Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2–12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters. LiF:Mg,Ti dosimeters (TLD-100) were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV) and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0–10 Gy in step of 2Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy. The TLD-100 dose-response curves were obtained. In the dose range of 0–10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05). This study demonstrates that the TLD dose response, for doses ≤10Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.
1 June 2017 in Journal of Environmental Radioactivity
Radon is a major source of ionizing radiation exposure for the general population. It is known that exposure to radon is a risk factor for the onset of lung cancer. In this study, the results of a radon survey conducted in all districts of a Public Healthcare in Italy, are reported. Measurements of indoor radon were performed using nuclear track detectors, CR-39. The entire survey was conducted according to a well-established quality assurance program. The annual effective dose and excess lifetime cancer risk were also calculated. Results show that the radon concentrations varied from 7 ± 1 Bq/m3 and 5148 ± 772 Bq/m3, with a geometric mean of 67 Bq/m3 and geometric standard deviation of 2.5. The annual effective dose to workers was found to be 1.6 mSv/y and comparable with the worldwide average. In Italy, following the transposition of the European Directive 59/2013, great attention was paid to the radon risk in workplaces. The interest of the workers of the monitored sites was very high and this, certainly contributed to the high return rate of the detectors after exposure and therefore, to the presence of few missing data. Although it was not possible to study the factors affecting radon concentrations, certainly the main advantage of this study is that it was the first in which an entire public health company was monitored in regards to all the premises on the underground and ground floor.
In recent years, stereotactic body radiation therapy (SBRT) has gained popularity among clinical methods for the treatment of medium and low risk prostate cancer (PCa), mainly as an alternative to surgery. The hypo-fractionated regimen allows the administration of high doses of radiation in a small number of fractions; such a fractionation is possible by exploiting the different intrinsic prostate radiosensitivity compared with the surrounding healthy tissues. In addition, SBRT treatment guaranteed a better quality of life compared with surgery, avoiding risks, aftermaths, and possible complications. At present, most stereotactic prostate treatments are performed with the CyberKnife (CK) system, which is an accelerator exclusively dedicated for stereotaxis and it is not widely spread in every radiotherapy centre like a classic linear accelerator (LINAC). To be fair, a stereotactic treatment is achievable also by using a LINAC through Volumetric Modulated Arc Therapy (VMAT), but some precautions must be taken. The aim of this work is to carry out a dosimetric comparison between these two methodologies. In order to pursue such a goal, two groups of patients were selected at Instituto Nazionale Tumori—IRCCS Fondazione G. Pascale: the first group consisting of ten patients previously treated with a SBRT performed with CK; the second one was composed of ten patients who received a hypo-fractionated VMAT treatment and replanned in VMAT-SBRT flattening filter free mode (FFF). The two SBRT techniques were rescaled at the same target coverage and compared by normal tissue sparing, dose distribution parameters and delivery time. All organs at risk (OAR) constraints were achieved by both platforms. CK exhibits higher performances in terms of dose delivery; nevertheless, the general satisfying dosimetric results and the significantly shorter delivery time make VMAT-FFF an attractive and reasonable alternative SBRT technique for the treatment of localized prostate cancer.
The population is continuously exposed to a background level of ionizing radiation due to the natural radioactivity and, in particular, with radon ( 222 Rn). Radon gas has been classified as the second leading cause of lung cancer after tobacco smoke [1]. In the confined environment, radon concentration can reach harmful level and vary accordingly to many factors. Since the primary source of radon in dwellings is the subsurface, the risk assessment and reduction cannot disregard the identification of the local geology and the environmental predisposing factors. In this article, we propose a new methodology, based on the computation of the Gini coefficients at different spatial scales, to estimate the spatial correlation and the geographical variability of radon concentrations. This variability can be interpreted as a signature of the different subsurface geological conditions. The Gini coefficient computation is a statistical tool widely used to determine the degree of inhomogeneity of different kinds of distributions. We generated several simulated radon distributions, and the proposed tool has been validated by comparing the variograms based on the semi-variance computation with those ones based on the Gini coefficient. The Gini coefficient variogram is shown to be a good estimator of the inhomogeneity degree of radon concentration. Indeed, it allows to better constrain the critical distance below which the radon geological source can be considered as uniform at least for the investigated length scales of variability; it also better discriminates the fluctuations due to the environmental predisposing factors from those ones due to the random spatially uncorrelated noise.