Miriam Chacón-Mateos

Mrs. Miriam Chacón-Mateos

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JJJanani Venkatraman Jagatha
Janani Venkatraman Jagatha
AKAndré Klausnitzer
André Klausnitzer
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
BLBernd Laquai
Bernd Laquai
ENEvert Nieuwkoop
Evert Nieuwkoop
CSChristoph Schneider
Christoph Schneider
Over the last decade, manufacturers have come forth with cost-effective sensors for measuring ambient and indoor particulate matter concentration. What these sensors make up for in cost efficiency, they lack in reliability of the measured data due to their sensitivities to temperature and relative humidity. These weaknesses are especially evident when it comes to portable or mobile measurement setups. In recent years many studies have been conducted to assess the possibilities and limitations of these sensors, however mostly restricted to stationary measurements. This study reviews the published literature until 2020 on cost-effective sensors, summarizes the recommendations of experts in the field based on their experiences, and outlines the quantile-mapping methodology to calibrate low-cost sensors in mobile applications. Compared to the commonly used linear regression method, quantile mapping retains the spatial characteristics of the measurements, although a common correction factor cannot be determined. We conclude that quantile mapping can be a useful calibration methodology for mobile measurements given a well-elaborated measurement plan assures providing the necessary data.

22 December 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
CSCosima Stubenrauch
Cosima Stubenrauch
The use of low-cost sensors for air quality measurements has become very popular in the last few decades. Due to the detrimental effects of particulate matter (PM) on human health, PM sensors like photometers and optical particle counters (OPCs) are widespread and have been widely investigated. The negative effects of high relative humidity (RH) and fog events in the mass concentration readings of these types of sensors are well documented. In the literature, different solutions to these problems – like correction models based on the Köhler theory or machine learning algorithms – have been applied. In this work, an air pre-conditioning method based on a low-cost thermal dryer for a low-cost OPC is presented. This study was done in two parts. The first part of the study was conducted in the laboratory to test the low-cost dryer under two different scenarios. In one scenario, the drying efficiency of the low-cost dryer was investigated in the presence of fog. In the second scenario, experiments with hygroscopic aerosols were done to determine to which extent the low-cost dryer reverts the growth of hygroscopic particles. In the second part of the study, the PM10 and PM2.5 mass concentrations of an OPC with dryer were compared with the gravimetric measurements and a continuous federal equivalent method (FEM) instrument in the field. The feasibility of using univariate linear regression (ULR) to correct the PM data of an OPC with dryer during field measurement was also evaluated. Finally, comparison measurements between an OPC with dryer, an OPC without dryer, and a FEM instrument during a real fog event are also presented. The laboratory results show that the sensor with the low-cost dryer at its inlet measured an average of 64 % and 59 % less PM2.5 concentration compared with a sensor without the low-cost dryer during the experiments with fog and with hygroscopic particles, respectively. The outcomes of the PM2.5 concentrations of the low-cost sensor with dryer in laboratory conditions reveal, however, an excess of heating compared with the FEM instrument. This excess of heating is also demonstrated in a more in-depth study on the temperature profile inside the dryer. The correction of the PM10 concentrations of the sensor with dryer during field measurements by using ULR showed a reduction of the maximum absolute error (MAE) from 4.3 µg m−3 (raw data) to 2.4 µg m−3 (after correction). The results for PM2.5 make evident an increase in the MAE after correction: from 1.9 µg m−3 in the raw data to 3.2 µg m−3. In light of these results, a low-cost thermal dryer could be a cost-effective add-on that could revert the effect of the hygroscopic growth and the fog in the PM readings. However, special care is needed when designing a low-cost dryer for a PM sensor to produce FEM similar PM readings, as high temperatures may irreversibly change the sampled air by evaporating the most volatile particulate species and thus deliver underestimated PM readings. New versions of a low-cost dryer aiming at FEM measurements should focus on maintaining the RH at the sensor inlet at 50 % and avoid reaching temperatures higher than 40 ∘C in the drying system. Finally, we believe that low-cost dryers have a very promising future for the application of sensors in citizen science, sensor networks for supplemental monitoring, and epidemiological studies.

