S.W. Westra

Dr. S.W. Westra

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LHLuuk Heckman
Luuk Heckman
JLJustin G.L.M. Luermans
Justin G.L.M. Luermans
KCkarol curila
karol curila
ASAntonius M.W. Van Stipdonk
Antonius M.W. Van Stipdonk
SWS.W. Westra
S.W. Westra
KVKevin Vernooy
Kevin Vernooy
Background: Left bundle branch area pacing (LBBAP) has recently been introduced as a novel physiological pacing strategy. Within LBBAP, distinction is made between left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP, no left bundle capture). Objective: To investigate acute electrophysiological effects of LBBP and LVSP as compared to intrinsic ventricular conduction. Methods: Fifty patients with normal cardiac function and pacemaker indication for bradycardia underwent LBBAP. Electrocardiography (ECG) characteristics were evaluated during pacing at various depths within the septum: starting at the right ventricular (RV) side of the septum: the last position with QS morphology, the first position with r’ morphology, LVSP and—in patients where left bundle branch (LBB) capture was achieved—LBBP. From the ECG’s QRS duration and QRS morphology in lead V1, the stimulus- left ventricular activation time left ventricular activation time (LVAT) interval were measured. After conversion of the ECG into vectorcardiogram (VCG) (Kors conversion matrix), QRS area and QRS vector in transverse plane (Azimuth) were determined. Results: QRS area significantly decreased from 82 ± 29 µVs during RV septal pacing (RVSP) to 46 ± 12 µVs during LVSP. In the subgroup where LBB capture was achieved (n = 31), QRS area significantly decreased from 46 ± 17 µVs during LVSP to 38 ± 15 µVs during LBBP, while LVAT was not significantly different between LVSP and LBBP. In patients with normal ventricular activation and narrow QRS, QRS area during LBBP was not significantly different from that during intrinsic activation (37 ± 16 vs. 35 ± 19 µVs, respectively). The Azimuth significantly changed from RVSP (−46 ± 33°) to LVSP (19 ± 16°) and LBBP (−22 ± 14°). The Azimuth during both LVSP and LBBP were not significantly different from normal ventricular activation. QRS area and LVAT correlated moderately (Spearman’s R = 0.58). Conclusions: ECG and VCG indices demonstrate that both LVSP and LBBP improve ventricular dyssynchrony considerably as compared to RVSP, to values close to normal ventricular activation. LBBP seems to result in a small, but significant, improvement in ventricular synchrony as compared to LVSP.

1 August 2021 in EP Europace
Verified
Journal Article
Open access
SVStijn P G van Vugt
Stijn P G van Vugt
SWS.W. Westra
S.W. Westra
RVRick H J A Volleberg
Rick H J A Volleberg
GHGerjon Hannink
Gerjon Hannink
RNRena Nakamura
Rena Nakamura
MBMarc A Brouwer
Marc A Brouwer
Aims: At present, there are no guideline recommendations for minimally interrupted use of non-vitamin K antagonist oral anticoagulants (mi-NOAC) during catheter ablation (CA) for atrial fibrillation (AF). Current evidence is predominantly based on observational studies, with continuous use of vitamin K antagonist in the control arm. This quantitative summary reflects the first high-level evidence on contemporary regimens, with continuous NOAC use (c-NOAC) as the current gold standard. Methods and results: Meta-analysis (Pubmed, Embase, and Web of Science) on prospective, controlled studies comparing contemporary mi-NOAC (without bridging) with c-NOAC. Net adverse clinical events (major bleeding, thrombo-embolic events) were the primary outcome. In addition, we analysed total bleeding, minor bleeding, and silent cerebral embolism. Eight studies (six randomized, two observational) with 2168 patients were summarized. The primary endpoint occurred in 1.0% (18/1835): 1.1% (11/1005) vs. 0.8% (7/830) for the mi-NOAC and c-NOAC groups, respectively; odds ratio (OR) 1.20 [95% confidence interval (CI) 0.49–2.92, P = 0.64]. The OR for total bleeding on mi-NOAC was 1.26 (95% CI 0.97–1.63, P = 0.07). ORs for minor bleeding and silent cerebral embolism were 1.17 (95% CI 0.80–1.70, P = 0.34) and 2.62 (95% CI 0.54–12.61, P = 0.12), respectively. Conclusion: This synopsis provides a quantitative synthesis of high-level evidence on a contemporary strategy of mi-NOAC in CA for AF, and overall clinical outcomes were not different from continuous NOAC use. Despite preprocedural interruption, there was no sign of lower bleeding rates. Additional higher volume datasets are warranted for more precise treatment effect estimations of this everyday alternative anticoagulation strategy in AF ablation.

