Image-based 2D/3D registration is a critical technique for fluoroscopic guided surgical interventions. Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions. In this work, we aim to extend the 2D/3D registration capture range with a fully differentiable deep network framework that learns to approximate a convex-shape similarity function. The network uses a novel Projective Spatial Transformer (ProST) module that has unique differentiability with respect to 3D pose parameters, and is trained using an innovative double backward gradient-driven loss function. We compare the most popular learning-based pose regression methods in the literature and use the well-established CMAES intensity-based registration as a benchmark. We report registration pose error, target registration error (TRE) and success rate (SR) with a threshold of 10mm for mean TRE. For the pelvis anatomy, the median TRE of ProST followed by CMAES is 4.4mm with a SR of 65.6% in simulation, and 2.2mm with a SR of 73.2% in real data. The CMAES SRs without using ProST registration are 28.5% and 36.0% in simulation and real data, respectively. Our results suggest that the proposed ProST network learns a practical similarity function, which vastly extends the capture range of conventional intensity-based 2D/3D registration. We believe that the unique differentiable property of ProST has the potential to benefit related 3D medical imaging research applications.
28 July 2020 in IEEE Transactions on Medical Robotics and Bionics
Femoroplasty is a proposed alternative therapeutic method for preventing osteoporotic hip fractures in the elderly. Previously developed navigation system for femoroplasty required the attachment of an external X-ray fiducial to the femur. We propose a fiducial-free 2D/3D registration pipeline using fluoroscopic images for robot-assisted femoroplasty. Intraoperative fluoroscopic images are taken from multiple views to perform registration of the femur and drilling/injection device. The proposed method was tested through comprehensive simulation and cadaveric studies. Performance was evaluated on the registration error of the femur and the drilling/injection device. In simulations, the proposed approach achieved a mean accuracy of 1.26 ± 0.74 mm for the relative planned injection entry point; 0.63 ± 0.21° and 0.17 ± 0.19° for the femur injection path direction and device guide direction, respectively. In the cadaver studies, a mean error of 2.64 ± 1.10 mm was achieved between the planned entry point and the device guide tip. The biomechanical analysis showed that even with a 4 mm translational deviation from the optimal injection path, the yield load prior to fracture increased by 40.7%. This result suggests that the fiducial-less 2D/3D registration is sufficiently accurate to guide robot assisted femoroplasty.
24 December 2021 in IEEE Transactions on Biomedical Engineering
We present an image-based navigation solution for a surgical robotic system with a Continuum Manipulator (CM). Our navigation system uses only fluoroscopic images from a mobile C-arm to estimate the CM shape and pose with respect to the bone anatomy. The CM pose and shape estimation is achieved using image intensity-based 2D/3D registration. A learning-based framework is used to automatically detect the CM in X-ray images, identifying landmark features that are used to initialize and regularize image registration. We also propose a modified hand-eye calibration method that numerically optimizes the hand-eye matrix during image registration. The proposed navigation system for CM positioning was tested in simulation and cadaveric studies. In simulation, the proposed registration achieved a mean error of $1.10\pm 0.72$ mm between the CM tip and a target entry point on the femur. In cadaveric experiments, the mean CM tip position error was $2.86\pm 0.80$ mm after registration and repositioning of the CM. The results suggest that our proposed fluoroscopic navigation is feasible to guide the CM in orthopedic applications.