Alberto Rubio-Peirotén

Mr. Alberto Rubio-Peirotén

Universidad San Jorge
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2023 in Sleep Medicine
Verified
Journal Article
Closed access
TPT.S. Palsson
T.S. Palsson
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
VDV. Doménech-García
V. Doménech-García

1 July 2022 in The Korean Journal of Pain
Verified
Journal Article
Open access
PDF file
VGVictor Doménech García
Victor Doménech García
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
MIMiren Lecea Imaz
Miren Lecea Imaz
TPThorvaldur Skuli Palsson
Thorvaldur Skuli Palsson
Pablo HerreroPablo Herrero
Pablo Herrero
Pablo Bellosta-LópezPablo Bellosta-López
Pablo Bellosta-López
Víctor Doménech-García, Alberto Rubio Peirotén, Miren Lecea Imaz, Thorvaldur Skuli Palsson, Pablo Herrero, and Pablo Bellosta-López. Korean J Pain 2022;35:240-9. https://doi.org/10.3344/kjp.2022.35.3.240

Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
Felipe García-PinillosFelipe García-Pinillos
Felipe García-Pinillos
Diego Jaén-CarrilloDiego Jaén-Carrillo
Diego Jaén-Carrillo
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
Luis Enrique Roche SeruendoLuis Enrique Roche Seruendo
Luis Enrique Roche Seruendo
The influence of the morphologic characteristics of connective tissue, which plays an essential role during sports activities, on sporting tasks needs further research given the controversial findings reported in the literature. This study aimed at examining the relationship between lower limb connective tissue morphology and drop jump reactivity and determining the influence of sex and athletic performance level. A total of 30 men and 14 women, runners, executed 6 drop jumps (3 × 20 cm and 30 cm height respectively) and their thickness and cross-sectional area were recorded for Achilles and patellar tendons and plantar fascia. No significant results were found in the relationship between the morphology of the connective tissue and reactivity strength index for both sexes. Significant sex differences were found, while women showed greater values (p < 0.005) for Achilles tendon and plantar fascia; men showed greater values for reactivity strength index and drop jump performance (p < 0.001). The present study shows a limited relationship between connective tissue morphology and drop jump reactivity. Additionally, women showed greater normalized values for Achilles tendon and plantar fascia, and men showed greater reactivity strength index and jumping performance values. No relationships between athletic performance level and connective tissue were found.

15 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
Felipe García-PinillosFelipe García-Pinillos
Felipe García-Pinillos
Jorge Royo BorruelJorge Royo Borruel
Jorge Royo Borruel
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
Diego Jaén-CarrilloDiego Jaén-Carrillo
Diego Jaén-Carrillo
Luis Enrique Roche SeruendoLuis Enrique Roche Seruendo
Luis Enrique Roche Seruendo
Wearable technology has allowed for the real-time assessment of mechanical work employed in several sporting activities. Through novel power metrics, Functional Threshold Power have shown a reliable indicator of training intensities. This study aims to determine the relationship between mean power output (MPO) values obtained during three submaximal running time trials (i.e., 10 min, 20 min, and 30 min) and the functional threshold power (FTP). Twenty-two recreationally trained male endurance runners completed four submaximal running time trials of 10, 20, 30, and 60 min, trying to cover the longest possible distance on a motorized treadmill. Absolute MPO (W), normalized MPO (W/kg) and standard deviation (SD) were calculated for each time trial with a power meter device attached to the shoelaces. All simplified FTP trials analyzed (i.e., FTP10, FTP20, and FTP30) showed a significant association with the calculated FTP (p < 0.001) for both MPO and normalized MPO, whereas stronger correlations were found with longer time trials. Individual correction factors (ICF% = FTP60/FTPn) of ~90% for FTP10, ~94% for FTP20, and ~96% for FTP30 were obtained. The present study procures important practical applications for coaches and athletes as it provides a more accurate estimation of FTP in endurance running through less fatiguing, reproducible tests.

24 July 2022 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
Luis Enrique Roche SeruendoLuis Enrique Roche Seruendo
Luis Enrique Roche Seruendo
EMElena Mainer-Pardos
Elena Mainer-Pardos
Hadi NobariHadi Nobari
Hadi Nobari
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
Felipe García-PinillosFelipe García-Pinillos
Felipe García-Pinillos
Background: The advent of power meters for running has raised the interest of athletes and coaches in new ways of assessing changes in running performance. The aim of this study is to determine the changes in power-related variables during and after a strenuous endurance running time trial. Methods: Twenty-one healthy male endurance runners, with a personal record of 37.2 ± 1.2 min in a 10-km race, completed a 1-h run on a motorized treadmill trying to cover as much distance as they could. Before and after the time trial the athletes were asked to perform a 3-min run at 12 km h−1. Normalized mean power output, step frequency, form power and running effectiveness were calculated using the Stryd™ power meter. Heart rate (HR) and rating of perceived exertion (RPE) were monitored, and data averaged every 5 min. Results: Despite high levels of exhaustion were reached during the time trial (HRpeak = 176.5 ± 9.8 bpm; RPE = 19.2 ± 0.8), the repeated measures ANOVA resulted in no significant differences (p ≥ 0.05), between each pair of periods for any of the power-related variables. The pairwise comparison (T test) between the non-fatigued and fatigued constant 3-min runs showed an increase in step frequency (p = 0.012) and a decrease in form power (p < 0.001) under fatigue conditions, with no meaningful changes in normalized mean power output and running effectiveness. Conclusions: Trained athletes are able to maintain power output and running effectiveness during a high demanding extended run. However, they preferred to reduce the intensity of vertical impacts under fatigue conditions by increasing their step frequency.

27 April 2024 in Sports
Verified
Journal Article
Open access
PDF file
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
AMAlejandro Molina-Molina
Alejandro Molina-Molina
APAndrés Ráfales Perucha
Andrés Ráfales Perucha
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
The assessment of leg asymmetries is gaining scientific interest due to its potential impact on performance and injury development. Athletes around puberty exhibit increased gait variability due to a non-established running pattern. This study aims to describe the asymmetries in the spatiotemporal running parameters in developmentally aged athletes. Forty athletes under 14 (U14) (22 females and 18 males) were assessed running on a treadmill at constant speeds of 12 and 14 km·h−1 for 3 min. Step length, step frequency, along with contact (CT) and flight time, both in absolute values and as a percentage of step time, were recorded using a RunScribe sensor attached to the laces of each shoe. U14 runners exhibited high bilateral symmetry in the spatiotemporal parameters of running, with mean asymmetry values (1–5.7%) lower than the intra-limb coefficient of variation (1.7–9.6%). Furthermore, bilateral asymmetries did not vary between the two speeds. An individual-based interpretation of asymmetries identified subjects with consistent asymmetries at both speeds, particularly in terms of CT and contact ratio (%, CT/step time). This study confirms the high symmetry of pubertal runners and paves the way for the application of portable running assessment technology to detect asymmetries on an individual basis.