23 September 2024 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
JRJesse Rijks
Jesse Rijks
LHLuuk Heckman
Luuk Heckman
SWS.W. Westra
S.W. Westra
RCRichard Cornelussen
Richard Cornelussen
SGSubham Ghosh
Subham Ghosh
KVKevin Vernooy
Kevin Vernooy
Introduction: Left bundle branch area pacing (LBBAP) comprises pacing at the left ventricular septum (LVSP) or left bundle branch (LBBP). The aim of the present study was to investigate the differences in ventricular electrical heterogeneity between LVSP, LBBP, right ventricular pacing (RVP) and intrinsic conduction with different dyssynchrony measures using the ECG, vectorcardiograpy, ECG belt, and Ultrahigh frequency (UHF‐)ECG.Methods: Thirty‐seven patients with a pacemaker indication for bradycardia or cardiac resynchronization therapy underwent LBBAP implantation. ECG, vectorcardiogram, ECG belt and UHF‐ECG signals were recorded during RVP, LVSP and LBBP, and intrinsic activation. QRS duration (QRSd) was measured from the ECG, QRS area was calculated from the vectorcardiogram, LV activation time (LVAT) and standard deviation of activation time (SDAT) from ECG belt and electrical dyssynchrony (e‐DYS16) from UHF‐ECG.Results: Both LVSP and LBBP significantly reduced ventricular electrical heterogeneity as compared to underlying LBBB and RV pacing in terms of QRS area (p < .001), SDAT (p < .001), LVAT (p < .001) and e‐DYS16 (p < .001). QRSd was only reduced as compared to RV pacing(p < .001). QRS area was similar during LBBP and normal intrinsic conduction, e‐DYS16 was similar during LVSP and normal intrinsic conduction, whereas SDAT was similar for LVSP, LBBP and normal intrinsic conduction. For all these variables there was no significant difference between LVSP and LBBP.Conclusion: Both LVSP and LBBP resulted in a more synchronous LV activation than LBBB and RVP. Especially LBBP resulted in levels of LV synchrony comparable to normal intrinsic conduction.

8 August 2018 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Open access
PDF file
SWS.W. Westra
S.W. Westra
SVStijn P. G. van Vugt
Stijn P. G. van Vugt
SSSümeyye Sezer
Sümeyye Sezer
REReinder Evertz
Reinder Evertz
MHMartin E. Hemels
Martin E. Hemels
GCGian-Battista Chierchia
Gian-Battista Chierchia
Currently, information on the optimal approach of redo procedures for paroxysmal atrial fibrillation (PAF) is limited. Radiofrequency ablation is the preferred technique, with reported success rates of 50–70% at 1–2 years, whereas only few reports exist on redo cryoballoon (CB) ablations. We describe outcomes on a systematic approach of repeat procedures with a second-generation cryoballoon (CB-2) after a successful index CB ablation.

1 November 2015 in Resuscitation
Verified
Journal Article
Closed access
JBJudith L. Bonnes
Judith L. Bonnes
JTJos Thannhauser
Jos Thannhauser
MHMathilde C. Hermans
Mathilde C. Hermans
SWS.W. Westra
S.W. Westra
TOThom F. Oostendorp
Thom F. Oostendorp
JSJoep L.R.M. Smeets
Joep L.R.M. Smeets

17 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMohammed Ali Ghossein
Mohammed Ali Ghossein
FZFrancesco Zanon
Francesco Zanon
FSFloor Salden
Floor Salden
ASAntonius M.W. Van Stipdonk
Antonius M.W. Van Stipdonk
LMlina marcantoni
lina marcantoni
KVKevin Vernooy
Kevin Vernooy
Background: Reduction in QRS area after cardiac resynchronization therapy (CRT) is associated with improved long-term clinical outcome. The aim of this study was to investigate whether the reduction in QRS area is associated with hemodynamic improvement by pacing different LV sites and can be used to guide LV lead placement. Methods: Patients with a class Ia/IIa CRT indication were prospectively included from three hospitals. Acute hemodynamic response was assessed as the relative change in maximum rate of rise of left ventricular (LV) pressure (%∆LVdP/dtmax). Change in QRS area (∆QRS area), in QRS duration (∆QRS duration), and %∆LVdP/dtmax were studied in relation to different LV pacing locations within a patient. Results: Data from 52 patients paced at 188 different LV pacing sites were investigated. Lateral LV pacing resulted in a larger %∆LVdP/dtmax than anterior or posterior pacing (p = 0.0007). A similar trend was found for ∆QRS area (p = 0.001) but not for ∆QRS duration (p = 0.23). Pacing from the proximal electrode pair resulted in a larger %∆LVdP/dtmax (p = 0.004), and ∆QRS area (p = 0.003) but not ∆QRS duration (p = 0.77). Within patients, correlation between ∆QRS area and %∆LVdP/dtmax was 0.76 (median, IQR 0.35; 0,89). Conclusion: Within patients, ∆QRS area is associated with %∆LVdP/dtmax at different LV pacing locations. Therefore, QRS area, which is an easily, noninvasively obtainable and objective parameter, may be useful to guide LV lead placement in CRT.