The growth of the construction industry has led to the greater consumption of natural resources, which has a direct or indirect negative impact on the environment. To mitigate this, recycled or waste materials are being used as a partial substitute in the manufacture of concrete. Among these waste materials is cement kiln dust (CKD), which is produced during cement production. This study investigated the potential benefits of replacing part of the cement with CKD in two construction applications, i.e., plain concrete and cement blocks. This reflects positively on cost, energy, and the environment, since putting CKD in a landfill damages agricultural soil and plant respiration. In this study, an experimental program was carried out to study how replacing various percentages of ordinary portland cement (OPC) with CKD affected the compressive strengths, the tensile strengths, and the air contents of concrete and cement blocks. Although the results showed that the compressive and tensile strengths decreased as the amount of CKD increased, the air content of the concrete increased, which showed that 5% CKD was suitable for such applications. The results were used to propose two equations that approximate the concrete and cement block compressive strengths according to the CKD replacement percentage.
In this paper, the recycled fine aggregates and powders produced from crushing old basaltic concrete and natural basalt were used to produce new concrete. The sand was partially replaced by two types of recycled wastes at five percentages: 0%, 20%, 40%, 60%, and 80%. The cement was partially replaced by recycled powders and silica fume (SF) at four percentages: 0, 5%, 10%, and 20%. The concrete strengths and water absorption were obtained at several curing ages. The obtained results emphasized the positive effects of increasing the curing time on enhancing the concrete properties, regardless of the types or the waste sources. Moreover, the recycled powders retarded the hydration reaction. In addition, the recycled fine aggregates and powders could achieve about 99.5% and 99.3% of the ordinary concrete strength and enhance the tensile strength. Furthermore, the mix containing 40% of recycled fine concrete aggregate diffused the highest contents of both calcium and silicate, which led to enhancing the interfacial transition zone (ITZ) and concrete properties, compared to the other tested mixes. Finally, the water absorption of all tested concrete mixes decreased with an increase in the curing age, while the mixes integrating 10% and 20% of SF experienced the lowest values of water absorption.
Literature of Steel Beams with a thin-walled trapezoidal Corrugated Web (SBCWs) shows that the capacity of SBCWs is affected by both the fatigue cracks initiated along the inclined folds (IFs) and the maximal additional stress located in the middle of the IFs. An experimental investigation on the behaviour of hybrid SBCWs under flexure is presented in this paper. This study focuses on the effect of the welding IF between the web and flanges (IFs welded or non-welded), the horizontal-fold length (200, 260, and 350 mm), and transversal flange stiffeners on the failure mechanism of the SBCW under three line load. Accordingly, six hybrid specimens were fabricated, instrumented, and tested (five SBCW specimens and one specimen with a flat web). The test setup was designed to generate shear and a moment in the testing zone via three-point bending. The results indicated that non-welded IFs specimens with or without flange stiffeners failed owing to web tearing after web and flange local buckling. The failure mode of the specimen with continuous welding between the web and flanges was local flange buckling. Finally, the paper presents a comparison between the experimental results and the European Code to predict the capacity of the flange towards local buckling. It was concluded that the non-welding the IFs affected the inelastic behaviour and the capacity of the SBCWs. In addition, the bending resistance equations presented by EN 1993-1-5 can safely predict the test results of the non-welded inclined fold and yield a high safe variation.
The huge amounts of old and damaged tires spread worldwide has caused many complex environmental risks. The old tires have been converted to crumb rubber (CR) and tire recycled steel fiber (RSF) to facilitate their use. This study used CR to partially replace natural sand in reinforced (RC) columns. Externally bonded (EB) carbon-fiber-reinforced polymer (CFRP) laminates, welded wire mesh (WWM), and RSF were used to enhance the axial behavior of the tested columns to overcome the concrete deficiencies resulting from the inclusion of the CR instead of natural sand. Eighteen columns were prepared and tested to discuss the effects of strengthening type, CR content, RSF, and strengthening area on the axial behavior of the RC columns. Certain columns were internally reinforced with WWM, while others were externally strengthened with EB CFRP laminates. Partially or fully EB CFRP laminates were used to strengthen the columns. Moreover, one column was cast with NC and 0.2% RSF to investigate the role of RSF in confining the column. The results demonstrated a concrete strength reduction for the rubberized concrete (CRC) as the CR content increased. Conversely, the strengthened columns experienced higher load capacities than the corresponding un-strengthened ones cast with the same concrete mix. Moreover, adding 2% RSF to the NC mix could enhance the column capacity, although it decreased the concrete strength. Furthermore, using two CFRP layers increased the load capacity and ductility of the strengthened columns. The strengthened column cast with 50% CR showed the highest load efficiency (334.3% compared to the un-strengthened one).
Steel beams’ shear strength is one of the most important factors that influence how quickly webs buckle. Despite extensive studies having been performed over the previous three decades, the existing procedures did not achieve the necessary reliability to predict the ultimate shear resistance of plate girders. New techniques called Learner Techniques have started to be used over the last few years; these techniques were applied to calculate the steel beam shear strength. In this study, a Regression Learner Techniques model was built using data from 100 test results from previously published research. Based on the geometric and material properties of the web and flanges available in the published tests, a model was built using Artificial Neural Networks. Based on sensitivity analysis, a Cascade Forward Backpropagation Neural Networks (CFBNN) approach was utilized to anticipate the shear strength of steel beams. The proposed models outperformed current hybrid artificial intelligence models developed using the same collected datasets and demonstrated to accurately predict the ultimate shear strength. The performance of the models was evaluated using a range of statistical assessment methods, which led to a valuable conclusion. The CFBNN model achieved the highest root mean square (R2 = 0.95). The results corresponding to each test were verified by specimen shear strength values calculated by a theoretical approach. The resultant maximum shear force obtained by the proposed modified equation was compared with the experimental results and the shear force was estimated using two different approaches proposed by the European code. Finally, two approaches were used to verify the proposed model. The first approach was the data reported from an experimental shear test program conducted by the authors, and the second was the results of the shear values acquired experimentally by other researchers. Based on the test results of the previous studies and the current work, the suggested model gives an adequate degree of accuracy for estimating the shear strength of steel beams.