David Citek

Mr. David Citek


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2020 in Materials
Verified
Journal Article
Open access
PDF file
PPPetr Pokorný
Petr Pokorný
JKJiří Kolísko
Jiří Kolísko
DCDavid Citek
David Citek
MKMichaela Kostelecká
Michaela Kostelecká
The study explores the effect of elevated temperatures on the bond strength between prestressing reinforcement and ultra-high performance concrete (UHPC). Laboratory investigations reveal that the changes in bond strength correspond well with the changes in compressive strength of UHPC and their correlation can be mathematically described. Exposition of specimens to temperatures up to 200 °C does not reduce bond strength as a negative effect of increasing temperature is outweighed by the positive effect of thermal increase on the reactivity of silica fume in UHPC mixture. Above 200 °C, bond strength significantly reduces; for instance, a decrease by about 70% is observed at 800 °C. The decreases in compressive and bond strengths for temperatures above 400 °C are related to the changes of phase composition of UHPC matrix (as revealed by X-ray powder diffraction) and the changes in microstructure including the increase of porosity (verified by mercury intrusion porosimetry and observation of confocal microscopy) and development cracks detected by scanning electron microscopy. Future research should investigate the effect of relaxation of prestressing reinforcement with increasing temperature on bond strength reduction by numerical modelling.

11 June 2025 in Engineering Structures
Verified
Journal Article
Closed access
MFMarek Foglar
Marek Foglar
VŠVojtěch Šulc
Vojtěch Šulc
RHRadek Hájek
Radek Hájek
DCDavid Citek
David Citek
AČAdam Čítek
Adam Čítek
JPJiří Pachman
Jiří Pachman

27 April 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
MHMilan Holý
Milan Holý
DCDavid Citek
David Citek
PTPetr Tej
Petr Tej
LVLukáš Vráblík
Lukáš Vráblík
This paper describes the development of an innovative timber–concrete composite bridge system and especially focuses on the evaluation of the load tests of an experimental bridge structure. The load-bearing structure was designed as glue-laminated timber beams connected with only 60-mm-thick precast bridge deck segments made of ultra-high-performance concrete (UHPC). To verify the production details and behavior of the designed structure, we built a full-scale experimental structure and performed a load test. The load test was arranged as a four-point bending test. First, we performed the overall load test until failure. Some bridge deck segments were consequently cut from the structure in order to run further load tests of the bridge deck in the transversal direction. The results of the experiments were evaluated in detail and compared with analytical calculations.

5 November 2019 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
MZMartina Záleská
Martina Záleská
MPMilena Pavlíková
Milena Pavlíková
DCDavid Citek
David Citek
ZPZbyšek Pavlík
Zbyšek Pavlík
The amount of waste tires is still growing worldwide. As landfill is still a significant part of the used tires management, there is a need to look for an environmentally-friendly alternative. This may be the use of waste tire rubber in civil engineering for partial substitution of natural aggregate in concrete production. This paper is focused on the experimental investigation of tire rubber-based aggregate, which was used as a partial replacement of coarse natural aggregate to develop light-weight rubberized concrete with improved thermal insulation properties. First, the assessment of both natural and rubber aggregates was done in terms of their physical and thermal parameters. The basic structural properties, mechanical resistance, and thermal conductivity measurements were conducted for rubber concrete evaluation. The thermal conductivity was studied from the dry to fully water saturated state. The developed rubberized concrete materials showed improved thermal insulation performance, even in the presence of moisture. The mechanical strength of rubberized concretes was mostly sufficient for non-structural applications, such as multi-layered floor structures or wall insulation panels.

10 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
RPRadka Pernicová
Radka Pernicová
DCDavid Citek
David Citek
DDDaniel Dobias
Daniel Dobias
JKJiri Kolisko
Jiri Kolisko
TMTomas Mandlik
Tomas Mandlik
LHLucie Hausmannova
Lucie Hausmannova
This article deals with the development of concretes intended to be used as construction materials in the Czech deep repository for radioactive waste. The basic requirements for this concrete are a reduced pH value, which must maintain a constant reduced pH with a value of around 11 in the long term, and mechanical properties comparable to conventional concrete. The raw materials for the production of the proposed low pH concrete come exclusively from the Czech Republic. Material characteristics were measured on fresh mixtures and concrete after 28, 56, and 90 days of curing. In addition to the basic raw materials (aggregate, cement, water), plasticizers, microsilica or slag, and defoaming agents were added to the mixture. The aggregate:binder ratio was approximately 5:1 and the w/c water coefficient was approximately 0.6. The mechanical properties of the final concrete were similar to the reference recipe of conventional concrete (the decrease was less than 10%) and the pH value was even below 11 after 90 days. The issue of a sprayed variant of the LPC mixture was solved within the project.

25 October 2024 in Emergent Materials
Verified
Journal Article
Open access
PDF file
NKNela Krčmářová
Nela Krčmářová
JSJan Sleichrt
Jan Sleichrt
JFJan Falta
Jan Falta
PKPetr Koudelka
Petr Koudelka
Daniel KytyrDaniel Kytyr
Daniel Kytyr
Tomas FilaTomas Fila
Tomas Fila
Excellent mechanical properties of ultra high performance concrete make it suitable for use in special applications, where the material is subjected to dynamic phenomena such as impacts, explosions, or earthquakes. This paper presents a novel experimental approach that integrates a Split Hopkinson Pressure Bar with a flash X-ray system and high-speed optical imaging to investigate the dynamic behavior of steel fiber reinforced UHPC under high strain rate uni-axial compression. In-situ Flash X-ray radiography emerges as a particularly effective tool, providing clear visualization of deformation response and overcoming challenges associated with flying debris encountered in optical inspection. Moreover, computed tomography and scanning electron microscopy appear as a vital technique for analyzing micro-structure and fiber distribution and orientation. The combined approach offers a promising method to study the dynamic behavior of steel fiber reinforced ultra high performance concrete and also holds promise for analyzing more complex modes of deformation and material interactions, providing valuable insights for enhancing the design and performance of critical infrastructure subjected to dynamic loading events.