Aleksandar Janjic

Aleksandar Janjic


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
AJAleksandar Janjic
Aleksandar Janjic
MCMehmet Cayoren
Mehmet Cayoren
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Emre OnemliEmre Onemli
Emre Onemli
MAMustafa Erkin Aribal
Mustafa Erkin Aribal
SAFE (Scan and Find Early) is a novel microwave imaging device intended for breast cancer screening and early detection. SAFE is based on the use of harmless electromagnetic waves and can provide relevant initial diagnostic information without resorting to X-rays. Because of SAFE’s harmless effect on organic tissue, imaging can be performed repeatedly. In addition, the scanning process itself is not painful since breast compression is not required. Because of the absence of physical compression, SAFE can also detect tumors that are close to the thoracic wall. A total number of 115 patients underwent the SAFE scanning procedure, and the resultant images were compared with available magnetic resonance (MR), ultrasound, and mammography images in order to determine the correct detection rate. A sensitivity of 63% was achieved. Breast size influenced overall sensitivity, as sensitivity was lower in smaller breasts (51%) compared to larger ones (74%). Even though this is only a preliminary study, the results show promising concordance with clinical reports, thus encouraging further SAFE clinical studies.

10 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gulsah YildizGulsah Yildiz
Gulsah Yildiz
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
AJAleksandar Janjic
Aleksandar Janjic
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Microwave hyperthermia (MH) requires the selective focusing of microwave energy on the targeted region while minimally affecting the healthy tissue. Emerging from the simple nature of the linear antenna arrays, this work demonstrates focusing maps as an application guide for MH focusing by adjusting the antenna phase values. The focusing of the heating potential (HP) on different density breast models is performed via the proposed method using Vivaldi antennas. The effect of the tumor conductivity on the focusing is discussed. As a straightforward approach and utilizing the Vivaldi antennas, the system can be further combined with MH monitoring application.