Lei Dong

Dr. Lei Dong

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Lei DongLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
Mechanical pressures affect the rate and quality of dermal wound healing. It is therefore important to continuously monitor the mechanical pressure on a wound site so as to evaluate neovascularization and cellular proliferation under pressure. Based on an LC (inductor-capacitor) passive wireless principle, this paper presents the design, fabrication, and measurement of LC sensors embedded in a commercial bandage. Pyramidal PDMS (polydimethylsiloxane) elastomers used as the dielectric of the capacitive pressure sensor were fabricated by using a silicon anisotropic etching mold. Simulation and analysis of the LC sensor as well as wound environment effects were performed. The sensor embedded in the bandage stuck on the skin was measured, showing that its resonant frequency changes according to a linear function of applied pressure in a range of 0-200 mmHg with a sensitivity of -270.8 kHz/mmHg. The demonstrated LC sensor is completely flexible and wearable, which is proper for the future smart bandage.

29 October 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
DCDong-Yan Chen
Dong-Yan Chen
Lei DongLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
An inductor–capacitor passive wireless sensor is essential to physical, chemical, and biological sensing for scenarios where physical access is difficult. Exceptional points of parity-time symmetric inductor–capacitor systems featuring the linear loss and gain have been utilized for enhancing sensing. However, the exceptional point sensing scheme might bring about fundamental resolution limits and noise enhancement. Here we show, employing a nonlinear saturable gain, the responsivity has a cube-root singularity distinct from a square-root singularity of the linear exceptional point scheme. The saturable gain eliminates the imaginary part of the eigenfrequencies and significantly suppresses the noise. Through an example of inductor–capacitor wireless wearable temperature sensors, we demonstrate the high figure of merit for the nonlinear PT-symmetric configuration. Our results resolve a debate on the effectiveness of the exceptional point sensing scheme for inductor–capacitor sensors and provide a way of enhancing precision for these types of sensors.

12 March 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Lei DongLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
A passive inductor-capacitor (LC) wireless sensor is capable of continuous real-time detection in applications that require the sensor to be powered remotely and to occupy a small volume, such as harsh and sealed environments, where physical access is difficult. However, the previously reported sensor can only monitor one single parameter of interest at a time. Here, we report a symmetric LC topological circuit configuration that consists of two LC resonators and show that it can be used to monitor double parameters simultaneously. The symmetric LC configuration separates the resonant frequency of the two different LC resonators at the circuit networks from each other. We demonstrate the use of this configuration to detect both pressure and humidity. In our prototypes, the Polydimethylsiloxane elastomer with pyramidal microstructures was utilized to fabricate the pressure sensor, and graphene oxide was utilized to fabricate the humidity sensor. Experiments demonstrate that the sensitivity of the pressure sensor is -48.5 kHz/mmHg and the sensitivity of the humidity sensor is -67.7 kHz/%RH, showing that the sensors are independently response to pressure or humidity. Overall, this symmetric LC topological circuit configuration that consists of multiple LC resonators represents a versatile approach for multiple parameters monitoring.

15 October 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Lei DongLei Dong
Lei Dong
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Qing-An HuangQing-An Huang
Qing-An Huang
Inductor-capacitor (LC) sensors utilize magnetic coupling to transfer signals to the readout coil, realizing a passive wireless working pattern. They are of high use in situations where wired connections are impossible to be established. An increasing number of demands, arising from the emerging applications in the Internet of Things and portable devices, require a simultaneous monitoring in sensors. This paper proposes a branching inductor to implement multiple resonances in a single inductor. Each branch of the inductor forms a secondary inductance, which is connected with a sensitive capacitor to work as an LC sensor. The multiple resonances in the branching inductor work in a multi-mode coupling pattern. The coupling, comprising inductive coupling, and capacitive coupling is analyzed and detected. In experiments, a double branching inductor is fabricated on PET substrate. Two sensitive capacitors for humidity and pressure, respectively, are connected to the inductor, resulting in two resonant peaks to monitor the ambient humidity and pressure level. The experimental results are decoupled to obtain final outcomes: the humidity sensor can respond from 15%RH ~ 90%RH with a sensitivity of -45.3 kHz/%RH; and the pressure sensor can work from 750 mmHg ~1000 mmHg with a sensitivity of -811.2 kHz/mmHg.

26 July 2018 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Lei DongLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
This letter has experimentally investigated the effect of the external bending on inductor-capacitor ( LC ) wireless humidity sensors fabricated on flexible polyethylene terephthalate (PET) substrates. The LC humidity sensor consisting of interdigitated electrodes for the capacitor was fabricated on the PET substrate by a screen-printing method, and graphene oxide was utilized as the humidity sensing material. The measured sensitivity of the LC humidity sensor is -136.1 kHz/%RH. The behavior of the LC sensor when subjected to circular bending implemented by a customized bending setup has been tested through changes in resonant frequency. The ratio of the projected area under bending constraints to the initial area of the sensor is proposed to characterize the curvature of the sensor. It shows that the bending causes the ratio to decrease, which results in the resonant frequency ascent with the fitting slope being approximately 10.8 MHz/ratio for the ratio from 1 to 0.6. The reduction in capacitance and inductance of the LC sensor is subjected to circular bending accounts for the resonant frequency ascent. The results presented here would be a valuable reference for the future applications of the LC sensor on the flexible substrates. [2018-0066].

26 June 2020 in ACS Sensors
Verified
Journal Article
Closed access
Lei DongLei Dong
Lei Dong
PRPaolo S. Ravaynia
Paolo S. Ravaynia
Qing-An HuangQing-An Huang
Qing-An Huang
AHAndreas Hierlemann
Andreas Hierlemann
MMMario M. Modena
Mario M. Modena