jinwoo kim

Mr. jinwoo kim

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2022 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
HKHaemin Kim
Haemin Kim
SYSangyeon Youn
Sangyeon Youn
JKjinwoo kim
jinwoo kim
SPSunghun Park
Sunghun Park
MLMOONHWAN LEE
MOONHWAN LEE
Jin Ho ChangJin Ho Chang
Jin Ho Chang

9 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JJJihun Jang
Jihun Jang
JKjinwoo kim
jinwoo kim
HLHak Jong Lee
Hak Jong Lee
Jin Ho ChangJin Ho Chang
Jin Ho Chang
A combined transrectal ultrasound and photoacoustic (TRUS–PA) imaging probe was developed for the clear visualization of morphological changes and microvasculature distribution in the prostate, as this is required for accurate diagnosis and biopsy. The probe consisted of a miniaturized 128-element 7 MHz convex array transducer with 134.5° field-of-view (FOV), a bifurcated optical fiber bundle, and two optical lenses. The design goal was to make the size of the TRUS–PA probe similar to that of general TRUS probes (i.e., about 20 mm), for the convenience of the patients. New flexible printed circuit board (FPCB), acoustic structure, and optical lens were developed to meet the requirement of the probe size, as well as to realize a high-performance TRUS–PA probe. In visual assessment, the PA signals obtained with the optical lens were 2.98 times higher than those without the lens. Moreover, the in vivo experiment with the xenograft BALB/c (Albino, Immunodeficient Inbred Strain) mouse model showed that TRUS–PA probe was able to acquire the entire PA image of the mouse tight behind the porcine intestine about 25 mm depth. From the ex vivo and in vivo experimental results, it can be concluded that the developed TRUS–PA probe is capable of improving PA image quality, even though the TRUS–PA probe has a cross-section size and an FOV comparable to those of general TRUS probes.

1 July 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
JKjinwoo kim
jinwoo kim
JKJuhwan Kim
Juhwan Kim
HKHaemin Kim
Haemin Kim
Jin Ho ChangJin Ho Chang
Jin Ho Chang
Ultrasound-induced optical clearing microscopy (US-OCM) addresses limited imaging depth in optical microscopy, caused by light scattering in biological tissues. It uses ultrasound-induced gas bubbles to better image biological samples. However, controlling the bubble location using only ultrasound is challenging. This study introduces a novel method, “optrasound,” combining optical and ultrasound energies for precise bubble control. It presents the ultrasound field and uses a focused laser to trigger bubble formation. Optrasound-induced deep microscopy improves light beam width by 3.39 times at a depth of 350 µm because the gas bubbles reduce light scattering. This technique can precisely localize a bubble cloud while matching the US-OCM performance.

28 October 2025 in Ultrasonics
Verified
Journal Article
Closed access
SHSuntae Hwang
Suntae Hwang
JKjinwoo kim
jinwoo kim
ELEunji Lee
Eunji Lee
Jin Ho ChangJin Ho Chang
Jin Ho Chang

17 September 2025 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JKjinwoo kim
jinwoo kim
JKJae Gwang Kwon
Jae Gwang Kwon
HBHyeon Sang Bark
Hyeon Sang Bark
Jin Ho ChangJin Ho Chang
Jin Ho Chang
HKHaemin Kim
Haemin Kim

8 April 2025
Verified
Conference Paper
Closed access
JKjinwoo kim
jinwoo kim
JKJuwon Kwon
Juwon Kwon
JCJin Ho Chang
Jin Ho Chang
Although optical microscopy provides high-resolution optical images, the light causes blur and the energy decreases exponentially, limiting light penetration depth due to the optical scattering. For this reason, we recently proposed and verified that optrasound-induced deep optical microscopy (OPS-DOM) can provide deep optical imaging by using gas bubble combined optical and ultrasound energies. However, due to restrictions in the size of bubbles generated, there are limitations in selectively acquiring 3D optical images at deep depths. In this study, we proposed a method that controlled the size of the gas bubble by changing the ultrasound frequency and measuring the light penetration depth. Through this, it can be presented to freely and selectively control imaging depth for deep optical microscopy.