The aim of the present study was to quantify joint kinematics through a wearable sensor system in multidirectional high-speed complex movements used in a protocol for rehabilitation and return to sport assessment after Anterior Cruciate Ligament (ACL) injury, and to validate it against a gold standard optoelectronic marker-based system. Thirty-four healthy athletes were evaluated through a full-body wearable sensor (MTw Awinda, Xsens) and a marker-based optoelectronic (Vicon Nexus, Vicon) system during the execution of three tasks: drop jump, forward sprint, and 90° change of direction. Clinically relevant joint angles of lower limbs and trunk were compared through Pearson’s correlation coefficient (r), and the Coefficient of Multiple Correlation (CMC). An excellent agreement (r > 0.94, CMC > 0.96) was found for knee and hip sagittal plane kinematics in all the movements. A fair-to-excellent agreement was found for frontal (r 0.55–0.96, CMC 0.63–0.96) and transverse (r 0.45–0.84, CMC 0.59–0.90) plane kinematics. Movement complexity slightly affected the agreement between the systems. The system based on wearable sensors showed fair-to-excellent concurrent validity in the evaluation of the specific joint parameters commonly used in rehabilitation and return to sport assessment after ACL injury for complex movements. The ACL professionals could benefit from full-body wearable technology in the on-field rehabilitation of athletes.
Background: The World Health Organization stated an average of 60 min of Moderate to Vigorous Physical Activity (MVPA) that children should accumulate every day. Nevertheless physical inactivity is growing and, due to restrictions imposed during pandemic, PA levels of children might be more negatively affected. The study aimed to analyse the impact of COVID-19 on the PA of an Italian sample of primary school children by comparing it before and during COVID-19 considering gender differences. Methods: A pre-post analysis (October 2019–January 2021) was conducted using a randomized sample (N = 77) from the I-MOVE study settled in an Italian primary school. Both objective (Actigraph accelerometers) and self-reported (PAQ-c questionnaires) assessments of PA were performed. Changes were compared using T-Student and Chi-Square test. Gender differences were calculated using Anova. Results: Weekly and daily minutes time spent in MVPA significantly decreased respectively by − 30.59 ± 120.87 and − 15.32 ± 16.21 from before to during pandemic while the weekly time spent in sedentary behaviour increased (+ 1196.01 ± 381.49). PAQ-c scores followed the same negative trend (− 0.87 ± 0.72). Boys seem to have suffered more than girls from the imposed restrictions. Conclusion: These findings outline the need for strategies to promote PA and reduce sedentary behaviours in children to prevent COVID-19 restriction long-term effects.
Phase angle (PA) is a strong predictor of sarcopenia, fragility, and risk of mortality in obese people, while an optimal muscular function and handgrip strength (HS) are required to perform different daily activities. Although there is a general agreement that resistance training improves health status in obese people, the optimal weekly training frequency for PA and physical performance parameters is not clear. This study aimed to compare the effects of different weekly resistance training frequencies performed over a 24 week exercise program on PA and HS in obese people. Forty-two women (56.2 ± 9.1 years, body mass index (BMI) 37.1 ± 4.9 kg/m2) were randomly allocated to one of two groups: a group with a high weekly training frequency of three times a week (HIGH, n = 21) and a group that performed only one weekly session (LOW, n = 21). The groups trained with an identical exercise intensity and volume per session for 6 months. Before and after the intervention period, the participants were assessed for anthropometric measures, bioimpedance analysis, and HS. There was a significant group × time interaction (p < 0.05) for waist circumference, bioimpedance reactance divided by body height (Xc/H), PA, and HS measures. In addition, only the HIGH group increased Xc/H, PA, and HS after the intervention period (p < 0.05), even after adjusting for weight loss and menopausal status. Physical exercise performed three times a week promotes better adaptations in PA and HS when compared with the same program performed once a week in obese women.
6 April 2020 in Knee Surgery, Sports Traumatology, Arthroscopy
Purpose: The deceleration (pressing) is a common situational pattern leading to anterior cruciate ligament (ACL) injury in football. Although mainly assessed for performance purposes, a stronger focus on movement quality might support the screening of at‐risk athletes. The aim of the present study was to describe a 2D scoring system for the assessment of the deceleration task and to associate it with the knee joint loading (knee abduction moment) evaluated through the gold standard 3D motion capture. The hypothesis was that lower 2D scores would be associated with higher knee joint loading.Methods: Thirty‐four competitive football (soccer) players (age 22.8 ± 4.1, 16 females) performed a series of deceleration tasks. 3D motion analysis was recorded using ten stereophotogrammetric cameras, a force platform, and three high‐speed cameras. The 2D qualitative assessment was performed via a scoring system based on the video analysis of frontal and lateral planes joint kinematics for five scoring criteria. The intra‐ and inter‐rater reliabilities were calculated for each 2D scoring criteria. The peak knee abduction moment was extracted and grouped according to the results of the 2D evaluation.Results: An ICC > 0.94 was found for all the 2D scoring criteria, both for intra‐rater and inter‐rater reliability. The players with low 2D frontal plane scores and low total scores (0–4) showed significantly higher peak knee abduction moment values (p < 0.001). A significant negative rank correlation was found between the total score and the peak knee abduction moment (ρ = − 0.25, p < 0.001).Conclusions: The qualitative 2D scoring system described successfully discerned between athletes with high and low knee joint loading during a deceleration task. The application of this qualitative movement assessment based on a detailed and accurate scoring system is suitable to identify players and patients with high knee joint loading (high knee abduction moments) and target additional training in the scenario of the primary and secondary ACL injury risk reduction.Level of evidence: Level IV.