Carlo Banfi

Prof. Dr. Carlo Banfi

Cardiac Vascular and Thoracic, Lung Transplantation, CHU UCL Namur, Namur, Wallonia, Belgium
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Circulation
Verified
Journal Article
Closed access
EBEric Van Belle
Eric Van Belle
FJFrançis Juthier
Françis Juthier
SSSophie Susen
Sophie Susen
AVAndré Vincentelli
André Vincentelli
BIBernard Iung
Bernard Iung
ETEmmanuel Teiger
Emmanuel Teiger
Background—: Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results—: TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions—: Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.

1 October 2016 in JACC
Verified
Journal Article
Closed access
MGMartine Gilard
Martine Gilard
HEHélène Eltchaninoff
Hélène Eltchaninoff
KCKarine Chevreul
Karine Chevreul
JFJean Fajadet
Jean Fajadet
PLPascal Leprince
Pascal Leprince
GVGérald Vanzetto
Gérald Vanzetto

1 December 2016 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
Carlo BanfiCarlo Banfi
Carlo Banfi
MPMatteo Pozzi
Matteo Pozzi
NSNils Siegenthaler
Nils Siegenthaler
MBMarie-Eve Brunner
Marie-Eve Brunner
DTDidier Tassaux
Didier Tassaux
RGRaphael Giraud
Raphael Giraud
The development of extracorporeal membrane oxygenation (ECMO) technology allows a new approach for the intensive care management of acute cardiac and/or respiratory failure in adult patients who are not responsive to conventional treatment. Current ECMO therapies provide a variety of options for the multidisciplinary teams who are involved in the management of these critically ill patients. In this regard, veno-venous ECMO (VV-ECMO) can provide quite complete respiratory support, even if this highly complex technique presents substantial risks, such as bleeding, thromboembolic events and infection. While VV-ECMO circuits usually include the cannulation of two vessels (double cannulation) in its classic configuration, the use of a single cannula is now possible for VV-ECMO support. Recently, experienced centers have employed more advanced approaches by cannulating three vessels (triple cannulation) which follows veno-arterio-venous (VAV) or veno-arterio-pulmonary-arterial cannulation (VAPa). However, ‘triple’ cannulation expands the field of application but increases the complexity of ECMO systems. In the present review, the authors focus on the indications for VV-ECMO, patient assessment prior to cannulation, the role of ultrasound-guided vessel puncture, double lumen single bicaval cannulations, and finally triple cannulation in VV-ECMO.

1 January 2016 in Journal of Cardiac Failure
Verified
Journal Article
Closed access
SMSylvestre Maréchaux
Sylvestre Maréchaux
RSRohan Samson
Rohan Samson
EBEric van Belle
Eric van Belle
JBJoke Breyne
Joke Breyne
JMJuliette de Monte
Juliette de Monte
PEPierre-Vladimir Ennezat
Pierre-Vladimir Ennezat

27 March 2015 in Circulation Research
Verified
Journal Article
Closed access
PDF file
EBEric Van Belle
Eric Van Belle
ARAntoine Rauch
Antoine Rauch
AVAndré Vincentelli
André Vincentelli
EJEmmanuelle Jeanpierre
Emmanuelle Jeanpierre
PLPaulette Legendre
Paulette Legendre
SSSophie Susen
Sophie Susen
Rationale:: Percutaneous aortic valve procedures are a major breakthrough in the management of patients with aortic stenosis. Residual gradient and residual aortic regurgitation are major predictors of midterm and long-term outcome after percutaneous aortic valve procedures. We hypothesized that (1) induction/recovery of high molecular weight (HMW) multimers of von Willebrand factor defect could be instantaneous after acute changes in blood flow, (2) a bedside point-of-care assay (platelet function analyzer-closure time adenine DI-phosphate [PFA-CADP]), reflecting HMW multimers changes, could be used to monitor in real-time percutaneous aortic valve procedures. Objective:: To investigate the time course of HMW multimers changes in models and patients with instantaneous induction/reversal of pathological high shear and its related bedside assessment. Methods and Results:: We investigated the time course of the induction/recovery of HMW multimers defects under instantaneous changes in shear stress in an aortic stenosis rabbit model and in patients undergoing implantation of a continuous flow left ventricular assist device. We further investigated the recovery of HMW multimers and monitored these changes with PFA-CADP in aortic stenosis patients undergoing transcatheter aortic valve implantation or balloon valvuloplasty. Experiments in the aortic stenosis rabbit model and in left ventricular assist device patients demonstrated that induction/recovery of HMW multimers occurs within 5 minutes. Transcatheter aortic valve implantation patients experienced an acute decrease in shear stress and a recovery of HMW multimers within minutes of implantation which was sustained overtime. In patients with residual high shear or with residual aortic regurgitation, no recovery of HMW multimers was observed. PFA-CADP profiles mimicked HMW multimers recovery both in transcatheter aortic valve implantation patients without aortic regurgitation (correction) and transcatheter aortic valve implantation patients with aortic regurgitation or balloon valvuloplasty patients (no correction). Conclusions:: These results demonstrate that variations in von Willebrand factor multimeric pattern are highly dynamic, occurring within minutes after changes in blood flow. It also demonstrates that PFA-CADP can evaluate in real time the results of transcatheter aortic valve procedures.

1 June 2016 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
Theodor FischleinTheodor Fischlein
Theodor Fischlein
BMBart Meuris
Bart Meuris
KHKavous Hakim-Meibodi
Kavous Hakim-Meibodi
MMMartin Misfeld
Martin Misfeld
TCThierry Carrel
Thierry Carrel
DWDaniel Wendt
Daniel Wendt