are used, providing a higher contrast. However, until now, the fact that hyper-spectral images also contain information about the three-dimensional structure of turbid media has been neglected. In this study, it is shown that it is possible to derive information about the depth of inclusions in turbid phantoms from a single hyper-spectral image. Here, the depth information is encoded by a combination of scattering and absorption within the phantom. Although scatter-dominated regions increase the backscattering for deep vessels, absorption has the opposite effect. With this argumentation, it makes sense to assume that, under certain conditions, a wavelength is not influenced by the depth of the inclusion and acts as an iso-point. This iso-point could be used to easily derive information about the depth of an inclusion. In this study, it is shown that the iso-point exists in some cases. Moreover, it is shown that the iso-point can be used to obtain precise depth information.

1 January 2018
Verified
Conference Paper
Closed access
PDF file
BLBenjamin Lengenfelder
Benjamin Lengenfelder
SASagie Asraf
Sagie Asraf
NONisan Ozana
Nisan Ozana
MSMoritz Späth
Moritz Späth
MSMichael Schmidt
Michael Schmidt
ZZZeev Zalevsky
Zeev Zalevsky
Brillouin scattering is a nonlinear effect in optical fibers which can be used for temperature or strain sensing. For read-out and analysis of the scattered signal, spectrum-analyzers with a very high resolution or complex detection systems are currently needed. In this work, a new detection modality for radial acoustic modes in optical fibers based on speckle-sensing is presented.

1 January 2018
Verified
Conference Paper
Closed access
FMFanuel Mehari
Fanuel Mehari
BLBenjamin Lengenfelder
Benjamin Lengenfelder
RFRobert Figura
Robert Figura
FKFlorian Klämpfl
Florian Klämpfl
MSMichael Schmidt
Michael Schmidt
The analytical technique laser-induced breakdown spectroscopy (LIBS) is becoming an attractive technique in the field of medicine. One emerging application is the differentiation of biological tissues in real-time during laser surgery. This work attempts to further investigate the use of LIBS together with a surgical Er:YAG laser. The main goal here is to investigate the effect of body fluids as potential contaminants during LIBS based differentiation of soft tissues. Furthermore, the work attempts to exploit the use of the surgical laser as a cleaning laser and compares the effect when only the LIBS laser is used for tissue differentiation. The study shows that body fluids have a significant influence on the LIBS spectra and that a surgical laser might serve as an in-vivo cleaner leading to improved tissue classification during laser surgery.

2 April 2020
Verified
Conference Paper
Open access
PDF file
BLBenjamin Lengenfelder
Benjamin Lengenfelder
HJHassan Jarkas
Hassan Jarkas
NSNadav Shabairou
Nadav Shabairou
MHMartin Hohmann
Martin Hohmann
MSMichael Schmidt
Michael Schmidt
FKFlorian Klämpfl
Florian Klämpfl
Photoacoustic imaging is a new, rising imaging technique which combines high penetration depth with a good image contrast. It is demonstrated for the first time that remote photoacoustic sensing by speckle-analysis can be performed in the MHz-sampling range using a low-resolution diode array by showing experimental results. Phantoms and ex-vivo samples are measured in transmission-mode. In addition, the detection sensitivity of the new system is estimated. The new technique might help in future to broaden the applications of photoacoustics in special applications like wound imaging, endoscopy or guiding laser surgeries.

17 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SASagie Asraf
Sagie Asraf
BLBenjamin Lengenfelder
Benjamin Lengenfelder
MSMichael Schmidt
Michael Schmidt
ZZZeev Zalevsky
Zeev Zalevsky
We propose a novel technique for measurements of Brillouin acoustic vibrations based on temporal tracking of back-reflected speckle patterns. The proposed method holds the potential to enhance some of the limiting factors in Brillouin frequency measurements while yielding increased spatial resolution and shorter scanning times of the inspected fiber. Experimental results show the capabilities of the proposed method are presented, using a two pump-waves configuration.