Krzysztof Szczotka

Dr. Krzysztof Szczotka

Department of Power Systems and Environmental ..., AGH University of Krakow, Kraków, Małopolskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JZJacek Zimny
Jacek Zimny
PMPiotr Michalak
Piotr Michalak
SBSebastian Bielik
Sebastian Bielik
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka

11 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
ABAnna Barwińska-Małajowicz
Anna Barwińska-Małajowicz
RPRadosław Waldemar Pyrek
Radosław Waldemar Pyrek
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
JSJakub Szymiczek
Jakub Szymiczek
TPTeresa Piecuch
Teresa Piecuch
Economical and efficient use of energy is promoted around the world as a model of conscious care for the environment in which we live. A mere change of habits in the use of energy can reduce its costs by 5% to 15%, and investments in energy-saving technologies can pay for themselves after just a few years. This case study shows how significant steps can be taken in saving energy in the building of public utility buildings through deep thermomodernization using renewable energy sources—compressor heat pumps and photovoltaics. The article presents a comprehensive thermomodernization of a school building made according to Polish regulations. A detailed description of the tested object is given, and the calculation procedure is described. Next, the optimal investment variant and ex post analysis are described. The implementation of these projects significantly improved the energy efficiency of the building and generated final energy savings of 80%, which will significantly reduce the school’s operating costs. Thanks to the applied improvements, it was possible to save 72.30% of thermal energy in the building, which directly translates into lowering the building’s operating costs. The improvement of energy efficiency indicators ranges from 66% for usable energy to almost 85% for non-renewable primary energy. Furthermore, by reducing the demand for energy used in the building by nearly 74%, we see a reduction in CO2 emissions. The methods used were desk research and an extended case study of Poland, a country facing a number of problems related to energy prices during the energy crisis. In this article, we identify the challenges faced by Poland due to its geopolitical situation, and the solutions introduced to the difficult situation in the energy market come in the form of the thermomodernization of buildings. It was on this basis that Poland was selected as a case study.

1 August 2015 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JZJacek Zimny
Jacek Zimny
PMPiotr Michalak
Piotr Michalak
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka

2 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
PMPiotr Michalak
Piotr Michalak
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
JSJakub Szymiczek
Jakub Szymiczek
Thermal refurbishment of buildings results in certain energy, financial, and environmental effects. Such investments are financially supported in Poland after meeting the legally defined conditions of thermal protection and energy consumption. This paper presents a complex thermal modernization of a school building, performed by following Polish regulations. A detailed description of the studied object was given, and the calculation procedure was described. Then an optimal variant of an investment and an ex-post analysis were described. Simple payback time (SPBT) of modernization measures was from 15.8 years (insulation of the ceiling under the unheated attic) to 87 years for insulation of the wooden external wall, with 35.6 years for the whole project, which is shorter than the predicted lifespan of the whole building (50–70 years). Annual calculated heating demand decreased from 464.78 to 168.73 GJ, resulting in the primary energy consumption indicator (EP) of 484.44 and 129.46 kWh/m2, respectively. Thermal refurbishment with the replacement of an old boiler into a new wood-pellet one resulted in a significant reduction of SO2 and dust emissions from 451 to 27.5 kg and from 399 to 13 kg, respectively.

22 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
ABAnna Barwińska-Małajowicz
Anna Barwińska-Małajowicz
MKMiroslava Knapková
Miroslava Knapková
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
MMMiriam Martinkovicovs
Miriam Martinkovicovs
RPRadosław Waldemar Pyrek
Radosław Waldemar Pyrek
Improving energy efficiency includes a number of measures implemented as part of the greening of the energy industry, which in turn is a prerequisite for the creation of a sustainable energy industry to ensure energy and environmental security for the world. Despite the adoption of the EU directives on energy efficiency, there is still insufficient public awareness in this area in Poland and Slovakia. This is particularly surprising because improving energy efficiency not only brings national and global benefits, but also has a significant impact on the well-being of individuals and households. The main purpose of the paper is to analyze the national policies of Poland and Slovakia, which are based on the European Directive 2012/27/EU on energy efficiency, and which introduce new measures aimed not only at increasing energy efficiency, but also at increasing the well-being of households and individuals. Methods of desk research and content analysis were used. The current situation in both countries is illustrated by case studies that document the administrative process (Slovakia) and the calculation of energy savings (Poland) when using renewable energy sources in the case of family houses.

2 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
JSJakub Szymiczek
Jakub Szymiczek
Krzysztof SzczotkaKrzysztof Szczotka
Krzysztof Szczotka
PMPiotr Michalak
Piotr Michalak
The use of renewables in heat production requires methods to overcome the issue of asynchronous heat load and energy production. The most effective method for analyzing the intricate thermal dynamics of an existing building is through transient simulation, utilizing real-world weather data. This approach offers a far more nuanced understanding than static calculations, which often fail to capture the dynamic interplay of environmental factors and building performance. Transient simulations, by their nature, model the building’s thermal behavior over time, reflecting the continuous fluctuations in temperature, solar radiation, and wind speed. Leveraging actual meteorological data enables the simulation model to faithfully capture system dynamics under realistic operational scenarios. This is crucial for evaluating the effectiveness of heating, ventilation, and air conditioning (HVAC) systems, identifying potential energy inefficiencies, and assessing the impact of various energy-saving measures. The simulation can reveal how the building’s thermal mass absorbs and releases heat, how solar gains influence indoor temperatures, and how ventilation patterns affect heat losses. In this paper, a household heating system consisting of an air source heat pump, PV, and buffer tank is simulated and analyzed. The 3D model accurately represents the building’s geometry and thermal properties. This virtual representation serves as the basis for calculating heat losses and gains, considering factors such as insulation levels, window characteristics, and building orientation. The approach is based on the calculation of building heat load based on a 3D model and EN ISO 52016-1 standard. The heat load is modeled based on air temperature and sun irradiance. The heating system is modeled in EBSILON professional 16.00 software for the calculation of transient 10 min time step heat production during the heating season. The results prove that a buffer tank with the right heat production control system can efficiently increase the auto consumption of self-produced PV electric energy, leading to a reduction in environmental effects and higher economic profitability.