The paper proposes a control scheme to improve the dynamic response of power systems through the automatic regulators of converter-based Distributed Energy Resources (DERs). In this scheme, both active and reactive power control of DERs are varied to regulate both frequency and voltage, as opposed to current practice where frequency and voltage controllers are decoupled. To assess the proposed control against the current state-of-art, the paper also defines a metric that captures the combined effect of frequency/voltage response at any given bus of the network. Results indicate that the proposed control strategy leads to a significant improvement in the stability and performance of the overall power system. These results are based on a comprehensive case study carried out by employing a modified version of the IEEE 39-bus benchmark system, where a portion of the synchronous machines is substituted by converter-interfaced DERs. The impact on the proposed control of load models, the $R/X$ ratio of network lines, as well as the level of DER penetration to the grid, are properly evaluated and conclusions are duly drawn.
The paper proposes a coordinated frequency control strategy for Virtual Power Plant (VPPs), with the inclusion of Distributed Energy Resource (DERs), e.g., Solar Photo-Voltaic Generation (SPVG), Wind Generator (WG) as well as Energy Storage System (ESS). The objective is to improve the short-term dynamic response of the overall power system. The robustness of the proposed control is evaluated through a Monte Carlo analysis and a detailed modeling of stochastic disturbances of loads, wind speed, and solar irradiance. The impact of communication delays of a variety of realistic communication networks with different bandwidths is also discussed and evaluated. The case study is based on a modified version of the WSCC 9-bus test system with inclusion of a VPP. This is modeled as a distribution network with inclusion of a variety of DERs.
1 December 2020 in Electric Power Systems Research
The uncertainty caused by renewable energy (RES) and diverse load demands may cause power flow fluctuations in modern power systems, where the probabilistic power flow (PPF) is a reliable method for quantifying and analyzing such power flow fluctuations. This paper proposes a higher-order Markov chain-based modeling framework to represent the stochastic behaviors of the photovoltaic (PV) output and load profiles. The proposed method effectively captures nonlinear temporal autocorrelations across multiple time intervals. In addition, by constructing joint probability distributions, the proposed method can not only handle the situation of linear correlations among distinct PV outputs and similar load types but also reveal nonlinear correlations between co-located PV generation and load variations. In addition, an inverse transformation strategy is developed to generate spatially and temporally correlated PV–load scenarios, ensuring more realistic system representations. Finally, the Mehler formula is adopted to calculate equivalent correlation coefficients under high-linearity conditions, which enhances the computational tractability of the overall approach. Numerical case studies demonstrate that our method achieves both accuracy and efficiency in PPF computations while preserving critical spatio-temporal correlation characteristics.
As renewable energy sources like wind and solar power increasingly replace traditional energy sources and are integrated into the power grid, the issue of insufficient system inertia is becoming more apparent. This paper presents an online adaptive time window inertia constant identification method based on ambient measurements to identify the equivalent inertia constant of the time-varying inertia at Point of Interface (POI) level. The proposed method takes advantage of the online inertia estimation and the data-driven equivalent inertia constant identification techniques to simultaneously achieve online tracking and accuracy. With this regard, this paper first describes the inertia providers in modern system. Then, based on the frequency and power data measured by the Phasor Measurement Unit (PMU), this paper provides an improved data-driven equivalent inertia constant identification method. Subsequently, the paper proposes an ambient data smoothing method to cope with the numerical errors and provides, as a byproduct, an adaptive time window inertia constant identification. The adaptive time window is designed to enhance the accuracy of the method. Finally, the feasibility and accuracy of the proposed method of tracking synthetic inertia are validated by the simulation tests based on a grid in northwest China with high renewable energy penetration and a Virtual Power Plant (VPP). The experimental results show that the accuracy of this method is within .