Iria Bravo

Dr. Iria Bravo

Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
TGTania García-Mendiola
Tania García-Mendiola
IBIria Bravo
Iria Bravo
JLJosé María López-Moreno
José María López-Moreno
FPFélix Pariente
Félix Pariente
RWReinhold Wannemacher
Reinhold Wannemacher
ELEncarnación Lorenzo
Encarnación Lorenzo

13 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
IBIria Bravo
Iria Bravo
MRMónica Revenga-Parra
Mónica Revenga-Parra
FPFélix Pariente
Félix Pariente
Encarnacion LorenzoEncarnacion Lorenzo
Encarnacion Lorenzo
Lactic acid is a relevant analyte in the food industry, since it affects the flavor, freshness, and storage quality of several products, such as milk and dairy products, juices, or wines. It is the product of lactose or malo-lactic fermentation. In this work, we developed a lactate biosensor based on the immobilization of lactate oxidase (LOx) onto N,N′-Bis(3,4-dihydroxybenzylidene) -1,2-diaminobenzene Schiff base tetradentate ligand-modified gold nanoparticles (3,4DHS–AuNPs) deposited onto screen-printed carbon electrodes, which exhibit a potent electrocatalytic effect towards hydrogen peroxide oxidation/reduction. 3,4DHS–AuNPs were synthesized within a unique reaction step, in which 3,4DHS acts as reducing/capping/modifier agent for the generation of stable colloidal suspensions of Schiff base ligand–AuNPs assemblies of controlled size. The ligand—in addition to its reduction action—provides a robust coating to gold nanoparticles and a catalytic function. Lactate oxidase (LOx) catalyzes the conversion of l-lactate to pyruvate in the presence of oxygen, producing hydrogen peroxide, which is catalytically oxidized at 3,4DHS–AuNPs modified screen-printed carbon electrodes at +0.2 V. The measured electrocatalytic current is directly proportional to the concentration of peroxide, which is related to the amount of lactate present in the sample. The developed biosensor shows a detection limit of 2.6 μM lactate and a sensitivity of 5.1 ± 0.1 μA·mM−1. The utility of the device has been demonstrated by the determination of the lactate content in different matrixes (white wine, beer, and yogurt). The obtained results compare well to those obtained using a standard enzymatic-spectrophotometric assay kit.

1 April 2022 in Bioelectrochemistry
Verified
Journal Article
Closed access
IBIria Bravo
Iria Bravo
MPMariana Prata
Mariana Prata
ÁTÁlvaro Torrinha
Álvaro Torrinha
CDCristina Delerue-Matos
Cristina Delerue-Matos
Encarnacion LorenzoEncarnacion Lorenzo
Encarnacion Lorenzo
Simone MoraisSimone Morais
Simone Morais

2 January 2018 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
IBIria Bravo
Iria Bravo
SRSamuel J. Rowley‐Neale
Samuel J. Rowley‐Neale
ELEncarnación Lorenzo
Encarnación Lorenzo
Craig BanksCraig Banks
Craig Banks

6 July 2017 in Nanomaterials
Verified
Journal Article
Open access
PDF file
FNFlavio Nucciarelli
Flavio Nucciarelli
IBIria Bravo
Iria Bravo
SGSergio Catalán Gómez
Sergio Catalán Gómez
LVLuis Vázquez
Luis Vázquez
Encarnacion LorenzoEncarnacion Lorenzo
Encarnacion Lorenzo
JPJose Luis Pau
Jose Luis Pau
New methods for the production of colloidal Ga nanoparticles (GaNPs) are introduced based on the evaporation of gallium on expendable aluminum zinc oxide (AZO) layer. The nanoparticles can be prepared in aqueous or organic solvents such as tetrahydrofuran in order to be used in different sensing applications. The particles had a quasi mono-modal distribution with diameters ranging from 10 nm to 80 nm, and their aggregation status depended on the solvent nature. Compared to common chemical synthesis, our method assures higher yield with the possibility of tailoring particles size by adjusting the deposition time. The GaNPs have been studied by spectrophotometry to obtain the absorption spectra. The colloidal solutions exhibit strong plasmonic absorption in the ultra violet (UV) region around 280 nm, whose width and intensity mainly depend on the nanoparticles dimensions and their aggregation state. With regard to the colloidal GaNPs flocculate behavior, the water solvent case has been investigated for different pH values, showing UV-visible absorption because of the formation of NPs clusters. Using discrete dipole approximation (DDA) method simulations, a close connection between the UV absorption and NPs with a diameter smaller than ~40 nm was observed.

1 May 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
IBIria Bravo
Iria Bravo
TGTania García-Mendiola
Tania García-Mendiola
MRM. Revenga-Parra
M. Revenga-Parra
FPF. Pariente
F. Pariente
ELE. Lorenzo
E. Lorenzo