Majid Amin Afshar

Dr. Majid Amin Afshar

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
DYDajing Yuan
Dajing Yuan
AAAlexandre H. C. Anthis
Alexandre H. C. Anthis
MAMajid Amin Afshar
Majid Amin Afshar
NPNadezda Pankratova
Nadezda Pankratova
MCMaría Cuartero
María Cuartero
EBEric Bakker
Eric Bakker

13 June 2013 in Analytical Chemistry
Verified
Journal Article
Open access
EGEwa Grygolowicz-Pawlak
Ewa Grygolowicz-Pawlak
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
MAMajid Amin Afshar
Majid Amin Afshar
GMGünter Mistlberger
Günter Mistlberger
EBEric Bakker
Eric Bakker
Potentiometric sensors that exhibit a non-Hofmeister selectivity sequence are normally designed by selective chemical recognition elements in the membrane. In other situations, when used as detectors in separation science, for example, membranes that respond equally to most ions are preferred. With so-called liquid membranes, a low selectivity is difficult to accomplish since these membranes are intrinsically responsive to lipophilic species. Instead, the high solubility of sample lipids in an ionophore-free sensing matrix results in a deterioration of the response. We explore here potentiometric sensors on the basis of ion-exchange membranes commonly used in fuel cell applications and electrodialysis, which have so far not found their way into the field of ion-selective electrodes. These membranes act as Donnan exclusion membranes as the ions are not stripped of their hydration shell as they interact with the membrane. Because of this, lipophilic ions are no longer preferred over hydrophilic ones, making them promising candidates for the detection of abundant ions in the presence of lipophilic ones or as detectors in separation science. Two types of cation-exchanger membranes and one anion-exchange membrane were characterized, and potentiometric measuring ranges were found to be Nernstian over a wide range down to about 10 μM concentrations. Depending on the specific membrane, lipophilic ions gave equal response to hydrophilic ones or were even somewhat discriminated. The medium and long-term stability and reproducibility of the electrode signals were found to be promising when evaluated in synthetic and whole blood samples.

4 November 2012 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
GCGastón A. Crespo
Gastón A. Crespo
MAMajid Amin Afshar
Majid Amin Afshar
EBEric Bakker
Eric Bakker

1 January 2012 in Microchemical Journal
Verified
Journal Article
Closed access
MSMajid Soleimani
Majid Soleimani
SGServeh Ghaderi
Serveh Ghaderi
MAMajid Amin Afshar
Majid Amin Afshar
SSSaeed Soleimani
Saeed Soleimani

1 May 2011 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
MSMajid Soleimani
Majid Soleimani
MMMohamad Saleh Mahmodi
Mohamad Saleh Mahmodi
AMAli Morsali
Ali Morsali
AKAzam Khani
Azam Khani
MAMajid Amin Afshar
Majid Amin Afshar

4 October 2012 in Analytical Chemistry
Verified
Journal Article
Open access
MAMajid Amin Afshar
Majid Amin Afshar
Gaston A. CrespoGaston A. Crespo
Gaston A. Crespo
EBEric Bakker
Eric Bakker
Ion-selective membranes based on porous polypropylene membranes doped with an ionophore and a lipophilic cation-exchanger are used here in a new tandem measurement mode that combines dynamic electrochemistry and zero current potentiometry into a single protocol. Open circuit potential measurements yield near-Nernstian response slopes in complete analogy to established ion-selective electrode methodology. Such measurements are well established to give direct information on the so-called free ion concentration (strictly, activity) in the sample. The same membrane is here also operated in a constant current mode, in which the localized ion depletion at a transition time is visualized by chronopotentiometry. This dynamic electrochemistry methodology gives information on the labile ion concentration in the sample. The sequential protocol is established on potassium and calcium ion-selective membranes. An increase of the ionophore concentration in the membrane to 180 mM makes it possible to determine calcium concentrations as high as 3 mM by chronopotentiometry, thereby making it possible to directly detect total calcium in undiluted blood samples. Recovery times after current perturbation depend on the current amplitude but can be kept to below 1 min for the polypropylene based ion-selective membranes studied here. Plasticized PVC as membrane material is less suited for this protocol, especially when the measurement at elevated concentrations is desired. An analysis of current amplitudes, transition times, and concentrations shows that the data are described by the Sand equation and that migration effects are insignificant. A numerical model describes the experimental findings with good agreement and gives guidance on the required selectivity in order to observe a well-resolved transition time and on the expected errors due to insufficient selectivity. The simulations suggest that the methodology compares well to that of open circuit potentiometry, despite giving complementary information about the sample. The tandem methodology is demonstrated in a titration of calcium with nitrilotriacetic acid (NTA) and in the direct detection of calcium in undiluted heparinized and citrated blood.