Accurate placement and stable fixation are the main goals of internal fixation of bone fractures using the traditional medical screws. These goals are necessary to expedite and avoid improper fracture healing due to misalignment of the bone fragments. However, the rigidity of the screw, geometry of the fractured anatomy (e.g., femur and pelvis), and osteoporosis may cause an array of complications. To address these challenges, we propose the use of a continuum manipulator and a bendable medical screw (BMS) to drill curved tunnels and fixate the bone fragments. This novel approach provides the clinicians with a degree of freedom in selecting the drilling entry point as well as the navigation of drill in complex anatomical and osteoporotic bones. This technique can also facilitate the treatment of osteonecrosis and augmentation of the hip to prevent osteoporotic fractures. In this paper: (1) we evaluated the performance of the curved drilling technique on human cadaveric specimens by making several curved tunnels with different curvatures and (2) we also demonstrated the feasibility of internal fixation using the BMS versus a rigid straight screw by performing finite element simulation of fracture fixation in an osteoporotic femur.
28 July 2020 in IEEE Transactions on Medical Robotics and Bionics
Femoroplasty is a proposed alternative therapeutic method for preventing osteoporotic hip fractures in the elderly. Previously developed navigation system for femoroplasty required the attachment of an external X-ray fiducial to the femur. We propose a fiducial-free 2D/3D registration pipeline using fluoroscopic images for robot-assisted femoroplasty. Intraoperative fluoroscopic images are taken from multiple views to perform registration of the femur and drilling/injection device. The proposed method was tested through comprehensive simulation and cadaveric studies. Performance was evaluated on the registration error of the femur and the drilling/injection device. In simulations, the proposed approach achieved a mean accuracy of 1.26 ± 0.74 mm for the relative planned injection entry point; 0.63 ± 0.21° and 0.17 ± 0.19° for the femur injection path direction and device guide direction, respectively. In the cadaver studies, a mean error of 2.64 ± 1.10 mm was achieved between the planned entry point and the device guide tip. The biomechanical analysis showed that even with a 4 mm translational deviation from the optimal injection path, the yield load prior to fracture increased by 40.7%. This result suggests that the fiducial-less 2D/3D registration is sufficiently accurate to guide robot assisted femoroplasty.
1 February 2023 in IEEE Transactions on Medical Robotics and Bionics
Minimally-invasive Osteoporotic Hip Augmentation (OHA) by injecting bone cement is a potential treatment option to reduce the risk of hip fracture. This treatment can significantly benefit from computer-assisted planning and execution system to optimize the pattern of cement injection. We present a novel robotic system for the execution of OHA that consists of a 6-DOF robotic arm and integrated drilling and injection component. The minimally-invasive procedure is performed by registering the robot and preoperative images to the surgical scene using multi-view image-based 2D/3D registration with no external fiducial attached to the body. The performance of the system is evaluated through experimental sawbone studies as well as cadaveric experiments with intact soft tissues. In the cadaver experiments, distance errors of 3.28 mm and 2.64 mm for entry and target points and orientation error of 2.30° are calculated. Moreover, the mean surface distance error of 2.13 mm with translational error of 4.47 mm is reported between injected and planned cement profiles. The experimental results demonstrate the first application of the proposed Robot-Assisted combined Drilling and Injection System (RADIS), incorporating biomechanical planning and intraoperative fiducial-less 2D/3D registration on human cadavers with intact soft tissues.
Periacetabular osteotomy (PAO) is a common surgical treatment for developmental dysplasia of the hip. To obtain the optimal method of fixation during PAO, different screw fixation techniques have been proposed for stabilizing the acetabular fragment. This study assesses the biomechanical performance of two popular 3-screw fixation techniques: iliac (IS) and transverse (IT) configurations, through finite element simulations. Additionally, different 2-screw combinations are simulated to investigate the biomechanical significance of each screw of the fixation configurations. The study findings show that yield load of the pelvic bone subject to gait loading for IT configuration is on average 7% higher compared to that of the IS. Although the yield load of the IT is predicted to be slightly higher, no significant difference in bone stiffness and displacement of the acetabular fragment are found between two configurations. Simulation results, therefore, do not demonstrate a significant biomechanical advantage of the IT configuration over the IS. Furthermore, the biomechanical comparison between the 2-screw combinations of IS and IT fixations demonstrates that the most anterior screw in IS, located at the iliac crest, and the most medial screw in the IT are the most critical elements in providing sufficient stability and support for acetabular fragment.