This paper proposes a method for three dimensional gait analysis using wearable sensors and quaternion calculations. Seven sensor units consisting of a tri-axial acceleration and gyro sensors, were fixed to the lower limbs. The acceleration and angular velocity data of each sensor unit were measured during level walking. The initial orientations of the sensor units were estimated using acceleration data during upright standing position and the angular displacements were estimated afterwards using angular velocity data during gait. Here, an algorithm based on quaternion calculation was implemented for orientation estimation of the sensor units. The orientations of the sensor units were converted to the orientations of the body segments by a rotation matrix obtained from a calibration trial. Body segment orientations were then used for constructing a three dimensional wire frame animation of the volunteers during the gait. Gait analysis was conducted on five volunteers, and results were compared with those from a camera-based motion analysis system. Comparisons were made for the joint trajectory in the horizontal and sagittal plane. The average RMSE and correlation coefficient (CC) were 10.14 deg and 0.98, 7.88 deg and 0.97, 9.75 deg and 0.78 for the hip, knee and ankle flexion angles, respectively.

5 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
RTRyo Takeda
Ryo Takeda
GLGiulia Lisco
Giulia Lisco
TFTadashi Fujisawa
Tadashi Fujisawa
LGLaura Gastaldi
Laura Gastaldi
HTHarukazu Tohyama
Harukazu Tohyama
STShigeru Tadano
Shigeru Tadano
Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.

28 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
VRValeria Rosso
Valeria Rosso
Valentina AgostiniValentina Agostini
Valentina Agostini
RTRyo Takeda
Ryo Takeda
STShigeru Tadano
Shigeru Tadano
LGLaura Gastaldi
Laura Gastaldi
Overweight/obesity is a physical condition that affects daily activities, including walking. The main purpose of this study was to identify if there is a relationship between body mass index (BMI) and gait characteristics in young adults. 12 normal weight (NW) and 10 overweight/obese (OW) individuals walked at a self-selected speed along a 14 m indoor path. H-Gait system, combining seven inertial sensors (fixed on pelvis and lower limbs), was used to record gait data. Walking speed, spatio-temporal parameters and joint kinematics in 3D were analyzed. Differences between NW and OW and correlations between BMI and gait parameters were evaluated. Conventional spatio-temporal parameters did not show statistical differences between the two groups or correlations with the BMI. However, significant results were pointed out for the joint kinematics. OW showed greater hip joint angles in frontal and transverse planes, with respect to NW. In the transverse plane, OW showed a greater knee opening angle and a shorter length of knee and ankle trajectories. Correlations were found between BMI and kinematic parameters in the frontal and transverse planes. Despite some phenomena such as soft tissue artifact and kinematics cross-talk, which have to be more deeply assessed, current results show a relationship between BMI and gait characteristics in young adults that should be looked at in osteoarthritis prevention.

6 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoshiaki Kataoka
Yoshiaki Kataoka
YSYuki Saito
Yuki Saito
RTRyo Takeda
Ryo Takeda
TITomoya Ishida
Tomoya Ishida
STShigeru Tadano
Shigeru Tadano
HTHarukazu Tohyama
Harukazu Tohyama
Few studies have dealt with lower-limb kinematics during the timed up and go (TUG) test in subjects with locomotive syndrome (LS). This study aimed to evaluate the characteristics of lower-limb kinematics during the TUG test in subjects with LS using the wearable sensor-based H-Gait system. A total of 140 participants were divided into the non-LS (n = 28), the LS-stage 1 (n = 78), and LS-stage 2 (n = 34) groups based on the LS risk test. Compared with the non-LS group, the LS-stage 1 and LS-stage 2 groups showed significantly smaller angular velocity of hip and knee extension during the sit-to-stand phase. The LS-stage 2 group showed significantly smaller peak angles of hip extension and flexion during the walking-out phase compared to the non-LS group. These findings indicate that the evaluation of the lower-limb kinematics during the TUG test using the H-Gait system is highly sensitive to detect LS, compared with the evaluation of the lower-limb kinematics when simply walking.

1 February 2022 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
RTRyo Takeda
Ryo Takeda
FSFumiya Sato
Fumiya Sato
HYHiroichi Yokoyama
Hiroichi Yokoyama
KSKatsuhiko Sasaki
Katsuhiko Sasaki
NONobuyuki Oshima
Nobuyuki Oshima
HKHiroyuki Kamiya
Hiroyuki Kamiya

29 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoshiaki Kataoka
Yoshiaki Kataoka
TITomoya Ishida
Tomoya Ishida
SOSatoshi Osuka
Satoshi Osuka
RTRyo Takeda
Ryo Takeda
STShigeru Tadano
Shigeru Tadano
HTHarukazu Tohyama
Harukazu Tohyama
Few studies have reported on the validity of a sensor-based lower-limb kinematics evaluation during the timed up and go (TUG) test. This study aimed to determine the validity of a wearable gait sensor system for measuring lower-limb kinematics during the TUG test. Ten young healthy participants were enrolled, and lower-limb kinematics during the TUG test were assessed using a wearable gait sensor system and a standard optical motion analysis system. The angular velocities of the hip, knee, and ankle joints in sit-to-stand and turn-to-sit phases were significantly correlated between the two motion analysis systems (R = 0.612–0.937). The peak angles and ranges of motion of hip, knee, and ankle joints in the walking-out and walking-in phases were also correlated in both systems (R = 0.528–0.924). These results indicate that the wearable gait sensor system is useful for evaluating lower-limb kinematics not only during gait, but also during the TUG test.