The integration of wind energy systems (WECS) into the power grid through power electronic converters should ensure the high performance of the control system. In spite of several advantages of conventional Finite control set-model predictive controller (FCS-MPC), variable switching frequency and high computational burden are considered its main drawbacks. In this paper, a fast FCS-MPC of a machine side converter (MSC) of direct-driven permanent magnet synchronous generator (PMSG) based wind turbines for wind energy conversion system is proposed. The wind energy conversion system has been realized using a direct driven PMSG and a full-scale back-to-back power converter. The proposed controller is designed to reduce the required calculations in each horizon. In addition, the performance of conventional FCS-MPC is compared with the proposed method, and an improvement in total harmonic distortion spectra and simulation time required even when imposing a lower sampling frequency was found. To overcome the variable switching frequency problem, a modulation algorithm is introduced in the minimization process of modulated FCS-MPC. To keep the proposed system attached to the utility during a fault, a coordinated pitch angle control and low voltage-ride through (LVRT) algorithm is designed and inserted in the vector control of the grid side converter (GSC) to supply reactive power to the grid during fault for ensuring safe operation of the inverter and meeting the grid code requirements. The effectiveness of the proposed controller is illustrated using simulation results under different operating conditions.
The parameters of electric machines play a substantial role in the control system which, in turn, has a great impact on machine performance. In this paper, a proposed optimal estimation method for the electrical parameters of induction motors is presented. The proposed method uses the particle swarm optimization (PSO) technique. Further, it also considers the influence of temperature on the stator resistance. A complete experimental setup was constructed to validate the proposed method. The estimated electrical parameters of a 3.8-hp induction motor are compared with the measured values. A heat run test was performed to compare the effect of temperature on the stator resistance based on the proposed estimation method and the experimental measurements at the same conditions. It is shown that acceptable accuracy between the simulated results and the experimental measurements has been achieved.
About Me
Beni-Suef University
Faculty of Engineering
Electrical department
Beni-Suef University
Faculty of Engineering
Electrical department