Mareike Schonhoff

Ms. Mareike Schonhoff

Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
RBRudi G. Bitsch
Rudi G. Bitsch
MSMareike Schonhoff
Mareike Schonhoff
KSKlaus-Arno Siebenrock
Klaus-Arno Siebenrock
MSM. Schwarze
M. Schwarze
SJSebastian Jaeger
Sebastian Jaeger
Adequate primary stability of the acetabular revision construct is necessary for long-term implant survival. The difference in primary stability between tantalum and titanium components is unclear. Six composite hemipelvises with an acetabular defect were implanted with a tantalum augment and cup, using cement fixation between cup and augment. Relative motion was measured at cup/bone, cup/augment and bone/augment interfaces at three load levels; the results were compared to the relative motion measured at the same interfaces of a titanium cup/augment construct of identical dimensions, also implanted into composite bone. The implants showed little relative motion at all load levels between the augment and cup. At the bone/augment and bone/cup interfaces the titanium implants showed less relative motion than tantalum at 30% load (p < 0.001), but more relative motion at 50% (p = n.s.) and 100% (p < 0001) load. The load did not have a significant effect at the augment/cup interface (p = 0.086); it did have a significant effect on relative motion of both implant materials at bone/cup and bone/augment interfaces (p < 0.001). All interfaces of both constructs displayed relative motion that should permit osseointegration. Tantalum, however, may provide a greater degree of primary stability at higher loads than titanium. The clinical implication is yet to be seen

17 May 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
SSStefan Schroeder
Stefan Schroeder
MSMareike Schonhoff
Mareike Schonhoff
MUMaximilian Uhler
Maximilian Uhler
SBSteffen Braun
Steffen Braun
SJSebastian Jaeger
Sebastian Jaeger
JKJ. Philippe Kretzer
J. Philippe Kretzer
Background: Kinematic alignment is an alternative approach to mechanical alignment. Kinematic alignment can restore the joint line to its prearthritic condition, and its advocates have suggested it may be associated with other benefits. But this alignment approach often results in tibial components that are placed in varus and femoral components that are placed in valgus alignment, which may result in an increased risk of component loosening because of wear. Like malaligned implant components, kinematically aligned knee implants could increase wear in vivo, but we lack comparative data about wear behavior between these approaches. Questions/purposes: (1) Do the different alignment approaches (kinematic, mechanical, and purposefully malaligned components) result in different wear rates in a wear simulator? (2) Do the different alignment approaches lead to different worn areas on the polyethylene inserts in a wear simulator? (3) Do the different alignment approaches result in different joint kinematics in a wear simulator? Methods: Mechanical alignment was simulated in a force-controlled manner with a virtual ligament structure according to the International Organization for Standardization (ISO 14243-1) using a knee wear simulator. To simulate kinematic alignment, flexion-extension motion, internal-external torque, and the joint line were tilted by 4°, using a novel mechanical setup, without changing the force axis. The setup includes bearings with inclinations of 4° so that the joint axis of 4° is determined. To verify the angle of 4°, a digital spirit level was used. To simulate malalignment, we tilted the implant and, therefore, the joint axis by 4° using a wedge with an angle of 4° without tilting the torque axes of the simulator. This leads to a purposefully malaligned tibial varus and femoral valgus of 4°. For each condition, three cruciate-retaining knee implants were tested for 3.0 x 106 cycles, and one additional implant was used as soak control. Gravimetric wear analyses were performed every 0.5 x 106 cycles to determine the linear wear rate of each group by linear regression. The wear area was measured after 3.0 x 106 cycles by outlining the worn areas on the polyethylene inserts, then photographing the inserts and determining the worn areas using imaging software. The joint kinematics (AP translation and internal-external rotation) were recorded by the knee simulator software and analyzed during each of the six simulation intervals. Results: Comparing the wear rates of the different groups, no difference could be found between the mechanical alignment and the kinematic alignment (3.8 ± 0.5 mg/million cycles versus 4.1 ± 0.2 mg/million cycles; p > 0.99). However, there was a lower wear rate in the malaligned group (2.7 ± 0.2 mg/million cycles) than in the other two groups (p < 0.01). When comparing the total wear areas of the polyethylene inserts among the three different alignment groups, the lowest worn area could be found for the malaligned group (716 ± 19 mm2; p ≤ 0.003), but there was no difference between kinematic alignment and mechanical alignment (823 ± 19 mm2 versus 825 ± 26 mm2; p > 0.99). Comparing the AP translation, no difference was found between the mechanical alignment, the kinematic alignment, and the malalignment group (6.6 ± 0.1 mm versus 6.9 ± 0.2 mm versus 6.8 ± 0.3 mm; p = 0.06). In addition, the internal-external rotation between mechanical alignment, kinematic alignment, and malalignment also revealed no difference (9.9° ± 0.4° versus 10.2° ± 0.1° versus 10.1° ± 0.6°; p = 0.44). Conclusion: In the current wear simulation study, the wear rates of mechanical alignment and kinematic alignment of 4° were in a comparable range. Clinical Relevance: The results suggest that kinematic alignment with up to 4° of component inclination may give the surgeon confidence that the reconstruction will have good wear-related performance when using a modern cruciate-retaining implant. The malaligned group had the lowest wear rate, which may be a function of the smaller worn area on the inserts compared with the other two alignment groups. This smaller articulation area between the femoral condyles and polyethylene insert could increase the risk of delamination of malaligned components over longer test durations and during high-load activities. For that reason, and because malalignment can cause nonwear-related revisions, malalignment should be avoided. Further in vitro and clinical studies must prove whether the wear simulation of different alignments can predict the wear behavior in vivo.

