Silvia Cardiel-Sánchez

Mrs. Silvia Cardiel-Sánchez

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Diego Jaén-CarrilloDiego Jaén-Carrillo
Diego Jaén-Carrillo
Luis Enrique Roche SeruendoLuis Enrique Roche Seruendo
Luis Enrique Roche Seruendo
AMAlejandro Molina-Molina
Alejandro Molina-Molina
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
Felipe García-PinillosFelipe García-Pinillos
Felipe García-Pinillos
Several studies have already analysed power output in running or the relation between VO2max and power production as factors related to running economy; however, there are no studies assessing the difference in power output between shod and barefoot running. This study aims to identify the effect of footwear on the power output endurance runner. Forty-one endurance runners (16 female) were evaluated at shod and barefoot running over a one-session running protocol at their preferred comfortable velocity (11.71 ± 1.07 km·h−1). The mean power output (MPO) and normalized MPO (MPOnorm), form power, vertical oscillation, leg stiffness, running effectiveness and spatiotemporal parameters were obtained using the Stryd™ foot pod system. Additionally, footstrike patterns were measured using high-speed video at 240 Hz. No differences were noted in MPO (p = 0.582) and MPOnorm (p = 0.568), whereas significant differences were found in form power, in both absolute (p = 0.001) and relative values (p < 0.001), running effectiveness (p = 0.006), stiffness (p = 0.002) and vertical oscillation (p < 0.001). By running barefoot, lower values for contact time (p < 0.001) and step length (p = 0.003) were obtained with greater step frequency (p < 0.001), compared to shod running. The prevalence of footstrike pattern significantly differs between conditions, with 19.5% of runners showing a rearfoot strike, whereas no runners showed a rearfoot strike during barefoot running. Running barefoot showed greater running effectiveness in comparison with shod running, and was consistent with lower values in form power and lower vertical oscillation. From a practical perspective, the long-term effect of barefoot running drills might lead to increased running efficiency and leg stiffness in endurance runners, affecting running economy.

27 April 2024 in Sports
Verified
Journal Article
Open access
PDF file
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
AMAlejandro Molina-Molina
Alejandro Molina-Molina
APAndrés Ráfales Perucha
Andrés Ráfales Perucha
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
The assessment of leg asymmetries is gaining scientific interest due to its potential impact on performance and injury development. Athletes around puberty exhibit increased gait variability due to a non-established running pattern. This study aims to describe the asymmetries in the spatiotemporal running parameters in developmentally aged athletes. Forty athletes under 14 (U14) (22 females and 18 males) were assessed running on a treadmill at constant speeds of 12 and 14 km·h−1 for 3 min. Step length, step frequency, along with contact (CT) and flight time, both in absolute values and as a percentage of step time, were recorded using a RunScribe sensor attached to the laces of each shoe. U14 runners exhibited high bilateral symmetry in the spatiotemporal parameters of running, with mean asymmetry values (1–5.7%) lower than the intra-limb coefficient of variation (1.7–9.6%). Furthermore, bilateral asymmetries did not vary between the two speeds. An individual-based interpretation of asymmetries identified subjects with consistent asymmetries at both speeds, particularly in terms of CT and contact ratio (%, CT/step time). This study confirms the high symmetry of pubertal runners and paves the way for the application of portable running assessment technology to detect asymmetries on an individual basis.

7 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
APAndrés Ráfales Perucha
Andrés Ráfales Perucha
EVElisa Bravo Viñuales
Elisa Bravo Viñuales
AMAlejandro Molina-Molina
Alejandro Molina-Molina
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
Luis Enrique Roche SeruendoLuis Enrique Roche Seruendo
Luis Enrique Roche Seruendo
The evaluation of gait biomechanics using portable inertial measurement units (IMUs) offers real-time feedback and has become a crucial tool for detecting gait disorders. However, many of these devices have not yet been fully validated. The aim of this study was to assess the concurrent validity and relative reliability of the RunScribe™ system for measuring spatiotemporal gait parameters during walking. A total of 460 participants (age: 36 ± 13 years; height: 173 ± 9 cm; body mass: 70 ± 13 kg) were asked to walk on a treadmill at 5 km·h−1. Spatiotemporal parameters of step frequency (SF), step length (SL), step time (ST), contact time (CT), swing time (SwT), stride time (StT), stride length (StL) and normalized stride length (StL%) were measured through RunScribe™ and OptoGait™ systems. Bland–Altman analysis indicated small systematic biases and random errors for all variables. Pearson correlation analysis showed strong correlations (0.70–0.94) between systems. The intraclass correlation coefficient supports these results, except for contact time (ICC = 0.64) and swing time (ICC = 0.34). The paired t-test showed small differences in SL, StL and StL% (≤0.25) and large in CT and SwT (1.2 and 2.2, respectively), with no differences for the rest of the variables. This study confirms the accuracy of the RunScribe™ system for assessing spatiotemporal parameters during walking, potentially reducing the barriers to continuous gait monitoring and early detection of gait issues.

