Shigeru Tadano

Prof. Shigeru Tadano

National Institute of Technology, Hakodate College, Hakodatate, Japan and Hokkaido University, Sapporo, Japan
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMarco GHISLIERI
Marco GHISLIERI
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli
STShigeru Tadano
Shigeru Tadano
Valentina AgostiniValentina Agostini
Valentina Agostini
Wearable sensors are de facto revolutionizing the assessment of standing balance. The aim of this work is to review the state-of-the-art literature that adopts this new posturographic paradigm, i.e., to analyse human postural sway through inertial sensors directly worn on the subject body. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 73 full-text articles, selecting 47 high-quality contributions. A good inter-rater reliability was obtained (Cohen’s kappa = 0.79). This selection of papers was used to summarize the available knowledge on the types of sensors used and their positioning, the data acquisition protocols and the main applications in this field (e.g., “active aging”, biofeedback-based rehabilitation for fall prevention, and the management of Parkinson’s disease and other balance-related pathologies), as well as the most adopted outcome measures. A critical discussion on the validation of wearable systems against gold standards is also presented.

19 July 2013 in Sensors
Verified
Journal Article
Open access
PDF file
STShigeru Tadano
Shigeru Tadano
RTRyo Takeda
Ryo Takeda
HMHiroaki Miyagawa
Hiroaki Miyagawa
This paper proposes a method for three dimensional gait analysis using wearable sensors and quaternion calculations. Seven sensor units consisting of a tri-axial acceleration and gyro sensors, were fixed to the lower limbs. The acceleration and angular velocity data of each sensor unit were measured during level walking. The initial orientations of the sensor units were estimated using acceleration data during upright standing position and the angular displacements were estimated afterwards using angular velocity data during gait. Here, an algorithm based on quaternion calculation was implemented for orientation estimation of the sensor units. The orientations of the sensor units were converted to the orientations of the body segments by a rotation matrix obtained from a calibration trial. Body segment orientations were then used for constructing a three dimensional wire frame animation of the volunteers during the gait. Gait analysis was conducted on five volunteers, and results were compared with those from a camera-based motion analysis system. Comparisons were made for the joint trajectory in the horizontal and sagittal plane. The average RMSE and correlation coefficient (CC) were 10.14 deg and 0.98, 7.88 deg and 0.97, 9.75 deg and 0.78 for the hip, knee and ankle flexion angles, respectively.

1 January 2014 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
SES. Elmorsy
S. Elmorsy
TFT. Funakoshi
T. Funakoshi
FSF. Sasazawa
F. Sasazawa
MTMasahiro Todoh
Masahiro Todoh
STShigeru Tadano
Shigeru Tadano
NINorimasa Iwasaki
Norimasa Iwasaki

5 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
RTRyo Takeda
Ryo Takeda
GLGiulia Lisco
Giulia Lisco
TFTadashi Fujisawa
Tadashi Fujisawa
LGLaura Gastaldi
Laura Gastaldi
HTHarukazu Tohyama
Harukazu Tohyama
STShigeru Tadano
Shigeru Tadano
Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.

1 December 2011 in Science and Technology of Advanced Materials
Verified
Journal Article
Open access
STShigeru Tadano
Shigeru Tadano
BGBijay Giri
Bijay Giri
To understand the characteristics of bone at the tissue level, the structure, organization and mechanical properties of the underlying levels down to the nanoscale as well as their mutual interactions need to be investigated. Such information would help understand changes in the bone properties including stiffness, strength and toughness and provide ways to assess the aged and diseased bones and the development of next generation of bio-inspired materials. X-ray diffraction techniques have gained increased interest in recent years as useful non-destructive tools for investigating the nanostructure of bone. This review provides an overview on the recent progress in this field and briefly introduces the related experimental approach. The application of x-ray diffraction to elucidating the structural and mechanical properties of mineral crystals in bone is reviewed in terms of characterization of in situ strain, residual stress–strain and crystal orientation.

14 February 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
PDF file
STShigeru Tadano
Shigeru Tadano
RTRyo Takeda
Ryo Takeda
KSKeita Sasaki
Keita Sasaki
TFTadashi Fujisawa
Tadashi Fujisawa
HTHarukazu Tohyama
Harukazu Tohyama