Kenichi Hasegawa

Prof. Kenichi Hasegawa

Akita Prefectural University, Akita, Japan
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Energy and Buildings
Verified
Journal Article
Closed access
Guangtao FanGuangtao Fan
Guangtao Fan
JXJingchao Xie
Jingchao Xie
HYHiroshi Yoshino
Hiroshi Yoshino
UYU Yanagi
U Yanagi
KHKenichi Hasegawa
Kenichi Hasegawa
JLJiaping Liu
Jiaping Liu

6 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
SKSupriya Khadka
Supriya Khadka
Hom Bahadur RijalHom Bahadur Rijal
Hom Bahadur Rijal
AKAMANO KATSUNORI
AMANO KATSUNORI
TSTeruyuki Saito
Teruyuki Saito
HIHikaru Imagawa
Hikaru Imagawa
MTMori Taro
Mori Taro
Comfort temperature is important to investigate because the chosen office indoor temperatures affect the energy used in a building, and a thermally comfortable environment makes the occupants be more productive. The effects of temperature on comfort are broadly recognized for thermal comfort. Japanese office buildings are well equipped with air-conditioning systems to improve the thermal comfort of the occupants. The main objectives of this research were to compare the winter comfort temperature in mixed mode (MM) and heating, ventilation and air-conditioning (HVAC) office buildings and to investigate the relationship between the comfort temperature and the indoor air temperature. This study measured the thermal environmental conditions of the office buildings and surveyed the thermal comfort of the occupants. The field survey was conducted during winter in seven office buildings located in the Aichi prefecture of Japan. In total, 4466 subjective votes were collected from 46 occupants. The result suggested that the occupants were found to be more satisfied with the thermal environment of MM buildings than that of HVAC office buildings. Overall, 95% of comfort temperatures were in the range 22~28 °C in MM and HVAC buildings, which were higher than the indoor temperature of 20 °C recommended by the Japanese government. The comfort temperature was highly correlated to the indoor air temperature of the MM buildings than to that of HVAC buildings. This indicated that the occupants were more adapted towards the given thermal environment of MM buildings.

KIKazuki Izawa
Kazuki Izawa
AKAtsutaka Kubosaki
Atsutaka Kubosaki
NKNaoki Kobayashi
Naoki Kobayashi
Yutaka AkiyamaYutaka Akiyama
Yutaka Akiyama
AYAkiko Yamazaki
Akiko Yamazaki
MWMaiko Watanabe
Maiko Watanabe
Fungal community analyses in homes have been attracting attention because fungi are now generally considered to be allergens. Currently, these analyses are generally conducted using the culture method, although fungal communities in households often contain species that are difficult to culture. In contrast, next-generation sequencing (NGS) represents a comprehensive, labor- and time-saving approach that can facilitate species identification. However, the reliability of the NGS method has not been compared to that of the culture method. In this study, in an attempt to demonstrate the reliability of this application, we used the NGS method to target the internal transcribed spacer 1 (ITS1) in the fungal genome, conducted fungal community analyses for 18 house-dust samples and analyzed fungal community structures. The NGS method positively correlated with the culture method regarding the relative abundance of Aspergillus, Penicillium, Cladosporium and yeasts, which represent the major fungal components found in houses. Furthermore, several genera, such as Malassezia, could be sensitively detected. Our results imply that the reliability of the NGS method is comparable to that of the culture method and indicates that easily available databases may require modifications, including the removal of registrations that have not been sufficiently classified at the genus level.

1 August 2015 in Building and Environment
Verified
Journal Article
Closed access
HZHuibo zhang
Huibo zhang
HYHiroshi Yoshino
Hiroshi Yoshino
AIAtsushi Iwamae
Atsushi Iwamae
KHKenichi Hasegawa
Kenichi Hasegawa

1 May 2017 in Building and Environment
Verified
Journal Article
Closed access
JHJinhua Hu
Jinhua Hu
Nianping LiNianping Li
Nianping Li
HYHiroshi Yoshino
Hiroshi Yoshino
UYU Yanagi
U Yanagi
KHKenichi Hasegawa
Kenichi Hasegawa
XWXiaoqing Wei
Xiaoqing Wei

MWMaiko Watanabe
Maiko Watanabe
RKRumi Konuma
Rumi Konuma
NKNaoki Kobayashi
Naoki Kobayashi
AYAkiko Yamazaki
Akiko Yamazaki
YKYoichi Kamata
Yoichi Kamata
YHYukiko Hara-Kudo
Yukiko Hara-Kudo
To understand fungal contamination in the indoor environment of the disaster region, a field survey was performed to measure the number of fungal counts and identify isolates in the indoor air of prefabricated temporary housing, privately independent-housing, and rented apartments flooded by the East Japan Great Earthquake disaster tsunami. As a result, the period with the highest detected fungal count was from the rainy season to summer in independent-housing and rented apartments. Moreover, in the temporary housing, the fungal number increased further in winter as indicated by the maximum fungal-number throughout the measurement period. The detection frequency of Aspergillus species was relatively higher in the indoor air of temporary housing than in typical housing in the non-disaster area. Since Aspergillus is known as an allergenic genus, it requires careful attention to the health risk for residents. The extremely high level of fungal condensation in indoor air possibly occurred due to high relative humidity and loss of heat insulation in the building attics. It is suggested that this problem commonly happened in the cold region including the entire disaster region of the East Japan Great Earthquake.