Mohammed Ahsan Adib Murad

Mr. Mohammed Ahsan Adib Murad

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Georgios TzounasGeorgios Tzounas
Georgios Tzounas
Ioannis DassiosIoannis Dassios
Ioannis Dassios
MMMohammed Ahsan Adib Murad
Mohammed Ahsan Adib Murad
Federico MilanoFederico Milano
Federico Milano
The paper presents the theoretical foundation and practical implementation aspects of Fractional Order Controllers (FOCs) for power system applications. With this aim, the paper provides a comprehensive mathematical background on the stability analysis of dynamic systems with inclusion of fractional order derivatives and discusses their software implementation based on the Oustaloup's Recursive Approximation (ORA) method. Then the paper illustrates a variety of examples of ORA-based FOCs, namely, automatic generation control of synchronous machines; frequency control of a converter-interfaced energy storage system; and voltage control through a static synchronous compensator. The WSCC 9-bus test system and a realistic 1,479-bus model of the Irish transmission system are employed to test and compare the examined FOCs with their integer-order versions.

23 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Weilin ZhongWeilin Zhong
Weilin Zhong
JCJunru Chen
Junru Chen
MLMuyang Liu
Muyang Liu
MMMohammed Ahsan Adib Murad
Mohammed Ahsan Adib Murad
Federico MilanoFederico Milano
Federico Milano
The paper proposes a coordinated frequency control strategy for Virtual Power Plant (VPPs), with the inclusion of Distributed Energy Resource (DERs), e.g., Solar Photo-Voltaic Generation (SPVG), Wind Generator (WG) as well as Energy Storage System (ESS). The objective is to improve the short-term dynamic response of the overall power system. The robustness of the proposed control is evaluated through a Monte Carlo analysis and a detailed modeling of stochastic disturbances of loads, wind speed, and solar irradiance. The impact of communication delays of a variety of realistic communication networks with different bandwidths is also discussed and evaluated. The case study is based on a modified version of the WSCC 9-bus test system with inclusion of a VPP. This is modeled as a distribution network with inclusion of a variety of DERs.

17 March 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Yong WanYong Wan
Yong Wan
MMMohammed Ahsan Adib Murad
Mohammed Ahsan Adib Murad
MLMuyang Liu
Muyang Liu
Federico MilanoFederico Milano
Federico Milano
This paper proposes a decentralized control based on static var compensator (SVC) devices to improve the frequency control of high voltage transmission systems. For a realistic structure preserving power system with voltage dependent loads, we propose a sufficient condition based on a strict Lyapunov energy function, which is utilized to design a nonlinear adaptive SVC controller. This controller only requires local bus measures and parameters. Furthermore, we also present an SVC with a conventional frequency droop controller. The performance of the two considered SVC control systems are evaluated on the well known IEEE New England 39-bus 10-machine power system and compared with conventional SVC controllers.

15 April 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MMMohammed Ahsan Adib Murad
Mohammed Ahsan Adib Murad
Federico MilanoFederico Milano
Federico Milano
The paper discusses the modeling and the simulation of the limiters of proportional integral (PI) controllers included in voltage-sourced converters. Seven PI controller models are considered. These include windup and anti-windup limiters, back calculation with different gains and delayed feedback and the model recommended by the IEEE standard 421.5-2016. The dynamic behavior and numerical issues arising for each PI implementation are thoroughly compared by means of a detailed all-island dynamic model of the Irish system including the HVDC East–West Interconnector and a simplified dynamic model of the Great Britain system; and the Nordic system with inclusion of a STATCOM device. Recommendations on the computer-based implementation of each model are provided in the concluding remarks.

28 October 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
MMMichela Moschella
Michela Moschella
MMMohammed Ahsan Adib Murad
Mohammed Ahsan Adib Murad
ECEmanuele Crisostomi
Emanuele Crisostomi
Federico MilanoFederico Milano
Federico Milano
This paper focuses on the impact of the charge of Plug-in Electric Vehicles (PEVs) on the dynamic response of power systems and proposes an efficient solution to control electric vehicle chargers, by dynamically allocating the available power in an optimized way. The proposed approach is based on an Additive-Increase-Multiplicative-Decrease (AIMD) stochastic decentralized control strategy to efficiently and seamlessly manage the charge of a high number of PEVs with little communication efforts. A modified version of the New England network is utilized to validate the proposed control through a variety of scenarios and control setups.

23 February 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
TKTaulant Kërçi
Taulant Kërçi
MMMohammed Ahsan Adib Murad
Mohammed Ahsan Adib Murad
IDIoannis Dassios
Ioannis Dassios
Federico MilanoFederico Milano
Federico Milano
This paper discusses the impact of discrete secondary controllers on the dynamic response of power systems. The idea of the paper originates from the observation that there is a range of values, from few tens of seconds to few minutes, of the execution cycles of conventional automatic generation control (AGC) that leads to a limit cycle. Below and above this range the system is stable. This is certainly not a problem in practice as the AGC updates the power set points of generating units every few seconds. However, this phenomenon has interesting consequences if one considers real-time electricity markets with short dispatch periods (i.e., 5 minutes) as these markets can be modeled as a sort of AGC. The paper first provides a formal analogy between conventional AGC and real-time electricity markets. Then it shows that the discretization-driven instability exists if the system includes a real-time electricity market modeled as secondary frequency controller. Finally, the paper discusses the impact of the combined effect of high wind generation shares and discrete secondary controllers on power system dynamics.