This paper describes the development of an innovative timber–concrete composite bridge system and especially focuses on the evaluation of the load tests of an experimental bridge structure. The load-bearing structure was designed as glue-laminated timber beams connected with only 60-mm-thick precast bridge deck segments made of ultra-high-performance concrete (UHPC). To verify the production details and behavior of the designed structure, we built a full-scale experimental structure and performed a load test. The load test was arranged as a four-point bending test. First, we performed the overall load test until failure. Some bridge deck segments were consequently cut from the structure in order to run further load tests of the bridge deck in the transversal direction. The results of the experiments were evaluated in detail and compared with analytical calculations.
This paper focuses on the determination of the flexural strength of thin slabs made of the Ultra High Performance Fiber Reinforced Concrete (UHPFRC). The load-bearing capacity in bending of elements reinforced only with steel fibers (used as a scattered reinforcement) is primarily influenced by the orientation and distribution of the fibers. A size-effect occurs by these elements. Some special bending tests were executed within the development of precast bridge deck segments for an innovative timber-concrete composite bridge system. The bending tests were executed on the slab strips under similar boundary conditions as by the bridge deck segments. The slab strips of various thickness of 40, 50, 60, 70 and 80 mm were tested in 4-point bending tests with span 1900 mm and in 3-point bending tests with span 600 mm. Half of the test specimens was tested in casting position, the other half was tested upside down. The obtained values of the flexural strength were compared to values from reference bending tests of the beams 150 x 150 x 700 mm, 100 x 100 x 400 mm and 40 x 40 x 160 mm. An influence of the different size of the tested specimen, of the slab thickness, of the span size and of the positioning of the slab with respect to the direction of casting on the flexural strength are evaluated. The experiments are further supported by numerical simulation.
This paper presents the results of testing and the first application of a newly developed innovative system of the bridge superstructures made of UHPC material. Being designed for footbridges it is called short span footbridge system - SSFS. This system was developed for a wide range of uses mainly as footbridges for pedestrians and cyclists and without waterproofing or surfacing. Prestressed prefabricated elements work as single-span beams with a span of up to 20 meters. Thanks to the optimization of the geometry design and the advantageous use of the mechanical properties of the UHPC material in combination with the prestressing, it was possible to achieve a very small construction height. These subtle and light load-bearing components tend to move away from traditional concrete structures, their span-to-depth ratios are closer to steel beams, but the needs for corrosion protection are eliminated using UHPC, which is inherently very durable and therefore almost maintenance-free. SSFS elements can be manufactured with a variable width of up to approx. 3.2 m, but they can be connected transversely and therefore the width of the structure is not limited. The first part of the paper is devoted to the development of the system and real applications of the first few footbridges made of UHPC material and other possibilities of this technology for future applications. The second part of the paper mentions the design and experimental verification of anchoring devices that are used to manipulate small-span footbridges made of UHPC.
In the first part, this paper presents the experimental development of an innovative medium span footbridge system made of UHPFRC. The load bearing structure is designed as a U-shaped beam and consists of 2 main precast prestressed beams, which are connected with precast bridge deck segments. This system is different from the commonly used segmental footbridge structures because a longitudinal prefabrication is used. The development of this system was initiated for several reasonsno need to assemble a falsework and a formwork in situ, no need for heavy cranes, the main load-bearing structure does not contain transverse joints, a possibility to prestress the structure in advance in factory. In the other part, the article discusses another system of shortspan footbridges made of UHPFRC designed and used in the Czech Republic. These footbridges are in the shape of a slab with ribs, and they are manufactured and placed on the substructure as a whole, so they represent an advantage especially in terms of construction speed and low maintenance requirements.
Reliability assessments of concrete bridges are currently made using valid codes of practice based on the limit state concept. Verification may be carried out using the partial factor format or structural reliability methods. The reliability assessment should be made taking into account the service life of a structure, the selected reference period, and the changes in the environment of the structure and possibly anticipated changes in use. This contribution focuses on the verification of models for thermal actions for concrete bridges. An example of updating the design value and partial factor for thermal actions using site-specific measurements—shade air temperature measurements and on-bridge measurements—is developed. Two probabilistic models are employed to characterise annual extremes of ambient air temperatures and the effect of choice of the distribution on the partial factor for thermal actions is discussed. It appears that on-bridge measurements may significantly improve the model for both uniform temperature and temperature difference components in comparison to the EN 1991-1-5 model, with reduction of the design value up to 30% in the case study. A useful alternative for practical applications is to update thermal action effects using records from the nearest meteorological station (reduction about 20%). Using either meteorological or on-bridge measurements, the partial factor can be decreased to 1.2 for the uniform temperature component and to 1.3 for the difference temperature component. The choice of probabilistic distribution seems to be of low importance for the bridge under consideration. Further research should be mainly focused on investigating the effects of climate change and analysis of thermal action effects on different types of concrete bridges and bridges from other structural materials.