5 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
ERErika Remy
Erika Remy
ULUta Liebers
Uta Liebers
FHFrank Heimann
Frank Heimann
CWChristian Witt
Christian Witt
UVUlrich Vogt
Ulrich Vogt
Recent advances in sensor technology for air pollution monitoring open new possibilities in the field of environmental epidemiology. The low spatial resolution of fixed outdoor measurement stations and modelling uncertainties currently limit the understanding of personal exposure. In this context, air quality sensor systems (AQSSs) offer significant potential to enhance personal exposure assessment. A pilot study was conducted to investigate the feasibility of the NO2 sensor model B43F and the particulate matter (PM) sensor model OPC-R1, both from Alphasense (UK), for use in epidemiological studies. Seven patients with chronic obstructive pulmonary disease (COPD) or asthma had built-for-purpose sensor systems placed inside and outside of their homes at fixed locations for one month. Participants documented their indoor activities, presence in the house, window status, and symptom severity and performed a peak expiratory flow test. The potential inhaled doses of PM2.5 and NO2 were calculated using different data sources such as outdoor data from air quality monitoring stations, indoor data from AQSSs, and generic inhalation rates (IR) or activity-specific IR. Moreover, the relation between indoor and outdoor air quality obtained with AQSSs, an indoor source apportionment study, and an evaluation of the suitability of the AQSS data for studying the relationship between air quality and health were investigated. The results highlight the value of the sensor data and the importance of monitoring indoor air quality and activity patterns to avoid exposure misclassification. The use of AQSSs at fixed locations shows promise for larger-scale and/or long-term epidemiological studies.

28 August 2025 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
HGHéctor García-Salamero
Héctor García-Salamero
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
Over the past few decades, the study and the use of air quality sensors have significantly increased, leading to a wealth of experience and a deeper understanding of their strengths and limitations. This study aimed to develop and evaluate a methodology for PM2.5 and NO2 sensors to enhance sensor accuracy to a level suitable for epidemiological studies, where ensuring data quality is paramount. The performance evaluation of indoor and outdoor sensors was carried out during the co-location phase with reference-equivalent instruments (RIs), by calculating the relative expanded uncertainties (REUs) stated in the EU Air Quality Directive 2008/50/EC and the recently published EU Directive 2024/2881, target diagrams and common error metrics, before the deployment of the air quality sensor systems (AQSSs) in the houses of patients suffering from chronic obstructive pulmonary disease (COPD) or asthma, in Stuttgart (Germany). Regression and machine learning (ML) models for sensor calibration were tested during the co-location. Moreover, an original methodology was designed and evaluated to validate the sensor data during the deployment in the houses of the participants. The study found that indoor sensor calibration using artificially generated NO2 and aerosols does not ensure model transferability, emphasizing the need for training data that matches the intended deployment environment in terms of real patterns of concentration, particle composition and environmental conditions. Moreover, the effect of the aggregation time (1, 5, 10, and 15 min) on the performance of the calibration models was evaluated for NO2 sensors. Integrating metadata such as activity logs, window status, and data from official monitoring stations, as well as NO2 measurements with diffusion tubes, proved to be helpful for data validation and interpretation during the sensor deployment in the houses of the participants.

