Sagar Wadhwa

Mr. Sagar Wadhwa

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
Emil R. MamleyevEmil R. Mamleyev
Emil R. Mamleyev
FFFabian Falk
Fabian Falk
PWPeter G. Weidler
Peter G. Weidler
SHStefan Heissler
Stefan Heissler
SWSagar Wadhwa
Sagar Wadhwa
JKJan Korvink
Jan Korvink
A method for the fabrication of flexible electrical circuits on polyaramid substrates is presented based on laser-induced carbonization followed by copper electroplating. Locally carbonized flexible sheets of polyaramid (Nomex), by laser radiation, create rough and highly porous microstructures that show a higher degree of graphitization than thermally carbonized Nomex sheets. The found recipe for laser-induced carbonization creates conductivities of up to ∼45 S cm–1, thereby exceeding that observed for thermally pyrolyzed materials (∼38 S cm–1) and laser carbon derived from Kapton using the same laser wavelength (∼35 S cm–1). The electrical conductivity of the carbonized tracks was further improved by electroplating with copper. To demonstrate the electrical performance, fabricated circuits were tested and improvement of the sheet resistance was determined. Copper films exhibit antimicrobial activity and were used to fabricate customized flexible antibacterial coatings. The integration of laser carbonization and electroplating technologies in a polyaramid substrate points to the development of customized circuit designs for smart textiles operating in high-temperature environments.

23 August 2024 in Advanced Materials
Verified
Journal Article
Open access
SWSagar Wadhwa
Sagar Wadhwa
DBDominique Buyens
Dominique Buyens
JKJan Korvink
Jan Korvink
Unaided nuclear magnetic resonance (NMR) spectroscopy is considered incapable of distinguishing enantiomers. However, as first derived by A.D. Buckingham, the tensor coupling the electric and magnetic dipoles is space‐dependent, which varies according to the molecular structure, hence, would be different for two enantiomers. Exploiting the odd‐parity coupling tensor, a new variant of a double‐resonant radiofrequency (RF) NMR detector is developed, which is sensitive to both electric and magnetic dipoles. Using the detector, a new method for liquid‐state NMR is developed and elaborated, with which two enantiomers are successfully discriminated.

1 October 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
ONOmar Nassar
Omar Nassar
MMMarkus V. Meissner
Markus V. Meissner
SWSagar Wadhwa
Sagar Wadhwa
JKJan Korvink
Jan Korvink
DMDario Mager
Dario Mager
Electrodeposition is a highly versatile and well explored technology. However, it also depends strongly on the experience level of the operator. This experience includes the pretreatment of the sample, and the composition of the electrolyte settings of the plating parameters. Accurate control over the electroplating current is needed especially for the formation of small structures, where pulsed electrodeposition has proven to reduce many unwanted effects. To bring precision into the formation of optimal recipes, a highly flexible current source based on a microcontroller was developed. It allows a large variety of pulse waveforms, as well as maintaining a feedback loop that controls the current and monitors the output voltage, allowing for both galvanostatic (current driven) and potentiostatic (voltage driven) electrodeposition. The system has been implemented with multiple channels, permitting the simultaneous electrodeposition of multiple substrates in parallel. Being based on a microcomputer, the system can be programmed using predefined recipes individually for each channel, or even adapt the recipes during plating. All measurement values are continuously recorded for the purpose of documentation and diagnosis. The current source is based on a high power operational amplifier in a modified Howland current source configuration. This paper describes the functionality of the electrodeposition system, with a focus on the stability of the source current under different electrodeposition current densities and frequencies. The performance and high capability of the system is demonstrated by performing and analyzing two nontrivial plating applications.

20 November 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
VVVitor Vlnieska
Vitor Vlnieska
AVAchim Voigt
Achim Voigt
SWSagar Wadhwa
Sagar Wadhwa
JKJan Korvink
Jan Korvink
Manfred KohlManfred Kohl
Manfred Kohl
Kirill PoletkinKirill Poletkin
Kirill Poletkin
A control circuit for inductive levitation micro-actuators was developed in this research, the circuit’s performance and its electrical parameters are discussed. The developed control circuit was fabricated on a four-layer printed circuit board (PCB) board with a size of 60 × 60 × 25 mm. It consisted of a generator based on high-speed Flip-Flop components and a current amplifier build on a H-bridge configuration. The circuit was able to generate an AC current with a squared waveform in a frequency range from 8 to 43 MHz and with a peak-to-peak amplitude of up to 420 mA. To demonstrate the efficiency of developed circuit and its compatibility with a micro-actuation system, an inductive levitation micro-actuator was fabricated by using 3D micro-coil technology. The device was composed of two solenoidal coil designs, a levitation and a stabilization coil, with outer diameters of 2 and 3.8 mm, respectively. A 25 μm diameter gold wire was used to fabricate the coils, with the levitation coil having 20 turns and the stabilization coil having 12 turns, similar to the micro-structure presented previously by our group. Using the developed control circuit, the micro-actuator was successfully excited and it demonstrated the actuation of aluminum disc-shaped micro-objects with diameters of 2.8 and 3.2 mm and, for the first time, an aluminum square-shaped object with a side length of 2.8 mm at a frequency of 10 MHz. To characterize the actuation, the levitation height and the current amplitude were measured. In particular, we demonstrated that the square-shaped micro-object could be lifted up to a height of 84 μm with a current of 160 mA. The characterization was supported by a simulation using a 3D model based on the quasi-finite element model (FEM) approach.

12 October 2020 in Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SWSagar Wadhwa
Sagar Wadhwa
MJMazin Jouda
Mazin Jouda
YDYongbo Deng
Yongbo Deng
ONOmar Nassar
Omar Nassar
Dario MagerDario Mager
Dario Mager
JKJan Korvink
Jan Korvink
Improvements to the signal-to-noise ratio of magnetic resonance detection lead to a strong reduction in measurement time, yet as a sole optimization goal for resonator design, it would be an oversimplification of the problem at hand. Multiple constraints, for example for field homogeneity and sample shape, suggest the use of numerical optimization to obtain resonator designs that deliver the intended improvement. Here we consider the 2D Lenz lens to be a sufficiently broadband flux transforming interposer between the sample and a radiofrequency (RF) circuit and to be a flexible and easily manufacturable device family with which to mediate different design requirements. We report on a method to apply topology optimization to determine the optimal layout of a Lenz lens and demonstrate realizations for both low- (45 MHz) and high-frequency (500 MHz) nuclear magnetic resonance.

1 August 2026 in Review of Scientific Instruments
Verified
Journal Article
Open access
SDSebastiaan Van Dyck
Sebastiaan Van Dyck
CWColine Wiame
Coline Wiame
HLHadi Loutfi
Hadi Loutfi
ASAnna Sonnefeld
Anna Sonnefeld
PPPhilippe Pelupessy
Philippe Pelupessy
BGBodenhausen Geoffrey
Bodenhausen Geoffrey
A quadruple probe was designed for wide-bore spectrometers with four independent detectors, with sample volumes of ∼5 μl each. Four transmission-line detectors are equipped with radio frequency channels for 1H (or 19F) and 13C, which can be tuned and matched independently. Each detector is equipped with 6 on-chip shim-coils for local shimming. Linear pulsed field gradients can be applied independently to each sample along the z-axis (in the B0 direction). Slice selection allows one to reduce the effective volumes to ∼2.5 μl to improve the resolution and minimize crosstalk. Four sets of experiments can be acquired simultaneously on four different samples, for example, four inversion-recovery or four Carr–Purcell–Meiboom–Gill experiments.