SAFE (Scan and Find Early) is a novel microwave imaging device intended for breast cancer screening and early detection. SAFE is based on the use of harmless electromagnetic waves and can provide relevant initial diagnostic information without resorting to X-rays. Because of SAFE’s harmless effect on organic tissue, imaging can be performed repeatedly. In addition, the scanning process itself is not painful since breast compression is not required. Because of the absence of physical compression, SAFE can also detect tumors that are close to the thoracic wall. A total number of 115 patients underwent the SAFE scanning procedure, and the resultant images were compared with available magnetic resonance (MR), ultrasound, and mammography images in order to determine the correct detection rate. A sensitivity of 63% was achieved. Breast size influenced overall sensitivity, as sensitivity was lower in smaller breasts (51%) compared to larger ones (74%). Even though this is only a preliminary study, the results show promising concordance with clinical reports, thus encouraging further SAFE clinical studies.
31 January 2022 in IEEE Transactions on Instrumentation and Measurement
This work presents a new method to measure the complex dielectric permittivity (CDP) variation of materials under test (MUTs) with open-ended coaxial probes. The CDP variation of an MUT is a continuous function of frequency as modeled with various dielectric relaxation models. Hence, the accuracy and the repeatability of CDP measurements can be improved by enforcing such spectral continuity. Here, we derive a new formulation that explicitly enforces the spectral continuity via the Debye relaxation model. In particular, we construct a cost functional based on an admittance integral at the tip of an open-ended coaxial probe. The Debye model parameters are substituted into the admittance integral to form a set of nonlinear equations. Later, these equations are iteratively minimized by a Gauss–Newton-based minimization scheme, for measured reflection coefficients when the tip of the probe is in contact with the MUT. The presented method differs from the conventional CDP measurement techniques in two aspects. First, the method looks for a global solution across the investigated frequency spectrum instead of solving CDP values individually at each frequency step. Second, the Debye parameters are directly retrieved without any data-fitting. The presented method is experimentally verified with various liquid samples, and the accuracy of obtained results is compared against the literature.
The open-ended coaxial probe (OECP) method is frequently used for the microwave dielectric property (DP) characterization of high permittivity and conductivity materials due to inherent advantages including minimal sample preparation requirements and broadband measurement capabilities. However, the OECP method is known to suffer from high measurement error. One well-known contributor to the high error rates is tissue heterogeneity, which can potentially be managed through the selection of a probe with a proper sensing depth (SD). The SD of the OECP is dependent on many factors including sample DPs and probe aperture diameter. Although the effects of sample DPs on SD have been investigated to some extent in the literature, the probe aperture diameters, particularly small diameters, have not been fully explored. To this end, the SDs of probes with three different apertures (0.5, 0.9 and 2.2 mm-diameters) were analyzed in this study. Probes’ SDs were first investigated with simulations using a double-layered sample configuration (skin tissue and olive oil). Next, experiments were performed using a commercial OECP with a 2.2 mm aperture diameter. The SD was categorized based on 5%, 20% and 80% DP change. Among these threshold values, a 5% DP change was selected as the benchmark for SD categorization. The findings suggest that probes with a smaller aperture size and correspondingly smaller SD should be utilized when measuring the DPs of thin and multilayered samples, such as healthy and diseased skin tissues, to increase the measurement accuracy.
Microwave hyperthermia (MH) requires the selective focusing of microwave energy on the targeted region while minimally affecting the healthy tissue. Emerging from the simple nature of the linear antenna arrays, this work demonstrates focusing maps as an application guide for MH focusing by adjusting the antenna phase values. The focusing of the heating potential (HP) on different density breast models is performed via the proposed method using Vivaldi antennas. The effect of the tumor conductivity on the focusing is discussed. As a straightforward approach and utilizing the Vivaldi antennas, the system can be further combined with MH monitoring application.
20 October 2014 in IEEE Transactions on Biomedical Engineering
In this paper we present an effective method for developing realistic numerical three-dimensional (3-D) microwave breast models of different shape, size, and tissue density. These models are especially convenient for microwave breast cancer imaging applications and numerical analysis of human breast-microwave interactions. As in the recent studies on this area, anatomical information of the breast tissue is collected from T1-weighted 3-D MRI data of different patients' in prone position. The method presented in this paper offers significant improvements including efficient noise reduction and tissue segmentation, nonlinear mapping of electromagnetic properties, realistically asymmetric phantom shape, and a realistic classification of breast phantoms. Our method contains a five-step approach where each MRI voxel is classified and mapped to the appropriate dielectric properties. In the first step, the MRI data are denoised by estimating and removing the bias field from each slice, after which the voxels are segmented into two main tissues as fibro-glandular and adipose. Using the distribution of the voxel intensities in MRI histogram, two nonlinear mapping functions are generated for dielectric permittivity and conductivity profiles, which allow each MRI voxel to map to its proper dielectric properties. Obtained dielectric profiles are then converted into 3-D numerical breast phantoms using several image processing techniques, including morphologic operations, filtering. Resultant phantoms are classified according to their adipose content, which is a critical parameter that affects penetration depth during microwave breast imaging.
6 October 2022 in IEEE Transactions on Microwave Theory and Techniques
In this work, we proposed a general guideline and a technique for retrieving the complex permittivities (CPs) of material under test (MUT) from the measured reflection coefficients (RCs) obtained with the openended coaxial probe (OECP) through a deep learning model (DLM). Particularly, lossy materials such as phantoms mimicking the biological tissues are considered as MUT in this study. The dataset used to design (train, validate, and test) the DLM is synthetically generated using the relationship between the CPs of the MUT, namely, admittance model, and the fourpole Cole–Cole relaxation model. Moreover, the technique is implemented to accurately predict the CPs of biological tissues with real measured RCs’ data from 0.5 to 20 GHz with a 50-MHz resolution. This technique eliminates the need to physically perform measurements required to create the dataset for DLM and it can be easily implemented for realtime CPs’ measurement of biological tissues. The designed DLM is initially trained, validated, and tested with 80%, 10%, and 10% of the total generated synthetic dataset, respectively. A percent relative error of 1.5 $\pm$ 0.88% is obtained for CPs’ prediction at the test stage. Furthermore, DLM is tested with real RCs’ data measured from four different tissuemimicking phantoms: skin, muscle, blood, and fat. Predicted CPs from DLM are compared with the CPs’ results obtained from a commercially available OECP measurement kit. A (mean) $\pm$ (std.dev) percent relative error ranging from 2.08 $\pm$ 0.4 to 10.84 $\pm$ 2.43 within the frequency band of interest was obtained after comparison.