As one of the most widely used units in water cooling systems, the closed wet cooling towers (CWCTs) have two typical counter-flow constructions, in which the spray water flows from the top to the bottom, and the moist air and cooling water flow in the opposite direction vertically (parallel) or horizontally (cross), respectively. This study aims to present a simplified calculation method for conveniently and accurately analyzing the thermal performance of the two types of counter-flow CWCTs, viz. the parallel counter-flow CWCT (PCFCWCT) and the cross counter-flow CWCT (CCFCWCT). A simplified cooling capacity model that just includes two characteristic parameters is developed. The Levenberg–Marquardt method is employed to determine the model parameters by curve fitting of experimental data. Based on the proposed model, the predicted outlet temperatures of the process water are compared with the measurements of a PCFCWCT and a CCFCWCT, respectively, reported in the literature. The results indicate that the predicted values agree well with the experimental data in previous studies. The maximum absolute errors in predicting the process water outlet temperatures are 0.20 and 0.24 °C for the PCFCWCT and CCFCWCT, respectively. These results indicate that the simplified method is reliable for performance prediction of counter-flow CWCTs. Although the flow patterns of the two towers are different, the variation trends of thermal performance are similar to each other under various operating conditions. The inlet air wet-bulb temperature, inlet cooling water temperature, air flow rate, and cooling water flow rate are crucial for determining the cooling capacity of a counter-flow CWCT, while the cooling tower effectiveness is mainly determined by the flow rates of air and cooling water. Compared with the CCFCWCT, the PCFCWCT is much more applicable in a large-scale cooling water system, and the superiority would be amplified when the scale of water distribution system increases. Without multiple iterative calculations and extensive experimental data, the simplified method could be used to effectively analyze the thermal performance of counter-flow CWCTs in operation. It is useful for optimization operation of counter-flow CWCTs such that to improve the energy efficiency of the overall cooling water system.

1 January 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
DHDuan-Jun Han
Duan-Jun Han
CLCan Li
Can Li
XWXiaoqing Wei
Xiaoqing Wei
JYJin-Lin Yang
Jin-Lin Yang
CWChun-Long Wu
Chun-Long Wu
QOQin Ouyang
Qin Ouyang

26 April 2016 in Sustainability
Verified
Journal Article
Open access
PDF file
XWXiaoqing Wei
Xiaoqing Wei
Nianping LiNianping Li
Nianping Li
JPJinqing Peng
Jinqing Peng
JCJianlin Cheng
Jianlin Cheng
LSLin Su
Lin Su
JHJinhua Hu
Jinhua Hu
An existing idle cooling tower can be reversibly used as a heat-source tower (HST) to drive a heat pump (HP) in cold seasons, with calcium chloride (CaCl2) aqueous solution commonly selected as the secondary working fluid in an indirect system due to its good thermo-physical properties. This study analyzed the effect of CaCl2 mass fraction on the effectiveness (ε) of a closed HST and the coefficient of performance (COP) of a HP heating system using an artificial neural network (ANN) technique. CaCl2 aqueous solutions with five different mass fractions, viz. 3%, 9%, 15%, 21%, and 27%, were chosen as the secondary working fluids for the HSTHP heating system. In order to collect enough measured data, extensive field tests were conducted on an experimental test rig in Changsha, China which experiences hot summer and cold winter weather. After back-propagation (BP) training, the three-layer (4-9-2) ANN model with a tangent sigmoid transfer function at the hidden layer and a linear transfer function at the output layer was developed for predicting the tower effectiveness and the COP of the HP under different inlet air dry-/wet-bulb temperatures, hot water inlet temperatures and CaCl2 mass fractions. The correlation coefficient (R), mean relative error (MRE) and root mean squared error (RMSE) were adopted to evaluate the prediction accuracy of the ANN model. The results showed that the R, MRE, and RMSE between the training values and the experimental values of ε (COP) were 0.995 (0.996), 2.09% (1.89%), and 0.005 (0.060), respectively, which indicated that the ANN model was reliable and robust in predicting the performance of the HP. The findings of this paper indicated that in order to guarantee normal operation of the system, the freezing point temperature of the CaCl2 aqueous solution should be sufficiently (3–5 K) below its lowest operating temperature or lower than the normal operating temperature by about 10 K. The tower effectiveness increased with increasing CaCl2 mass fraction from 0 to 27%, while the COP of the HP decreased. A tradeoff between the tower effectiveness and the COP of the HP should be considered to further determine the suitable mass fraction of CaCl2 aqueous solution for the HSTHP heating system. The outputs of this study are expected to provide guidelines for selecting brine with an appropriate mass fraction for a closed HSTHP heating system for actual applications, which would be a reasonable solution to improve the system performance.