14 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Antonio Cartón-LlorenteAntonio Cartón-Llorente
Antonio Cartón-Llorente
Alberto Rubio-PeiroténAlberto Rubio-Peirotén
Alberto Rubio-Peirotén
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
Luis Enrique Roche SeruendoLuis Enrique Roche Seruendo
Luis Enrique Roche Seruendo
Diego Jaén-CarrilloDiego Jaén-Carrillo
Diego Jaén-Carrillo
Participants in trail running races must carry their equipment throughout the race. This additional load modifies running biomechanics. Novel running powermeters allow further analyses of key running metrics. This study aims to determine the acute effects of running with extra weights on running power generation and running kinematics at submaximal speed. Fifteen male amateur trail runners completed three treadmill running sessions with a weighted vest of 0-, 5-, or 10% of their body mass (BM), at 8, 10, 12, and 14 km·h−1. Mean power output (MPO), leg spring stiffness (LSS), ground contact time (GCT), flight time (FT), step frequency (SF), step length (SL), vertical oscillation (VO), and duty factor (DF) were estimated with the Stryd wearable system. The one-way ANOVA revealed higher GCT and MPO and lower DF, VO, and FT for the +10% BM compared to the two other conditions (p < 0.001) for the running speeds evaluated (ES: 0.2–7.0). After post-hoc testing, LSS resulted to be higher for +5% BM than for the +10% and +0% BM conditions (ES: 0.2 and 0.4). Running with lighter loads (i.e., +5% BM) takes the principle of specificity in trail running one step further, enhancing running power generation and LSS.

22 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IAIsabel Albarova-Corral
Isabel Albarova-Corral
ÓAÓscar Alonso-Ezpeleta
Óscar Alonso-Ezpeleta
SPSantiago Poc-Sola
Santiago Poc-Sola
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
Andoni Carrasco-UribarrenAndoni Carrasco-Uribarren
Andoni Carrasco-Uribarren
MMMiguel Malo-Urriés
Miguel Malo-Urriés
Background: In daily clinical practice, patients often refer temporomandibular or cervical complaints after different oral procedures, especially in lengthy procedures that can result in iatrogenic postures or trauma that can affect the temporomandibular joint (TMJ). This study aimed to evaluate the clinical and functional changes of the temporomandibular joint (TMJ) and cervical region immediately after a session of root canal therapy. Methods: Twenty-nine subjects who received a session of root canal therapy were included. Clinical assessments included mouth opening, cervical mobility, pain intensity, pressure pain thresholds (PPTs), and myofascial trigger points (MTrPs) of the jaw and neck muscles. Results: After the intervention, a significant reduction in mouth opening (41.90 mm; SD = 6.21) was observed compared to baseline (46.28 mm; SD = 6.17) (p < 0.001). A significant reduction in PPTs and cervical mobility (p < 0.05), and an increase in MTrPs (p = 0.002–0.026) were demonstrated after the intervention. Conclusions: A session of root canal therapy can produce an immediate significant reduction in mouth opening, PPTs, and cervical mobility, and an increase in MTrPs. The risk can be higher if there is a previous TMJ limitation.

2 January 2025 in Cranio®
Verified
Journal Article
Closed access
SCSilvia Cardiel-Sánchez
Silvia Cardiel-Sánchez
ARAitziber Rubio-Aramendi
Aitziber Rubio-Aramendi
RVRaquel Vega-Plá
Raquel Vega-Plá
IAIsabel Albarova-Corral
Isabel Albarova-Corral
MMMiguel Malo-Urriés
Miguel Malo-Urriés
To analyse the relationship between bruxism and musculoskeletal parameters of the cervical and mandibular regions in children and adolescents. A comparative cross-sectional study was performed with subjects from 6 to 16 years. Subjects were divided into bruxism (any type) and control groups. Descriptive data, jaw opening, upper cervical spine mobility, myofascial trigger points (MTPs) and muscular tension of the jaw and neck muscles, the activation pattern of neck flexors and activation of Deep Neck Flexors (DNF) were registered and compared between groups. 121 subjects participated in the study. Children and adolescents reporting bruxism showed a significant reduction in the contraction of DNF (p = .034) and the activation ratio (p = .035) compared to controls. Besides, MTPs of both masseters were significantly more frequent in subjects reporting bruxism (p = .001-0.002). No differences were found in other measurements. Bruxism is related to a weaker contraction of DNF, a lower activation ratio, and a higher number of MTPs in masseters.