Ehsan Eftekhari-Zadeh

Dr. Ehsan Eftekhari-Zadeh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SHSiavash Hosseini
Siavash Hosseini
OTOsman Taylan
Osman Taylan
MAMona Abusurrah
Mona Abusurrah
Thangarajah AkilanThangarajah Akilan
Thangarajah Akilan
Ehsan NazemiEhsan Nazemi
Ehsan Nazemi
GRGholam Hossein Roshani
Gholam Hossein Roshani
Measuring fluid characteristics is of high importance in various industries such as the polymer, petroleum, and petrochemical industries, etc. Flow regime classification and void fraction measurement are essential for predicting the performance of many systems. The efficiency of multiphase flow meters strongly depends on the flow parameters. In this study, MCNP (Monte Carlo N-Particle) code was employed to simulate annular, stratified, and homogeneous regimes. In this approach, two detectors (NaI) were utilized to detect the emitted photons from a cesium-137 source. The registered signals of both detectors were decomposed using a discrete wavelet transform (DWT). Following this, the low-frequency (approximation) and high-frequency (detail) components of the signals were calculated. Finally, various features of the approximation signals were extracted, using the average value, kurtosis, standard deviation (STD), and root mean square (RMS). The extracted features were thoroughly analyzed to find those features which could classify the flow regimes and be utilized as the inputs to a network for improving the efficiency of flow meters. Two different networks were implemented for flow regime classification and void fraction prediction. In the current study, using the wavelet transform and feature extraction approach, the considered flow regimes were classified correctly, and the void fraction percentages were calculated with a mean relative error (MRE) of 0.4%. Although the system presented in this study is proposed for measuring the characteristics of petroleum fluids, it can be easily used for other types of fluids such as polymeric fluids.

27 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAbdullah K. Alanazi
Abdullah K. Alanazi
SASeyed Mehdi Alizadeh
Seyed Mehdi Alizadeh
KNKarina Nurgalieva
Karina Nurgalieva
SNSlavko Nešić
Slavko Nešić
JGJohn William Grimaldo Guerrero
John William Grimaldo Guerrero
INIgor M. Narozhnyy
Igor M. Narozhnyy
One of the factors that significantly affects the efficiency of oil and gas industry equipment is the scales formed in the pipelines. In this innovative, non-invasive system, the inclusion of a dual-energy gamma source and two sodium iodide detectors was investigated with the help of artificial intelligence to determine the flow pattern and volume percentage in a two-phase flow by considering the thickness of the scale in the tested pipeline. In the proposed structure, a dual-energy gamma source consisting of barium-133 and cesium-137 isotopes emit photons, one detector recorded transmitted photons and a second detector recorded the scattered photons. After simulating the mentioned structure using Monte Carlo N-Particle (MCNP) code, time characteristics named 4th order moment, kurtosis and skewness were extracted from the recorded data of both the transmission detector (TD) and scattering detector (SD). These characteristics were considered as inputs of the multilayer perceptron (MLP) neural network. Two neural networks that were able to determine volume percentages with high accuracy, as well as classify all flow regimes correctly, were trained.

2 July 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
MAMohammed Alamoudi
Mohammed Alamoudi
MSMohamadAmir Sattari
MohamadAmir Sattari
MBMohammad Balubaid
Mohammad Balubaid
EEEhsan Eftekhari-Zadeh
Ehsan Eftekhari-Zadeh
Ehsan NazemiEhsan Nazemi
Ehsan Nazemi
EKEl Mostafa Kalmoun
El Mostafa Kalmoun
Scale deposits can reduce equipment efficiency in the oil and petrochemical industry. The gamma attenuation technique can be used as a non-invasive effective tool for detecting scale deposits in petroleum pipelines. The goal of this study is to propose a dual-energy gamma attenuation method with radial basis function neural network (RBFNN) to determine scale thickness in petroleum pipelines in which two-phase flows with different symmetrical flow regimes and void fractions exist. The detection system consists of a dual-energy gamma source, with Ba-133 and Cs-137 radioisotopes and two 2.54-cm × 2.54-cm sodium iodide (NaI) detectors to record photons. The first detector related to transmitted photons, and the second one to scattered photons. The transmission detector recorded two signals, which were the counts under photopeak of Ba-133 and Cs-137 with the energy of 356 keV and 662 keV, respectively. The one signal recorded in the scattering detector, total counts, was applied to RBFNN as the inputs, and scale thickness was assigned as the output.

