Suresh Y

Dr. Suresh Y

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HAHadik Azeem
Hadik Azeem
SYSuresh Y
Suresh Y
VJVenkataramanaiah Jammala
Venkataramanaiah Jammala
BNBanavath Shiva Naik
Banavath Shiva Naik
APAnup Kumar Panda
Anup Kumar Panda
In this paper, a unusual switching technique is implemented using a fuzzy logic approach. The proposed technique simplifies the conventional method by eliminating the traditional logic gate design. The fuzzy logic pulse generator acts as a look-up table as well as a pulse generator. Based on the modulation index as input, controlled membership functions (MFs) and rules of the fuzzy logic controller (FLC) opens various possibilities in producing pulses directly. The proposed technique is evaluated on the cascaded multilevel inverter with symmetric and asymmetric operations using selective harmonic elimination pulse width modulation (SHE-PWM). MFs are designed based on the pre-calculated firing conditions for different modulation index values. The hardware verification is carried out to support the proposed switching technique.

5 February 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
VJVenkataramanaiah Jammala
Venkataramanaiah Jammala
SYSuresh Y
Suresh Y
APAnup Kumar Panda
Anup Kumar Panda
This letter presents a single phase cascaded transformer multilevel inverter with modified carrier based level shift sinusoidal pulse width modulation (LS-SPWM) technique. The developed topology has two bridges with individual low frequency transformers. The bridges can generate quasi-square waveform and pulse width modulated (PWM) waveform independently and energized the two transformers whose secondary terminals are cascaded to attain nineteen level output voltage waveform across the load. The anticipated configuration has the least number of components to reduce the cost and enhance the reliability of the converter for medium power applications with inbuilt isolation. Furthermore, this paper presents the most common LS-SPWM technique with a new carrier to enhance the fundamental magnitude and shifts the dominant harmonics into three times of the traditional strategy for the same modulation indices. The performance of the proposed topology is validated with experimental results.

29 May 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
BNBanavath Shiva Naik
Banavath Shiva Naik
SYSuresh Y
Suresh Y
JVJ. Venkataramanaiah
J. Venkataramanaiah
APAnup Kumar Panda
Anup Kumar Panda
Nowadays, output voltage boosting gain property along with curtailment in the circuit voltage stress, and component count are considered as the essential topological features for the new multilevel inverter (MLI) circuits. Recognizing the above, a hybrid nine-level inverter topology (HNIT) for DC-AC conversion is proposed in this work. Each phase of the HNIT is designed with only eight semiconductor switches, one diode, and two electrolytic capacitors. Herein, series-parallel and conventional-series techniques are utilized effectively to balance the capacitor voltages. Further, cost and quantitative comparisons are carried among the state-of-art circuits to highlight the supremacy of proposed circuit. Subsequently, the performance of HNIT is verified experimentally with the fundamental switching PWM technique at different load conditions.

22 November 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JVJ. Venkataramanaiah
J. Venkataramanaiah
SYSuresh Y
Suresh Y
APAnup Kumar Panda
Anup Kumar Panda
This paper presents a single phase 19-level inverter with less number of switching components, leading to reduce the cost and enhance reliability for renewable applications. The anticipated multilevel inverter has two bridges generate quasi-square and seven level uneven waveforms with an equal magnitude steps. Two voltage waveforms are cascaded at secondary side of transformers to create nineteen level output voltage waveform. Further, to find the appropriate switching instants of the proposed configuration, a new fundamental switching method named as fundamental sine quantized switching technique (FSQST) is presented. In fact, it has the capacity to provide N number of switching instants with less computational efforts, and attains optimized Total Harmonic Distortion (THD) in the output voltage. Finally, performance of the proposed topology is validated with simulations and hardware setup.

1 December 2021 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
PDF file
BRBhukya Nageswar Rao
Bhukya Nageswar Rao
SYSuresh Y
Suresh Y
BNBanavath Shiva Naik
Banavath Shiva Naik
JVJammala Venkataramanaiah
Jammala Venkataramanaiah
KAKancharapu Aditya
Kancharapu Aditya
APAnup Kumar Panda
Anup Kumar Panda

5 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
SASachin Angadi
Sachin Angadi
UYUdaykumar R. Yaragatti
Udaykumar R. Yaragatti
SYSuresh Y
Suresh Y
ARA. B. Raju
A. B. Raju
Maximum power point tracking (MPPT) algorithms are invariably employed to utilize solar photovoltaic (PV) systems effectively. Perturbation based MPPT algorithms are popular due to their simplicity and reasonable efficiency. While novel MPPT algorithms claim increased energy utilization over classic perturbation techniques, their performance is governed by the choice of optimal algorithm parameters. Existing guidelines for parameter optimization are mathematically laborious and are not generic. Hence, this paper aims to provide simple and comprehensive guidelines to ensure optimal performance from the perturbation based MPPT technique. For an illustration of proposed claims, a solar PV fed boost converter is investigated to examine the effect of input capacitor, digital filter cut-off frequency, system time constant and sampling time on implementing a classic Perturb and Observe (P and O) algorithm. The readers will be presented with two simple step tests (to determine the effective system time constant) and proposed guidelines to choose the optimal performance sampling time. Necessary laboratory experiments show that an appropriate choice of sampling time could increase efficiency and ensure system stability. This investigation’s learnings can be easily extended to any power electronics converter, loads and all perturbation-based algorithms used in solar PV systems. The results of appropriate tests on the system’s mathematical model and the laboratory prototype are presented in detail to support this research’s claims.