Yoshiaki Kataoka

Mr. Yoshiaki Kataoka


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoshiaki Kataoka
Yoshiaki Kataoka
TITomoya Ishida
Tomoya Ishida
SOSatoshi Osuka
Satoshi Osuka
RTRyo Takeda
Ryo Takeda
STShigeru Tadano
Shigeru Tadano
HTHarukazu Tohyama
Harukazu Tohyama
Few studies have reported on the validity of a sensor-based lower-limb kinematics evaluation during the timed up and go (TUG) test. This study aimed to determine the validity of a wearable gait sensor system for measuring lower-limb kinematics during the TUG test. Ten young healthy participants were enrolled, and lower-limb kinematics during the TUG test were assessed using a wearable gait sensor system and a standard optical motion analysis system. The angular velocities of the hip, knee, and ankle joints in sit-to-stand and turn-to-sit phases were significantly correlated between the two motion analysis systems (R = 0.612–0.937). The peak angles and ranges of motion of hip, knee, and ankle joints in the walking-out and walking-in phases were also correlated in both systems (R = 0.528–0.924). These results indicate that the wearable gait sensor system is useful for evaluating lower-limb kinematics not only during gait, but also during the TUG test.

8 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoshiaki Kataoka
Yoshiaki Kataoka
RTRyo Takeda
Ryo Takeda
STShigeru Tadano
Shigeru Tadano
TITomoya Ishida
Tomoya Ishida
YSYuki Saito
Yuki Saito
HTHarukazu Tohyama
Harukazu Tohyama
Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.

Verified
Journal Article
Open access
PDF file
KOKumiko Okino
Kumiko Okino
MAMitsuhiro Aoki
Mitsuhiro Aoki
MYMasahiro Yamane
Masahiro Yamane
YKYoshiaki Kataoka
Yoshiaki Kataoka
ANAsami Nitta
Asami Nitta
CKChikashi Kohmura
Chikashi Kohmura
Introduction: Prolonged sitting causes leg discomfort. We evaluated shear wave velocity (SWV) of leg muscles, leg circumference, and leg discomfort associated with 2 h sitting. Methods: Twenty-one middle-aged men and 19 middle-aged women participated in the study. SWV and leg circumference was measured just after sitting, 60 min, 120 min, and after 3 min of leg raising. Leg discomfort was assessed before sitting and 120 min. Results: SWV was significantly greater in men than women and increased over time, and decreased with leg raising. The percentage increase in lower leg circumference was significantly greater in women than in men, and it increased over time. Leg discomfort significantly increased after 120 min in both men and women. Discussions: Because SWV is proportional to an increase in intramuscular compartment pressure in the lower leg, intramuscular compartment pressure increased over time with sitting and decreased with leg raising. Considering the changes in SWV and leg circumference, it was inferred that prolonged sitting causes an increase in intramuscular compartment pressure and intravascular blood volume, as well as an increase in water content in the leg subcutaneous tissue. Leg discomfort was estimated to be due to increased intra-leg fluid. Brief leg raising may resolve leg edema and discomfort.