Jakub Szymiczek

Mr. Jakub Szymiczek

AGH University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
ABAnna Barwińska-Małajowicz
Anna Barwińska-Małajowicz
RPRadosław Waldemar Pyrek
Radosław Waldemar Pyrek
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
JSJakub Szymiczek
Jakub Szymiczek
TPTeresa Piecuch
Teresa Piecuch
Economical and efficient use of energy is promoted around the world as a model of conscious care for the environment in which we live. A mere change of habits in the use of energy can reduce its costs by 5% to 15%, and investments in energy-saving technologies can pay for themselves after just a few years. This case study shows how significant steps can be taken in saving energy in the building of public utility buildings through deep thermomodernization using renewable energy sources—compressor heat pumps and photovoltaics. The article presents a comprehensive thermomodernization of a school building made according to Polish regulations. A detailed description of the tested object is given, and the calculation procedure is described. Next, the optimal investment variant and ex post analysis are described. The implementation of these projects significantly improved the energy efficiency of the building and generated final energy savings of 80%, which will significantly reduce the school’s operating costs. Thanks to the applied improvements, it was possible to save 72.30% of thermal energy in the building, which directly translates into lowering the building’s operating costs. The improvement of energy efficiency indicators ranges from 66% for usable energy to almost 85% for non-renewable primary energy. Furthermore, by reducing the demand for energy used in the building by nearly 74%, we see a reduction in CO2 emissions. The methods used were desk research and an extended case study of Poland, a country facing a number of problems related to energy prices during the energy crisis. In this article, we identify the challenges faced by Poland due to its geopolitical situation, and the solutions introduced to the difficult situation in the energy market come in the form of the thermomodernization of buildings. It was on this basis that Poland was selected as a case study.

2 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
PMPiotr Michalak
Piotr Michalak
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
JSJakub Szymiczek
Jakub Szymiczek
Thermal refurbishment of buildings results in certain energy, financial, and environmental effects. Such investments are financially supported in Poland after meeting the legally defined conditions of thermal protection and energy consumption. This paper presents a complex thermal modernization of a school building, performed by following Polish regulations. A detailed description of the studied object was given, and the calculation procedure was described. Then an optimal variant of an investment and an ex-post analysis were described. Simple payback time (SPBT) of modernization measures was from 15.8 years (insulation of the ceiling under the unheated attic) to 87 years for insulation of the wooden external wall, with 35.6 years for the whole project, which is shorter than the predicted lifespan of the whole building (50–70 years). Annual calculated heating demand decreased from 464.78 to 168.73 GJ, resulting in the primary energy consumption indicator (EP) of 484.44 and 129.46 kWh/m2, respectively. Thermal refurbishment with the replacement of an old boiler into a new wood-pellet one resulted in a significant reduction of SO2 and dust emissions from 451 to 27.5 kg and from 399 to 13 kg, respectively.

2 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
JSJakub Szymiczek
Jakub Szymiczek
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
PMPiotr Michalak
Piotr Michalak
The use of renewables in heat production requires methods to overcome the issue of asynchronous heat load and energy production. The most effective method for analyzing the intricate thermal dynamics of an existing building is through transient simulation, utilizing real-world weather data. This approach offers a far more nuanced understanding than static calculations, which often fail to capture the dynamic interplay of environmental factors and building performance. Transient simulations, by their nature, model the building’s thermal behavior over time, reflecting the continuous fluctuations in temperature, solar radiation, and wind speed. Leveraging actual meteorological data enables the simulation model to faithfully capture system dynamics under realistic operational scenarios. This is crucial for evaluating the effectiveness of heating, ventilation, and air conditioning (HVAC) systems, identifying potential energy inefficiencies, and assessing the impact of various energy-saving measures. The simulation can reveal how the building’s thermal mass absorbs and releases heat, how solar gains influence indoor temperatures, and how ventilation patterns affect heat losses. In this paper, a household heating system consisting of an air source heat pump, PV, and buffer tank is simulated and analyzed. The 3D model accurately represents the building’s geometry and thermal properties. This virtual representation serves as the basis for calculating heat losses and gains, considering factors such as insulation levels, window characteristics, and building orientation. The approach is based on the calculation of building heat load based on a 3D model and EN ISO 52016-1 standard. The heat load is modeled based on air temperature and sun irradiance. The heating system is modeled in EBSILON professional 16.00 software for the calculation of transient 10 min time step heat production during the heating season. The results prove that a buffer tank with the right heat production control system can efficiently increase the auto consumption of self-produced PV electric energy, leading to a reduction in environmental effects and higher economic profitability.

