Omar Nassar

Omar Nassar

Auto-generated profile, based on publicly available information

Omar Nassar

Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
Emil R. MamleyevEmil R. Mamleyev
Emil R. Mamleyev
FFFabian Falk
Fabian Falk
PWPeter G. Weidler
Peter G. Weidler
SHStefan Heissler
Stefan Heissler
SWSagar Wadhwa
Sagar Wadhwa
JKJan Korvink
Jan Korvink
A method for the fabrication of flexible electrical circuits on polyaramid substrates is presented based on laser-induced carbonization followed by copper electroplating. Locally carbonized flexible sheets of polyaramid (Nomex), by laser radiation, create rough and highly porous microstructures that show a higher degree of graphitization than thermally carbonized Nomex sheets. The found recipe for laser-induced carbonization creates conductivities of up to ∼45 S cm–1, thereby exceeding that observed for thermally pyrolyzed materials (∼38 S cm–1) and laser carbon derived from Kapton using the same laser wavelength (∼35 S cm–1). The electrical conductivity of the carbonized tracks was further improved by electroplating with copper. To demonstrate the electrical performance, fabricated circuits were tested and improvement of the sheet resistance was determined. Copper films exhibit antimicrobial activity and were used to fabricate customized flexible antibacterial coatings. The integration of laser carbonization and electroplating technologies in a polyaramid substrate points to the development of customized circuit designs for smart textiles operating in high-temperature environments.

14 April 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
ONOmar Nassar
Omar Nassar
MJMazin Jouda
Mazin Jouda
MRMichael Rapp
Michael Rapp
Dario MagerDario Mager
Dario Mager
JKJan Korvink
Jan Korvink
NMNeil MacKinnon
Neil MacKinnon
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample plugs separated by an immiscible fluid. This dual-phase flow demands a real-time robust sensing system to track the sample position and velocities and synchronize the NMR acquisition. In this contribution, we describe an NMR probe head that possesses a microfluidic system featuring: (i) a micro saddle coil for NMR spectroscopy and (ii) a pair of interdigitated capacitive sensors flanking the NMR detector for continuous position and velocity monitoring of the plugs with respect to the NMR detector. The system was successfully tested for automating flow-based measurement in a 500 MHz NMR system, enabling high resolution spectroscopy and NMR sensitivity of 2.18 nmol s1/2 with the flow sensors in operation. The flow sensors featured sensitivity to an absolute difference of 0.2 in relative permittivity, enabling distinction between most common solvents. It was demonstrated that a fully automated NMR measurement of nine individual 120 μL samples could be done within 3.6 min or effectively 15.3 s per sample.

16 March 2023 in Biosensors and Bioelectronics: X
Verified
Journal Article
Open access
LJLourdes Albina Nirupa Julius
Lourdes Albina Nirupa Julius
HSHenrik Scheidt
Henrik Scheidt
GKGowri Krishnan
Gowri Krishnan
MBMoritz Becker
Moritz Becker
ONOmar Nassar
Omar Nassar
JKJan Korvink
Jan Korvink

8 September 2022 in Small
Verified
Journal Article
Open access
BMBeibei Meng
Beibei Meng
SGStephan L Grage
Stephan L Grage
OBOleg Babii
Oleg Babii
MTMasanari Takamiya
Masanari Takamiya
NMNeil MacKinnon
Neil MacKinnon
AUAnne S Ulrich
Anne S Ulrich
A labeling strategy for in vivo 19F‐MRI (magnetic resonance imaging) based on highly fluorinated, short hydrophilic peptide probes, is developed. As dual‐purpose probes, they are functionalized further by a fluorophore and an alkyne moiety for bioconjugation. High fluorination is achieved by three perfluoro‐tert‐butyl groups, introduced into asparagine analogues by chemically stable amide bond linkages. d‐amino acids and β‐alanine in the sequences endow the peptide probes with low cytotoxicity and high serum stability. This design also yielded unstructured peptides, rendering all 27 19F substitutions chemically equivalent, giving rise to a single 19F‐NMR resonance with <10 Hz linewidth. The resulting performance in 19F‐MRI is demonstrated for six different peptide probes. Using fluorescence microscopy, these probes are found to exhibit high stability and long circulation times in living zebrafish embryos. Furthermore, the probes can be conjugated to bovine serum albumin with only amoderate increase in 19F‐NMR linewidth to ≈30 Hz. Overall, these peptide probes are hence suitable for in vivo 19F‐MRI applications.

1 October 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
ONOmar Nassar
Omar Nassar
MMMarkus V. Meissner
Markus V. Meissner
SWSagar Wadhwa
Sagar Wadhwa
JKJan Korvink
Jan Korvink
DMDario Mager
Dario Mager
Electrodeposition is a highly versatile and well explored technology. However, it also depends strongly on the experience level of the operator. This experience includes the pretreatment of the sample, and the composition of the electrolyte settings of the plating parameters. Accurate control over the electroplating current is needed especially for the formation of small structures, where pulsed electrodeposition has proven to reduce many unwanted effects. To bring precision into the formation of optimal recipes, a highly flexible current source based on a microcontroller was developed. It allows a large variety of pulse waveforms, as well as maintaining a feedback loop that controls the current and monitors the output voltage, allowing for both galvanostatic (current driven) and potentiostatic (voltage driven) electrodeposition. The system has been implemented with multiple channels, permitting the simultaneous electrodeposition of multiple substrates in parallel. Being based on a microcomputer, the system can be programmed using predefined recipes individually for each channel, or even adapt the recipes during plating. All measurement values are continuously recorded for the purpose of documentation and diagnosis. The current source is based on a high power operational amplifier in a modified Howland current source configuration. This paper describes the functionality of the electrodeposition system, with a focus on the stability of the source current under different electrodeposition current densities and frequencies. The performance and high capability of the system is demonstrated by performing and analyzing two nontrivial plating applications.

12 September 2017 in Procedia Engineering
Verified
Journal Article
Open access
Peter IbrahimPeter Ibrahim
Peter Ibrahim
ONOmar Nassar
Omar Nassar
MAMustafa Arafa
Mustafa Arafa
Yasser AnisYasser Anis
Yasser Anis
Inertial vibration energy harvesters are effective only when they operate at their natural frequencies. A slight deviation from operation at resonance conditions leads to a substantial reduction in the generated power, which places hurdles for the development of devices that operate across a wide frequency range. To address this issue, we present a vibration energy harvester with a tunable natural frequency. Frequency adjustment in a cantilever-type energy harvester is achieved by varying the rotary inertia of the beam through changing the angular position of a rotatable mass mounted at its tip. The mass is driven by a beam-mounted servomotor which controls its angular position about an axis normal to the beam’s mid-plane, thereby varying the effective mass moment of inertia. In this arrangement, the power required for frequency adjustment is kept to a minimum, since no mechanical straining forces are applied on the beam, and power is only needed when the motor turns to adjust the orientation of the tuning mass. A frequency tuning algorithm is developed to keep the beam operating at resonance. The algorithm relies on information gathered by an infrared sensor/receiver module that detects the prevailing frequency of vibration by a microprocessor and drives the servomotor in accordance with a lookup table that relates natural frequency with angular position of the motor. An analytical model is developed to predict the system dynamics and the variation in natural frequency in terms of the various design parameters. While the proposed design is applicable to various types of vibration energy harvesters, an electromagnetic prototype is presented to verify the concept. Findings of the theoretical model are verified experimentally.