Lifeng Wang

Dr. Lifeng Wang

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Lei DongLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
Mechanical pressures affect the rate and quality of dermal wound healing. It is therefore important to continuously monitor the mechanical pressure on a wound site so as to evaluate neovascularization and cellular proliferation under pressure. Based on an LC (inductor-capacitor) passive wireless principle, this paper presents the design, fabrication, and measurement of LC sensors embedded in a commercial bandage. Pyramidal PDMS (polydimethylsiloxane) elastomers used as the dielectric of the capacitive pressure sensor were fabricated by using a silicon anisotropic etching mold. Simulation and analysis of the LC sensor as well as wound environment effects were performed. The sensor embedded in the bandage stuck on the skin was measured, showing that its resonant frequency changes according to a linear function of applied pressure in a range of 0-200 mmHg with a sensitivity of -270.8 kHz/mmHg. The demonstrated LC sensor is completely flexible and wearable, which is proper for the future smart bandage.

19 January 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
MZMan-Na Zhang
Man-Na Zhang
LDLei Dong
Lei Dong
LWLifeng Wang
Lifeng Wang
Qing-An HuangQing-An Huang
Qing-An Huang
Exceptional points (EPs) have recently emerged as a new method for engineering the response of open physical systems, that is, systems that interact with the environment. The systems at the EPs exhibit a strong response to a small perturbation. Here, we show a method by which the sensitivity of silicon resonant sensors can be enhanced when operated at EPs. In our experiments, we use a pair of mechanically coupled silicon micromechanical resonators constituting a parity–time (PT)-symmetric dimer. Small perturbations introduced on the mechanically coupled spring cause the frequency to split from the EPs into the PT-symmetric regime without broadening the two spectrum linewidths, and this frequency splitting scales with the square root of the perturbation strength. The overall signal-to-noise ratio is still greatly enhanced, although the measured noise spectral density of the EP sensing scheme has a slight increase comparable to the traditional counterpart. Our results pave the way for resonant sensors with ultrahigh sensitivity.

9 June 2020 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
BZBin-Bin Zhou
Bin-Bin Zhou
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
LDLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
Inductor-capacitor (LC) passive wireless sensors are implemented by loose coupling between an external read-out coil and an inductor that receives power through this inductive coupling. They allow for continuous real-time detection in harsh or sealed environments where physical access is difficult. Changes in the sensors are wirelessly and remotely detected by the read-out coil. For implanted medical devices or sealed package applications, however, geometrical constraints such as small and noninvasive coils reduce the inductive coupling, turning the remote distance into a fundamental challenge. Here we propose theoretically and demonstrate experimentally that a parity-time (PT) symmetry breaking regime can be utilized to extend the remote distance of the LC passive wireless sensors. In our prototypes, a capacitive humidity sensor is fabricated with graphene oxide (GO) as a sensing material. The variable capacitance in the external read-out coil is cyclic scanned so as to keep the PT-symmetric configuration. Our results show that the read-out distance of the sensors with the PT-symmetric configuration is approximately 4 times as long as that with conventional methods while keeping the same for their sensitivity. The use of PT-symmetry-breaking regimes for the LC passive wireless sensors should enable the interrogation of applications in the implanted or sealed fields.

12 March 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Lei DongLei Dong
Lei Dong
Qing-An HuangQing-An Huang
Qing-An Huang
A passive inductor-capacitor (LC) wireless sensor is capable of continuous real-time detection in applications that require the sensor to be powered remotely and to occupy a small volume, such as harsh and sealed environments, where physical access is difficult. However, the previously reported sensor can only monitor one single parameter of interest at a time. Here, we report a symmetric LC topological circuit configuration that consists of two LC resonators and show that it can be used to monitor double parameters simultaneously. The symmetric LC configuration separates the resonant frequency of the two different LC resonators at the circuit networks from each other. We demonstrate the use of this configuration to detect both pressure and humidity. In our prototypes, the Polydimethylsiloxane elastomer with pyramidal microstructures was utilized to fabricate the pressure sensor, and graphene oxide was utilized to fabricate the humidity sensor. Experiments demonstrate that the sensitivity of the pressure sensor is -48.5 kHz/mmHg and the sensitivity of the humidity sensor is -67.7 kHz/%RH, showing that the sensors are independently response to pressure or humidity. Overall, this symmetric LC topological circuit configuration that consists of multiple LC resonators represents a versatile approach for multiple parameters monitoring.

15 October 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Lei DongLei Dong
Lei Dong
WDWen-Jun Deng
Wen-Jun Deng
LWLifeng Wang
Lifeng Wang
Qing-An HuangQing-An Huang
Qing-An Huang
Inductor-capacitor (LC) sensors utilize magnetic coupling to transfer signals to the readout coil, realizing a passive wireless working pattern. They are of high use in situations where wired connections are impossible to be established. An increasing number of demands, arising from the emerging applications in the Internet of Things and portable devices, require a simultaneous monitoring in sensors. This paper proposes a branching inductor to implement multiple resonances in a single inductor. Each branch of the inductor forms a secondary inductance, which is connected with a sensitive capacitor to work as an LC sensor. The multiple resonances in the branching inductor work in a multi-mode coupling pattern. The coupling, comprising inductive coupling, and capacitive coupling is analyzed and detected. In experiments, a double branching inductor is fabricated on PET substrate. Two sensitive capacitors for humidity and pressure, respectively, are connected to the inductor, resulting in two resonant peaks to monitor the ambient humidity and pressure level. The experimental results are decoupled to obtain final outcomes: the humidity sensor can respond from 15%RH ~ 90%RH with a sensitivity of -45.3 kHz/%RH; and the pressure sensor can work from 750 mmHg ~1000 mmHg with a sensitivity of -811.2 kHz/mmHg.

22 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MXMing-Zhu Xie
Ming-Zhu Xie
LWLifeng Wang
Lifeng Wang
BZBin-Bin Zhou
Bin-Bin Zhou
Qing-An HuangQing-An Huang
Qing-An Huang
This paper presents an impedance matching method for increasing the readout distance of an inductor-capacitor (LC) passive wireless sensor. When the impedance of the LC sensor system is equal to that of the measurement system, there is no reflection between the LC sensor system and the measurement system, which maximizes signal-to-noise ratio and readout distance. Complex impedance matching networks at the readout port of the LC sensor system have been analyzed and simulated. The matching capacitor at the readout port is required to change with the sensing capacitor in the LC sensor in order to maintain the same resonant frequency in both readout port and LC sensor. The matching resistor at the readout port has been analyzed and optimized. A varactor-based capacitor was inserted as the matching capacitor, which can be controlled by a DC voltage so that the resonant frequency of the readout port can be scanned within the full range of resonant frequency in the LC sensor. A capacitive humidity sensor constructed from a planar spiral inductor and an interdigital capacitor was used here to demonstrate the proposed impedance matching method. It shows that the readout distance under the impedance matching is 1.5 times as long as that without the impedance matching. The impedance matching analysis gives in-depth insight into the LC sensor system behavior, and the results presented here suggest that the impedance matching method may be utilized the long distance readout of the scaled LC sensor application based on the S11 measurement.