The 48V bus converter has been gradually adopted in intermediate bus architecture. The ever-growing development of data centers consumes significant power, and thereby pushing power converters to be more efficient. This paper focuses on the optimization of the transformer for a LLC resonant converter used in data centers, which is the second stage operating as a DC transformer to realize the isolation and a fixed voltage step-down ratio. The front stage is a multiphase buck converter. The magnetic core geometry reported in this paper for the LLC enables a single turn for both primary and secondary windings. Compared with the previous research, the improved interleaving winding scheme benefits from reduced conduction path, lower AC resistance and smaller core volume. Ansys 3D simulation performs the design and optimization of the magnetic core. The proposed magnetic core, winding layout and design optimization are verified in the 30/5V 660W LLC resonant converter. It has higher current stress, but achieves a higher efficiency of 97.7%, better thermal performance, and lower components count than the state-of-the-arts.
30 January 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Dual active bridge (DAB) topology has been recognized as the key circuit for the next generation of high-frequency-link power conversion systems. In order to realize desired operating performance, DAB modulation strategies need to be selected carefully. Different modulation strategies have been considered and combined into a hybrid one, which is able to fully optimize performance. However, to develop a hybrid modulation strategy, the conventional methods including harmonic model and piecewise model have difficulty in balancing modeling accuracy and manpower burden. Although recent data-driven modulation approaches can automate the design process, the accuracy of data-driven models decreases nontrivially with the existence of outliers and without sufficient data. Hence, to alleviate human-dependence and improve modeling accuracy, this paper proposes an AI-based design with data trimming (AI-DT) for hybrid phase shift modulation. Two two-degree-of-freedom modulation strategies are considered for the sake of optimal current stress performance. AI-DT firstly adopts the one-class support vector machine (SVM) to exclude outliers. Second, the state-of-the-art extreme gradient boosting (XGBoost), which is insensitive to training data size, is adopted to build data-driven current stress models for the DAB converter. After that, differential evolution (DE) algorithm helps to choose modulation strategy and optimize modulation parameters for optimal current stress. Generally, the proposed AI-DT is developed in an automated fashion, which largely relieves manual computational complexity while exhibiting satisfactory modulation accuracy. The effectiveness of the proposed AI-DT approach has been experimentally verified with a 1kW hardware prototype, realizing optimal current stress under full operating conditions with more than 96.5% as peak efficiency.
29 January 2020 in IEEE Transactions on Industrial Electronics
With the trend towards achieving high efficiency, high power density and high operating frequency in power converters, a new circuit architecture is proposed in this paper for high step-up photovoltaic applications. This converter consists of a current-fed resonant push-pull converter (PP) as a DC transformer (DCX) dealing with most of power with high efficiency and an active clamp flyback converter (ACF) as a regulator within a large conversion range. As a single stage converter, the ACF regulator is paralleled with PP converter to share the total power and regulates the high output voltage. An experimental prototype with an input voltage range of 24 V—32 V and output 400 V/400 W is built under 1 MHz switching frequency. A peak efficiency of 97.1% and a power density of 210 W/in3 (or 13 W/cm3) are achieved. Experimental result validates the correctness of the analysis and proves the feasibility of the proposed converter for MHz high step-up DC-DC conversion.
10 August 2021 in IEEE Transactions on Industrial Electronics
Splitting and placing interfacing inductance on both sides of the transformer has been proven to be an effective method, which extends the zero-voltage switching region for all the switching devices in the dual active bridge (DAB) converter. With the trend toward operating in higher frequency, achieving higher power density and higher efficiency, the converter model becomes more complex due to the non-negligible parasitic components that brings new challenges to DAB converter design. Traditional analytical methods have made it hard to imitate the proposed converter easily and precisely. Thus, artificial intelligence techniques are able to be utilized to assist the design process. When considering the converter system as a gray-box model, the metaheuristic algorithm can be implemented for the targeted design inside such a gray-box. In this article, a genetic algorithm (GA) is employed in the DAB converter parametric design with an explicit fitness desire to help in discovering the high frequency oscillation (HFO) problem. Consequently, the splitting inductance tuning method is proposed for eliminating the HFO problem and minimizing inductors’ loss. The methodology of implementing GA into converter parametric design, and the proposed splitting inductance tuning method are introduced and verified with a 1 MHz gallium nitride high-electron-mobility transistor based DAB converter prototype. The comparitive experimental results prove the effectiveness of the splitting inductance tuning method and achieve 4% efficiency enhancement with 200 W power delivering.
10 October 2023 in IEEE Transactions on Power Electronics
The role of data centers has become significant in the era of information technology, and their operation consumes a substantial amount of energy. Therefore, the point-of-load (POL) converter or voltage regulation module (VRM) used in data centers must have high efficiency and power density to deliver a large current to specific servers. A common bus voltage 48V at the rack stage needs to be stepped down to intermediate bus voltage, which is 6-5V in this case. To achieve this, a new pentacentra transformer was developed for a 4-phase LLC converter. A centra bar serving as the 5 th leg of the core is added to the conventional 4-leg matrix transformer. The interleaving and integration of windings in the proposed pentacentra transformer enabled balanced current sharing and reduced conduction loss by 45% compared to the traditional winding layout. The experimental prototype of the converter was designed to achieve 800 W power output at a switching frequency of 500 kHz and 48V-40V/6V-5V voltage conversion. The peak efficiency achieves 98.1% along with the power density of 240 W/in 3 with the experimental result. Without the heatsink, the whole converter is operating at rated power within a safe temperature lower than 86 °. The excellent thermal performance ensures the reliable operation of the converter and promises a larger power delivery capability.