1 April 2022 in Bone & Joint Research
Verified
Journal Article
Open access
SJSebastian Jaeger
Sebastian Jaeger
MEMarvin Eissler
Marvin Eissler
MSM. Schwarze
M. Schwarze
MSMareike Schonhoff
Mareike Schonhoff
JKJ. Philippe Kretzer
J. Philippe Kretzer
RBRudi G. Bitsch
Rudi G. Bitsch
Aims: One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods: A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results: The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion: From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238.

13 September 2022 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
KKKevin Knappe
Kevin Knappe
Andre LunzAndre Lunz
Andre Lunz
MBMatthias Bülhoff
Matthias Bülhoff
MSMareike Schonhoff
Mareike Schonhoff
TRTobias Renkawitz
Tobias Renkawitz
SJSebastian Jaeger
Sebastian Jaeger
Background: In orthopedic and trauma surgery, pulsatile lavage systems are used to clean soft tissue. This may be necessary in septic surgeries or in case of contaminated wounds after trauma. Positive features such as reduction of bacterial contamination and removal of foreign particles are counterbalanced by negative aspects such as bacterial seeding in deeper tissue layers, damage to various tissues and even cases of air embolism. Purpose: The aim of this prospective experimental in vitro study was to compare impact pressure and flow rate in three different pulsatile lavage systems and to determine, whether these parameters alter their ability to reach deeper soft tissue layers. Methods: To test the penetration of soft tissue, the muscle tissue was flushed with contrast medium instead of saline fluid and afterwards scanned by computed tomography. Results: Impact pressure and flow rate showed significant differences between the different systems. There were no significant differences between the three devices in terms of total penetration volume, but there were significant differences in penetration depth. Conclusion: In this study, we found that higher impact pressure leads to deeper penetration and therefore bacteria are likely to be transferred to deeper tissue layers.

22 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMareike Schonhoff
Mareike Schonhoff
TBTherese Bormann
Therese Bormann
KKKevin Knappe
Kevin Knappe
TRTobias Reiner
Tobias Reiner
LSLinda Stange
Linda Stange
SJSebastian Jaeger
Sebastian Jaeger
A revision surgery can be a complicated procedure. The prevention of the removal of a well-integrated cement mantle can minimize intraoperative complications. With the cement-in-cement technique, the implant will be fixated with a layer of bone cement onto the remaining cement mantle. In our experimental in vitro study, we investigated the effect of cement aging of a cement-in-cement revision construct and regular cement mantle on the bending strength. Two different types of bone cement were tested at four different stages of aging. The Palacos cement showed no significant difference in bending strength at any aging point, regardless of whether it was used primarily or as a cement-in-cement revision. In contrast, the SmartSet MV cement showed a significant difference between the primary and cement-in-cement applications depending on cement aging time. The comparison of the two cement-in-cement structures investigated showed significant differences between the manufacturers depending on the cement aging.

24 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KKKevin Knappe
Kevin Knappe
RBRudi G. Bitsch
Rudi G. Bitsch
MSMareike Schonhoff
Mareike Schonhoff
TWTilman Walker
Tilman Walker
TRTobias Renkawitz
Tobias Renkawitz
SJSebastian Jaeger
Sebastian Jaeger
In cemented joint arthroplasty, state-of-the-art cementing techniques include high-pressure pulsatile saline lavage prior to cementation. Even with its outstanding importance in cementation, there are surprisingly few studies regarding the physical parameters that define pulsatile lavage systems. To investigate the parameters of impact pressure, flow rate, frequency and the cleaning effect in cancellous bone, we established a standardized laboratory model. Standardized fat-filled carbon foam specimens representing human cancellous bone were cleaned with three different high-pressure pulsatile lavage systems. Via CT scans before and after cleaning, the cleaning effect was evaluated. All systems showed a cleaning depth of at least 3.0 mm and therefore can be generally recommended to clean cancellous bone in cemented joint arthroplasty. When comparing the three lavage systems, the study showed significant differences regarding cleaning depths and volume, with one system being superior to its peer systems. Regarding the physical parameters, high impact pressure in combination with high flow rate and longer distance to the flushed object seems to be the best combination to improve the cleaning of cancellous bone and therefore increase the chances of a deeper cement penetration that is required in cemented joint arthroplasty. In summary, this study provides the first standardized comparison of different lavage systems and thus gives initial guidance on how to optimally prepare cancellous bone for cemented joint arthroplasty.