6 March 2025 in EGUsphere
Verified
Preprint
Open access
PDF file
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
HGHéctor García-Salamero
Héctor García-Salamero
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
Over the past few decades, the study and the use of air quality sensors have significantly increased, leading to a wealth of experience and a deeper understanding of their strengths and limitations. This study aimed to transcend the limitations by developing and evaluating a methodology for PM2.5 and NO2 sensors to enhance sensor accuracy to a level suitable for epidemiological studies, where ensuring data quality is paramount. The performance evaluation of indoor and outdoor sensors was carried out during the co-location phase with reference instruments (RIs), by calculating common error metrics, target diagrams and the relative expanded uncertainties (REUs) stated in the EU Air Quality Directive 2008/50/EC and the recently published EU Directive 2024/2881, before the deployment of the air quality sensor systems (AQSSs) in the houses of patients suffering from chronic obstructive pulmonary disease (COPD) or asthma in Stuttgart (Germany). Regression and machine learning models for sensor calibration were tested during the co-location. Moreover, an original methodology was designed and evaluated to validate the sensor data during the epidemiological study. The study found that indoor sensor calibration using artificially generated NO2 and aerosols does not ensure model transferability, emphasizing the need for training data that matches the intended deployment environment in terms of real patterns of concentration, particle composition and environmental conditions. Integrating metadata such as activity logs, window status, and data from official monitoring stations, proved essential for data validation and interpretation during the sensor deployment in the houses of the participants. Despite limitations at low pollutant levels, calibrated AQSSs are a promising tool to increase the ubiquity of epidemiological studies for low- and middle-income countries or regions where higher air pollutant concentrations are expected.

15 May 2023
Verified
Conference Paper
Open access
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
UVUlrich Vogt
Ulrich Vogt
BLBernd Laquai
Bernd Laquai
HGHéctor García-Salamero
Héctor García-Salamero
CWChristian Witt
Christian Witt
FHFrank Heimann
Frank Heimann
The increase in evidence on the adverse health effects of air pollution has been possible thanks to the advances in technology for air pollution monitoring and personal exposure. In this context, air quality sensors present a huge potential for enhancing long-term personal exposure prediction. In order to prove the potential of air sensors for health research, a pilot study with patients suffering from chronic obstructive pulmonary diseases or Asthma was carried out in Stuttgart (Germany) in cooperation with the University Hospital Charité in Berlin, and an outpatient pulmonary practice in Stuttgart.Prior to the pilot study, we first tested several sensor models for PM and NO2 in the laboratory as well as in the field. The sensors with the best performance were selected to build two different sensor boxes for indoor and outdoor measurements. Temperature and relative humidity sensors were also included in the boxes. To avoid the overestimation of the PM readings due to hygroscopic growth, a low-cost dryer was designed and evaluated for the PM sensor of the outdoor boxes (Chacón-Mateos et al. 2022).The measurements inside and outside the houses were carried out over 30 days. Passive sampling of NO2 was done additionally for quality assurance of the NO2 measurements. Participants completed spirometry, a questionnaire assessing respiratory symptoms, and a protocol of activities on a daily basis. The calibration and validation of the sensors were conducted two weeks before the start of the measurements. To perform the quality assurance, the sensor boxes for indoors were collocated in the laboratory, and the sensor boxes for outdoors in the field, together with reference-grade instruments. The PM2.5 concentrations were corrected using univariate linear regression whereas multilinear regression and machine learning algorithms were tested and applied to correct the raw data of the NO2 sensors.The sensor validations have shown that measuring low concentrations of PM2.5 and NO2 has higher expanded uncertainty, but high concentrations can be measured with expanded uncertainties that fulfill the Data Quality Objectives (DQO) set by the Air Quality Directives for indicative measurements. However, we also found a high unit-to-unit variability which means that model coefficients cannot be transferred from one sensor to another. We also recommend collocating NO2 passive samples close to the sensor boxes to determine whether or not the sensor is measuring within the expected range as the signal of some NO2 sensors drifted unexpectedly during the measurements in the houses of the patients.In conclusion, air sensors are not yet to be recommended to quantify the effects of low-level air pollution but they are a promising tool to increase the ubiquity of epidemiological studies for low- and middle-income countries where high air pollution is expected. Moreover, it is important to consider that in order to get actionable data with air sensors, a significant amount of time in sensor calibration should be invested.References:Chacón-Mateos, M., Laquai, B., Vogt, U., and Stubenrauch, C.: Evaluation of a low-cost dryer for a low-cost optical particle counter, Atmos. Meas. Tech., 15, 7395–7410, https://doi.org/10.5194/amt-15-7395-2022, 2022