Adequate primary stability of the acetabular revision construct is necessary for long-term implant survival. The difference in primary stability between tantalum and titanium components is unclear. Six composite hemipelvises with an acetabular defect were implanted with a tantalum augment and cup, using cement fixation between cup and augment. Relative motion was measured at cup/bone, cup/augment and bone/augment interfaces at three load levels; the results were compared to the relative motion measured at the same interfaces of a titanium cup/augment construct of identical dimensions, also implanted into composite bone. The implants showed little relative motion at all load levels between the augment and cup. At the bone/augment and bone/cup interfaces the titanium implants showed less relative motion than tantalum at 30% load (p < 0.001), but more relative motion at 50% (p = n.s.) and 100% (p < 0001) load. The load did not have a significant effect at the augment/cup interface (p = 0.086); it did have a significant effect on relative motion of both implant materials at bone/cup and bone/augment interfaces (p < 0.001). All interfaces of both constructs displayed relative motion that should permit osseointegration. Tantalum, however, may provide a greater degree of primary stability at higher loads than titanium. The clinical implication is yet to be seen
To compare biomechanical and clinical outcome of laterally wedged insoles (LWI) and an ankle-foot orthosis (AFO) in patients with medial knee osteoarthritis. Single-centre, block-randomized, cross-over controlled trial. Outpatient clinic. About 39 patients with symptomatic medial knee osteoarthritis. Patients started with either LWI or AFO, determined randomly, and six weeks later changed to the alternative. Change in the 1st maximum of external knee adduction moment (eKAM) was assessed with gait analysis. Additional outcomes were other kinetic and kinematic changes and the patient-reported outcomes EQ-5D-5L, Oxford Knee Score (OKS), American Knee Society Clinical Rating System (AKSS), Hannover Functional Ability Questionnaire – Osteoarthritis and knee pain. Mean age (SD) of the study population was 58 (8) years, mean BMI 30 (5). Both aids significantly improved OKS (LWI P = 0.003, AFO P = 0.001), AKSS Knee Score (LWI P = 0.01, AFO P = 0.004) and EQ-5D-5L Index (LWI P = 0.001, AFO P = 0.002). AFO reduced the 1st maximum of eKAM by 18% (P < 0.001). The LWI reduced both maxima by 6% (P = 0.02, P = 0.03). Both AFO and LWI reduced the knee adduction angular impulse (KAAI) by 11% (P < 0.001) and 5% (P = 0.05) respectively. The eKAM (1st maximum) and KAAI reduction was significantly larger with AFO than with LWI (P = 0.001, P = 0.004). AFO reduces medial knee load more than LWI. Nevertheless, no clinical superiority of either of the two aids could be shown.
Aims: One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods: A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results: The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion: From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238.
15 July 2019 in Rehabilitation Research and Practice
Objective. To date there is only limited knowledge about the wearing time of orthoses. Ankle-foot orthoses (AFOs) have not been studied with this research question. Additional influences of the orthotic design as well as weekdays and the weekend are also unknown. Design. Monocentric, clinically prospective intervention study. Patients. Inclusion of 10 patients with bilateral spastic cerebral palsy. Methods. Equipment of all subjects with a dynamic ankle-foot orthosis (DAFO) and modular shank supply (MSS, dynamic elastic shank adaptation or ground reaction AFO). Integration of temperature sensors for recording the wearing time for a period of 3 months. Results. The actual wearing time was below the recommendations on actually worn days as well as the average of the entire study period. In addition, the actual usage in terms of days and hours was well below the recommendations. The wearing time showed differences between weekdays and weekend. Differences between DAFO and MSS were not detectable. Conclusion. The actual usage behavior of ankle-foot orthoses differs from the recommendations of the prescriber. This applies to both DAFOs and modular use with shank supplies. Environmental factors may have a significant impact on wearing times on weekdays and the weekend.