1 May 2017 in Building and Environment
Verified
Journal Article
Closed access
JHJinhua Hu
Jinhua Hu
Nianping LiNianping Li
Nianping Li
HYHiroshi Yoshino
Hiroshi Yoshino
UYU Yanagi
U Yanagi
KHKenichi Hasegawa
Kenichi Hasegawa
XWXiaoqing Wei
Xiaoqing Wei

20 May 2017 in Energies
Verified
Journal Article
Open access
PDF file
XWXiaoqing Wei
Xiaoqing Wei
Nianping LiNianping Li
Nianping Li
JPJinqing Peng
Jinqing Peng
JCJianlin Cheng
Jianlin Cheng
JHJinhua Hu
Jinhua Hu
MWMeng Wang
Meng Wang
To minimize the total energy consumption of a cooling tower-assisted heat pump (CTAHP) system in cooling mode, a model-based control strategy with hybrid optimization algorithm for the system is presented in this paper. An existing experimental device, which mainly contains a closed wet cooling tower with counter flow construction, a condenser water loop and a water-to-water heat pump unit, is selected as the study object. Theoretical and empirical models of the related components and their interactions are developed. The four variables, viz. desired cooling load, ambient wet-bulb temperature, temperature and flow rate of chilled water at the inlet of evaporator, are set to independent variables. The system power consumption can be minimized by optimizing input powers of cooling tower fan, spray water pump, condenser water pump and compressor. The optimal input power of spray water pump is determined experimentally. Implemented on MATLAB, a hybrid optimization algorithm, which combines the Limited memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm with the greedy diffusion search (GDS) algorithm, is incorporated to solve the minimization problem of energy consumption and predict the system’s optimal set-points under quasi-steady-state conditions. The integrated simulation tool is validated against experimental data. The results obtained demonstrate the proposed operation strategy is reliable, and can save energy by 20.8% as compared to an uncontrolled system under certain testing conditions.

11 April 2022 in Indoor and Built Environment
Verified
Journal Article
Closed access
CLCan Li
Can Li
HZHuali Zi
Huali Zi
XWXiaoqing Wei
Xiaoqing Wei
JXJiayuan Xiong
Jiayuan Xiong
Airflow improvement in a large industrial building is one of the most effective ways to improve the thermal comfort of workers. Air Diffusion Performance Indices (ADPI) of an industrial workshop area under different air supply angles (15°, 30°, 45°, 60°, 75° and 90° in summer and 90° in winter) of the ceiling-mounted swirling diffusers were evaluated by on-site measurements and computational fluid dynamics (CFD) modelling. The measurement data was used to verify the CFD numerical model. The temperature and velocity field of the working area were simulated and analysed under seven operating conditions of swirling diffusers. The findings showed that in summer, the increase of the swirling air supply angle would increase the air velocity. When the air supply angle was larger than 75°, a draughty wind speed (>0.3 m/s) in the local working area, was produced. When the air supply angle was 30°–75°, the indoor design comfortable temperature range (26°C–28°C) was produced. The ADPIs of the workshop were 100% with the air supply angles of 45° and 60° in summer and 90° in winter, respectively. The research findings should provide a reference for improving the airflow organization in the working area of a tall factory building.