20 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
PMPiotr Michalak
Piotr Michalak
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
JSJakub Szymiczek
Jakub Szymiczek
Multifamily buildings account for about half of all residential buildings in Poland and about 70% of the urban population live in them. Most of them require thermal refurbishment. Evaluation of a building’s energy performance with the use of correlation models has been very rarely used in relation to buildings in Poland. This method is simple, fast and can improve the decision process on thermal modernisation. It is especially important at the pre-design stage of planned investments. This paper presents an attempt to develop correlations that could be used in the energy assessment of multifamily buildings. For this purpose a dataset containing of 29 audits of multifamily buildings was used. The statistical analysis was performed for buildings before and after planned refurbishment. Obtained relationships showed strong correlation between thermal demand for space heating or domestic hot water and ventilation airflow and thermal transmittance of windows (R2 > 0.6). After designed modernisation the number of strong correlations decreased. Energy for domestic hot water was correlated with the number of inhabitants (R2 = 0.6). Energy for space heating was correlated with the number of users and heated volume of a building.

30 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
JSJakub Szymiczek
Jakub Szymiczek
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
MBMarian Banaś
Marian Banaś
PJPrzemysław Jura
Przemysław Jura
The development of district heating systems results in a search for alternative heat sources. One of these is low-enthalpy geothermic energy, more available than traditional geothermal energy. However, utilization of these resources is difficult, due to the low quality of the produced heat. To utilize them, the heat pump system can be used. Such a system was designed for this case study of a city in a region of the Polish Lowlands. The data necessary for the design came from the project of the borehole and operational parameters of the existing heating plant. Four heat pump-cycle designs were proposed, modeled, and simulated using Ebsilon software. Afterward, the designs were optimized to achieve maximum coefficient of performance (COP) value. As a result of the simulation, the efficiency of each design was determined and the seasonal COP value was calculated with the annual measured heat demand of the plant. The system based on the cascade design proved the most efficient, with a seasonal COP of 7.19. The seasonal COP for the remaining basic, subcooling, and regenerator variants was 5.61, 3.73, and 5.60, respectively. The annual heat production of the designed system (22,196 MWh) was calculated based on the thermal power of the designed system and historical demand data. This paper presents a simulation methodology for assessment of the efficiency and feasibility of a heat pump system in district heating.

21 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
ABAnna Barwińska-Małajowicz
Anna Barwińska-Małajowicz
MBMarian Banaś
Marian Banaś
TPTeresa Piecuch
Teresa Piecuch
RPRadosław Waldemar Pyrek
Radosław Waldemar Pyrek
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
JSJakub Szymiczek
Jakub Szymiczek
Zero-emission buildings, which do not emit CO2 or other greenhouse gases throughout their entire life cycle, play a crucial role in sustainable development and the fight against climate change. Achieving carbon neutrality in construction requires considering emissions associated with material production, construction, operation, as well as demolition and disposal. These buildings utilize energy-efficient technologies, renewable energy sources, and low-carbon materials, minimizing their environmental impact. The building sector accounts for a significant percentage of global greenhouse gas emissions, making it a key area for climate action. In Poland, where aging and energy-inefficient buildings prevail, the need for a transition towards zero-emission buildings is particularly urgent. This paper assesses the feasibility and hurdles of retrofitting existing buildings to achieve zero emissions by utilizing renewable energy systems like solar photovoltaic and heat pump technologies. The publication discusses the technical, economic, and legal aspects of this transformation, with particular emphasis on the Polish context and available support programs. The purpose of this publication is to disseminate practical knowledge and foster innovation among architects, investors, and decision-makers engaged in the development of a sustainable built environment. A key example is Net Zero Energy Buildings (NZEBs), which generate as much energy as they consume over a year through technologies such as photovoltaic panels, solar collectors, and heat pumps. NZEBs combine effective insulation, energy-efficient systems, and smart energy management to minimize consumption, and may even produce excess energy that feeds back into the grid. Despite challenges in construction and maintenance, the increasing adoption of zero-emission and NZEBs worldwide reflects their long-term ecological, economic, and health benefits. The focus of this publication is to analyze the potential for transforming standard buildings, as defined by current regulations, into zero-emission buildings powered entirely by renewable energy sources. This case study analyzes the energy potential of a residential building located in Krakow, Poland. The building’s energy efficiency potential was assessed through computer simulations using Audytor OZC software (version 7.0 Pro, Sankom), taking into account local climate conditions and building standards. The study analyzed the impact of various strategies, such as upgrading thermal insulation, using energy-efficient windows, and installing photovoltaic panels, on energy consumption and CO2 emissions.