9 May 2021 in Processes
Verified
Journal Article
Open access
PDF file
GRGholam Hossein Roshani
Gholam Hossein Roshani
Peshawa Jamal Muhammad AliPeshawa Jamal Muhammad Ali
Peshawa Jamal Muhammad Ali
SMShivan Mohammed
Shivan Mohammed
Robert HanusRobert Hanus
Robert Hanus
LALokman Abdulkareem
Lokman Abdulkareem
EKEl Mostafa Kalmoun
El Mostafa Kalmoun
Radiation-based instruments have been widely used in petrochemical and oil industries to monitor liquid products transported through the same pipeline. Different radioactive gamma-ray emitter sources are typically used as radiation generators in the instruments mentioned above. The idea at the basis of this research is to investigate the use of an X-ray tube rather than a radioisotope source as an X-ray generator: This choice brings some advantages that will be discussed. The study is performed through a Monte Carlo simulation and artificial intelligence. Here, the system is composed of an X-ray tube, a pipe including fluid, and a NaI detector. Two-by-two mixtures of four various oil products with different volume ratios were considered to model the pipe’s interface region. For each combination, the X-ray spectrum was recorded in the detector in all the simulations. The recorded spectra were used for training and testing the multilayer perceptron (MLP) models. After training, MLP neural networks could estimate each oil product’s volume ratio with a mean absolute error of 2.72 which is slightly even better than what was obtained in former studies using radioisotope sources.

7 January 2023 in Axioms
Verified
Journal Article
Open access
PDF file
Aryan VeisiAryan Veisi
Aryan Veisi
MSmohammad hossein shahsavari
mohammad hossein shahsavari
GRGholam Hossein Roshani
Gholam Hossein Roshani
EEEhsan Eftekhari-Zadeh
Ehsan Eftekhari-Zadeh
Ehsan NazemiEhsan Nazemi
Ehsan Nazemi
One of the most severe problems in power plants, petroleum and petrochemical industries is the accurate determination of phase fractions in two-phase flows. In this paper, we carried out experimental investigations to validate the simulations for water–air, two-phase flow in an annular pattern. To this end, we performed finite element simulations with COMSOL Multiphysics, conducted experimental investigations in concave electrode shape and, finally, compared both results. Our experimental set-up was constructed for water–air, two-phase flow in a vertical tube. Afterwards, the simulated models in the water–air condition were validated against the measurements. Our results show a relatively low relative error between the simulation and experiment indicating the validation of our simulations. Finally, we designed an Artificial Neural Network (ANN) model in order to predict the void fractions in any two-phase flow consisting of petroleum products as the liquid phase in pipelines. In this regard, we simulated a range of various liquid–gas, two-phase flows including crude oil, oil, diesel fuel, gasoline and water using the validated simulation. We developed our ANN model by a multi-layer perceptron (MLP) neural network in MATLAB 9.12.0.188 software. The input parameters of the MLP model were set to the capacitance of the sensor and the liquid phase material, whereas the output parameter was set to the void fraction. The void fraction was predicted with an error of less than 2% for different liquids via our proposed methodology. Using the presented novel metering system, the void fraction of any annular two-phase flow with different liquids can be precisely measured.

1 January 2022 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
EEEhsan Eftekhari-Zadeh
Ehsan Eftekhari-Zadeh
MBM. S. Blümcke
M. S. Blümcke
ZSZhanna Samsonova
Zhanna Samsonova
RLR. Loetzsch
R. Loetzsch
IUI. Uschmann
I. Uschmann
Christian SpielmannChristian Spielmann
Christian Spielmann
We report here on the results of comparative experimental measurements of laser energy absorption in a bulk and different morphology nanowire arrays interacting with relativistically intense, ultra-high temporal contrast femtosecond laser pulses. We compare polished, flat bulk samples with vertically and randomly oriented nanowires made of ZnO semiconductor material. The optical absorption of the 45° incident laser pulses of ∼40 fs duration with a central wavelength of 400 nm at intensities above 1019Wcm2 was determined using an integrating Ulbricht sphere. We demonstrate an almost twofold enhancement of absorption in both nanowire morphologies with an average of (79.6±1.9 )% in comparison to the flat bulk sample of (45.8±1.9 )%. The observed substantially enhanced absorption in nanowire arrays is also confirmed by high-resolution x-ray emission spectroscopy. The spectral analysis of the K-shell x-ray emission lines revealed that the He-like resonance line emission from highly ionized Zn (Zn28+) is only present in the case of nanowire arrays, whereas, for the flat bulk samples, only neutral and low charge states were observed. Our numerical simulations, based on radiative-collisional kinetic code FLYCHK, well reproduce the measured He-like emission spectrum and suggest that high charge state observed in nanowire arrays is due to substantially higher plasma temperature. Our results, which were measured for the first time with femtosecond laser pulses, can be used to benchmark theoretical models and numerical codes for the relativistic interaction of ultrashort laser pulses with nanowires.