Tuba Yilmaz Yilmaz

Dr. Tuba Yilmaz Yilmaz

Department of Electronics and Communıcation Engineering, Istanbul Technical University, Istanbul 34469, Turkey
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2019 in Diagnostics
Verified
Journal Article
Open access
PDF file
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
RFRobert Foster
Robert Foster
YHYang Hao
Yang Hao
This paper reviews non-invasive blood glucose measurements via dielectric spectroscopy at microwave frequencies presented in the literature. The intent is to clarify the key challenges that must be overcome if this approach is to work, to suggest some possible ways towards addressing these challenges and to contribute towards prevention of unnecessary ‘reinvention of the wheel’.

16 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
AJAleksandar Janjic
Aleksandar Janjic
MCMehmet Cayoren
Mehmet Cayoren
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Emre OnemliEmre Onemli
Emre Onemli
MAMustafa Erkin Aribal
Mustafa Erkin Aribal
SAFE (Scan and Find Early) is a novel microwave imaging device intended for breast cancer screening and early detection. SAFE is based on the use of harmless electromagnetic waves and can provide relevant initial diagnostic information without resorting to X-rays. Because of SAFE’s harmless effect on organic tissue, imaging can be performed repeatedly. In addition, the scanning process itself is not painful since breast compression is not required. Because of the absence of physical compression, SAFE can also detect tumors that are close to the thoracic wall. A total number of 115 patients underwent the SAFE scanning procedure, and the resultant images were compared with available magnetic resonance (MR), ultrasound, and mammography images in order to determine the correct detection rate. A sensitivity of 63% was achieved. Breast size influenced overall sensitivity, as sensitivity was lower in smaller breasts (51%) compared to larger ones (74%). Even though this is only a preliminary study, the results show promising concordance with clinical reports, thus encouraging further SAFE clinical studies.

1 September 2019 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
BSBanu Saçlı
Banu Saçlı
CACemanur Aydınalp
Cemanur Aydınalp
GCGökhan Cansız
Gökhan Cansız
SJSULAYMAN JOOF
SULAYMAN JOOF
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
IAIbrahim Akduman
Ibrahim Akduman

31 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
IDIsmail Dilman
Ismail Dilman
MAMehmet Nuri Akinci
Mehmet Nuri Akinci
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
MCMehmet Cayoren
Mehmet Cayoren
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
This work presents a new method to measure the complex dielectric permittivity (CDP) variation of materials under test (MUTs) with open-ended coaxial probes. The CDP variation of an MUT is a continuous function of frequency as modeled with various dielectric relaxation models. Hence, the accuracy and the repeatability of CDP measurements can be improved by enforcing such spectral continuity. Here, we derive a new formulation that explicitly enforces the spectral continuity via the Debye relaxation model. In particular, we construct a cost functional based on an admittance integral at the tip of an open-ended coaxial probe. The Debye model parameters are substituted into the admittance integral to form a set of nonlinear equations. Later, these equations are iteratively minimized by a Gauss–Newton-based minimization scheme, for measured reflection coefficients when the tip of the probe is in contact with the MUT. The presented method differs from the conventional CDP measurement techniques in two aspects. First, the method looks for a global solution across the investigated frequency spectrum instead of solving CDP values individually at each frequency step. Second, the Debye parameters are directly retrieved without any data-fitting. The presented method is experimentally verified with various liquid samples, and the accuracy of obtained results is compared against the literature.

19 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CACemanur Aydinalp
Cemanur Aydinalp
SJSULAYMAN JOOF
SULAYMAN JOOF
IDIsmail Dilman
Ismail Dilman
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
The open-ended coaxial probe (OECP) method is frequently used for the microwave dielectric property (DP) characterization of high permittivity and conductivity materials due to inherent advantages including minimal sample preparation requirements and broadband measurement capabilities. However, the OECP method is known to suffer from high measurement error. One well-known contributor to the high error rates is tissue heterogeneity, which can potentially be managed through the selection of a probe with a proper sensing depth (SD). The SD of the OECP is dependent on many factors including sample DPs and probe aperture diameter. Although the effects of sample DPs on SD have been investigated to some extent in the literature, the probe aperture diameters, particularly small diameters, have not been fully explored. To this end, the SDs of probes with three different apertures (0.5, 0.9 and 2.2 mm-diameters) were analyzed in this study. Probes’ SDs were first investigated with simulations using a double-layered sample configuration (skin tissue and olive oil). Next, experiments were performed using a commercial OECP with a 2.2 mm aperture diameter. The SD was categorized based on 5%, 20% and 80% DP change. Among these threshold values, a 5% DP change was selected as the benchmark for SD categorization. The findings suggest that probes with a smaller aperture size and correspondingly smaller SD should be utilized when measuring the DPs of thin and multilayered samples, such as healthy and diseased skin tissues, to increase the measurement accuracy.

10 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gulsah YildizGulsah Yildiz
Gulsah Yildiz
Ibrahim AkdumanIbrahim Akduman
Ibrahim Akduman
AJAleksandar Janjic
Aleksandar Janjic
Tuba Yilmaz YilmazTuba Yilmaz Yilmaz
Tuba Yilmaz Yilmaz
Microwave hyperthermia (MH) requires the selective focusing of microwave energy on the targeted region while minimally affecting the healthy tissue. Emerging from the simple nature of the linear antenna arrays, this work demonstrates focusing maps as an application guide for MH focusing by adjusting the antenna phase values. The focusing of the heating potential (HP) on different density breast models is performed via the proposed method using Vivaldi antennas. The effect of the tumor conductivity on the focusing is discussed. As a straightforward approach and utilizing the Vivaldi antennas, the system can be further combined with MH monitoring application.